AutoCAD Civil 3D :: Changing Pipe Sizes
Aug 23, 2012
I know how to edit the pipe part properties to change a pipe from the size indicated in my parts list to another common size for the particular material specified. However, I've run into a non-standard size that is not in the dropdown menu, how can I add another size to the list?
Basically, I need a 1.5" on the list in the attached screep cap.
View 3 Replies
ADVERTISEMENT
Oct 22, 2013
I am trying to change the sizes of markers individually. When I change the marker of one, it changes for all of them. I think this has to do with the point groups. I am able to add all points to a new group but I cant specify which markers i want in that group.
View 2 Replies
View Related
Dec 11, 2012
Version Civil 3D 2013....
A pipe network has been created & labeled. All pipes labeled correctly except one. The material for 15", 18", 24" RCP pipes labeled "RCP" but all the 12" pipes labeled "Reinforced Concrete Pipe". So I know I need to change the Material of the 12" pipe to read "RCP". I was hoping to just go to Pipe Properties & change it there for this dwg but it doesn't change.
I was thinking it might be in the part xml file but why would some label "RCP" and the 12" didn't? The Parts Catolog used in this dwg is the default from Autodesk. Also, in the Part List, Material is greyed out. That's the first place I went to change the Material.
View 9 Replies
View Related
Nov 14, 2013
How do you change the pressure pipe description ex. Ductile Iron to DIP? Or can you change it at all?
View 1 Replies
View Related
May 7, 2013
I have a profile with pipes and labels. I need to change the vertical exaggeration.
I can change the profile view style graphic exaggeration, but the pipes and associated labels do not rescale. Is there a way to force the pipes and labels to update to the new vertical exaggeration?
View 2 Replies
View Related
Nov 22, 2013
I copied the pressure pipe catalogs to our local network and in C3D 2014 set the catalog to the network location.
When I close C3D and reopen, it reverts back to the original catalog location on my C drive.
Setting a different location for regular pipe networks works fine.
Is there something I'm missing or does this method not work for pressure networks.
Civil3D 2014 SP1
Win 7 Professional - 64-bit
HP Z400
Xeon W3550 @ 3.07Ghz
24GB of RAM
Nvidia GeForce GTX 760
View 3 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Nov 20, 2013
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
View 1 Replies
View Related
Sep 25, 2012
I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.
View 1 Replies
View Related
Jan 8, 2014
One of the things I seem to struggle with is being able to depict a single pipe when it needs to be shown in one profile as a crossing pipe, and another profile where you you show a lenghwise slice through the pipe. I end up tracing the pipe with eliptical objects where I'm cutting across the pipe and setting up more for the lengthwise/sideview of the pipe. Is there a way to have two different styles for the same pipe, one for a cross cut and one for a lengthwise slice?
View 1 Replies
View Related
Nov 26, 2013
is there a way to include the pipe min/max cover as part of the str/pipe label?
Civil 3D 2013 SP1, Win 7-64 bit
12GB RAM
View 3 Replies
View Related
Jun 20, 2012
Using Network Layout Tools, can you attach a pipe to a structure in a different Pipe Network? 2013 Civil 3D
View 6 Replies
View Related
Oct 2, 2013
I am creating a web page using CS6 Photo Shop and DreamWeaver. I want the photos to be 900 px wide and 294 px high. When I do this it distorts the image by making it look short and squat. Is there a way to change the width and height but keep the image looking like the original?
View 2 Replies
View Related
Jun 27, 2012
I'm baffled. I do 99.9% of my photo work in Lightroom and then export to jpg. On the rare occasion when I need to remove something from a photo (a fly or leash), I have been using PSP version 9 because I already have it.
However, this morning I opened an 8 Mb jpgs file, did my editing and just saved it (no save as or resizing), and now the file is only 2 Mb.
What the heck? [URL]....
View 2 Replies
View Related
Oct 26, 2011
I am trying to load multiple Text Sizes into AutoCAD Civil 3D 2012 so that I can have a list of the standard text sizes (3/32", 3/16", 1/4", 3/8") to choose from the Annotation tab > Text Group > Annotation Text Height drop down list, instead of having to type them in each time.
At first I thought that I could just add the different text sizes using the TEXTSIZE variable command into my drawing template file, but apparently the Text Sizes entered are only retained for that particular session of AutoCAD Civil 3D. Is there perhaps some other system variable that controls this setting being retained for more than one session??
Then I thought I could just create a program to load the sizes. I originally tried creating a C# .NET program to load the text sizes, but ran into a problem. I then I tried creating another version of a C# program, as well as an AutoLISP script, thinking that it was perhaps some limitation to my approach (which still may be the case). But I still keep running into the same problem. The problem is that only the last text size specified is actually entered into the list of available text sizes. The other text size values appear to be processed but are not retained in the Annotation Text Height drop down list.
The following is my first attempt with C#:
using Autodesk.AutoCAD.ApplicationServices;
using Autodesk.AutoCAD.Runtime;
public class CreateTextSizes : Autodesk.AutoCAD.Runtime.IExtensionApplication
{
public void Initialize()
{
// Create following Text Sizes: 0.09375 (3/32"), 0.1975 (3/16"), 0.25 (1/4"), 0.375 (3/8")
[code].....
The following is my attempt with AutoLISP:
(defun c:LOADTEXTSIZES()
(Command "TEXTSIZE" 0.09375)
(Command "TEXTSIZE" 0.1975)
(Command "TEXTSIZE" 0.025)
(Command "TEXTSIZE" 0.375)
(Command "TEXTSIZE" 0.09375)
)
View 1 Replies
View Related
Sep 9, 2013
On the Marker Tab of my point style, I set the Marker Size to 0.05".
Then on the Summary Tab, under the Marker Node, the Point Marker Size shows 0.004". If I change that to 0.05, like I have it on the Marker Tab, the point marker becomes huge. Why aren't these two settings the same?
Another question. When I reduce the Marker and Label sizes, the label doesn't "suck in" to the marker. How can I bring the label closer to the marker without dragging it?
HP DV7 Laptop
Intel Core i7-3820QM 3rd Generation Quad Core 2.7 GHZ CPU
16 GB DDR3 RAM ( 2 DIMM ) / 180 GB SSD
Nvidia GeForce 650M Graphics w/2 GB Memory
Windows 7 Professional 64 bit / AutoCAD Civil 3D 2014
View 2 Replies
View Related
Nov 1, 2013
I created a pipe rule and applied it to my 6" HDPE pipe in my parts list. The rule is followed close but not exact. Here it is:
I created a "cover only" rule for my 6" HDPE pipe. I have the maximum and minimum cover set to 3.50'. I have it the same so it will draw my pipe 3.50' deep. I don't want it to vary. It for drawing in existing underground power so when we cut profiles and sections the existing power shows up. We want it to show up 3.50' deep. I created a label style for my pipe that tells me start cover and end cover of the pipe so I can see it right there on the screen. The numbers range from 3.50' deep to 4.70' deep.
Why does the pipe not get drawn in exactly 3.50' deep?
View 4 Replies
View Related
Apr 20, 2013
When I create a new pressure network in 2014 - I have only Tees & Elbows available - Where are crosses? I need a 4-way cross at an intersection, C3D seems to include just the other two types I listed.
View 3 Replies
View Related
Jul 31, 2012
I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.
This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.
View 7 Replies
View Related
Sep 26, 2013
Any way to label a pipe part way between structures? I would like to be able to label a sanitary line where a service ties in with the main line invert.
C3D 2013
View 7 Replies
View Related
Feb 1, 2013
My boss has designed a gravity project that has 21" PVC. Civil 3D 2010 only has 20" PVC, not 21". He basically said 21" PVC exists (JM Eagle) so make it happen. So how exactly can I add a new size to the Parts Catalog under PVC?
Windows 7 Prof w/ SP1, 64bit, Xeon 3Ghz, 16GB
Civil 3D 2013
View 1 Replies
View Related
May 31, 2013
I'm in the process of creating content for "pressure Pipe networks". I have created a number of pipes (HDPE, PVC and steel, sizes ranging from 20mm to 200mm). I have also created a number of Tees (Equal and reducing).
My question is.
If you draw in pressure pipe say 90mm ø and the insert a fitting say a 90x75x90 reducing Tee into the line. Then you wish to extend the pipe from the 75mm ø branch, it does not pick up it should be a 75mm pipe but defaults back to the setting (90mm) that you drew the original pipe line in, you have to change the default pipe type to 75 before extending the 75mm pipe from the Tee.
Below I have included a couple of screen shots.
View 2 Replies
View Related
Jan 7, 2014
I'm drawing existing SD pipes and trying to put in rim and inverts of the existing structures. Sometimes it won't let me raise an invert to where it really is. It only let's me raise it so far. It may be a rule but it doesn't seem to be a rule I can change.
View 4 Replies
View Related
Mar 22, 2012
I have multiple profile views with a pipe network. In a number of cases, I have a pipe that extends to the end of one profile view and continues on the next. I can label the pipe on one profile but not on the other. Is there a way to add two labels to the same pipe - one label on one profile view and another label on the other profile?
View 2 Replies
View Related
Mar 2, 2013
Trying to make some changes to improve reading. The pipes are going to center of structure and would like to change the appearance but maintain the lenght to the center or in last case to the structure wall.
The image explains the 'problem'. Red line should be the correct appearance
There is a way to correct the position?
View 8 Replies
View Related
Mar 19, 2012
I've set the start and end locations to be at the structure inner wall and applied rules but the invert elevation is still as if the pipe ended at the center of the structure. Did I miss something or does this not do what I think it does?
View 1 Replies
View Related
Apr 10, 2013
I have lost the ability to create a pipe network in a single drawing. Sorta. I can create a pipe network, and label it, and see it in my toolspace, but it won't display it for any style in any format. I can bring in a data reference and label those, but can not see pipe or structure outlines or anything to that end. I have tried to recover, audit, purge. I am at the end, currently creating the pipe network, data referencing it in, and then just drawing lines between the labels.
View 9 Replies
View Related
Oct 25, 2012
I'm using C3D 09 with all the updates. OK, now that those are addressed, I am having an issue with my pipe hatching dissappearing when I connect it to a structure. See the two attached pics for clarity.
View 4 Replies
View Related
Apr 3, 2012
how do I use Civil 3D to do basic pipe analysis computations? For example, I give it the slope, material, etc. and it spits out the flow velocity, flow depth, slope min, etc.
All I want for now is a basic tool for sizing pipes without all the bells, loops & whistles. I can learn the fancy pipe networking stuff later.
View 5 Replies
View Related
Apr 18, 2013
When labeling pipes, the lengths and stations do not always match. this appears to be related to a rounding issue. for example, the first pipe may start at 0+00 and have a length of 50.69167397’. The reported station in the structure label (using “normal rounding”) is naturally 0+50.69, as anticipated. The upstream pipe has a length of 43.36435901’, resulting in a total length from 0+00 of 94.05603298, resulting in a station of 0+94.06. However, the rounded values of the lengths (c’mon, nobody reports lengths to the 100-millionth) labeled on the pipes (50.69’ and 43.36’) total an expected station of 0+94.05.
I have tried all manners of “rounding” in the label styles, but it always falls down in one situation or another. I have also tried setting in the network and pipe “Feature Settings” for distance to a locked accuracy of 2 decimal places, but that does nto seem to do it either.
So, the question is, is there a way to resolve this issue without having to move one of the structures 0.001’ to resolve the mathematical parallax?
View 6 Replies
View Related
May 10, 2012
What is the best way to edit the parameters of a pipe (slope, ie, size) once you have it drawn?
View 2 Replies
View Related