AutoCAD Civil 3D :: COM API Section Links Give Erroneous Data?

Sep 27, 2013

Testing in C3D2012, using tutorial drawing "Sections-Grade-Label", selecting 2 sections depicting the existing ground and datum. Note that the datum in the drawing stops correctly where it intersects the ground:

However, when I gather the start/end points for the section links I get points that fall outside the limits of the datum section:

The second item appears to be the daylight point, but the first item is at the edge of the section view with an elevation that makes no sense. At the other side, item 17 is the daylight point and items 18-21 do not appear to be related to anything else in the sectionview, other than #21 which is again at the edge of the sectionview. What could these extra points/links be for? Intersetingly, the same section in C3D2014 returns 1 less point and all points through item 17 are identical, but those following all differ.

View 2 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Remove Excel Data Links From Reference Manager?

Jun 26, 2013

I am using Rel 2013 C3D

How do I remove excel data links from my Reference Manager (see attached image). What I have been doing is AutoCad erasing the graphics from my drawing but the link still remains in the xref manager window.

View 5 Replies View Related

AutoCAD Civil 3D :: Section Data Band Properties

Nov 5, 2008

I have an EG and FG data band for sections that works correctly. When i plot sections and it asks me specify surfaces 1 and 2, I choose my EG and FG surfaces appropriately. Then when the section displays the Section 1 and Section 2 are both set to the EG section of that specific sample line. If i change the section view properties manually it works but I'll have to do it individually for each section.

Also, is it necessary to create a FG surface from the corridor or can i get the data band to read from the corridor section itself?

View 8 Replies View Related

AutoCAD Civil 3D :: Cross Section Data Bands

Jan 2, 2009

I am creating a data band for Finished Ground. I have created a Top surface from my corridor and have sampled that as well as my original ground. I am trying to add data bands to an existing cross section view. When adding data bands for the cross section, I first go to the Section View Properties, add the data band, in this case, "FG Elevations", In the "Section1" column, I pick the Corridor surface that was sampled.

The data band does not display data. I know the data band works, because I picked the original ground as the "Section1" and it gave me the elevation.

I have noticed that under the "Sections" tab of the Section View Properties, and in the "Type" column, the original ground surface has a different symbol than the corridor surface. I have also noticed that if I have only the "Draw" boxes for the sampled corridor surfaces in the section view checked, nothing is drawn the section view. The corridor surfaces seem like they are not really there. Am I not able to retrieve data band data from a corridor surface?? If this is the case how do I go about making the corridor top surface something I can get data from?

View 4 Replies View Related

AutoCAD Civil 3D :: Surface Data On Section Views Disappeared

Apr 8, 2013

I created some about 20 cross sections for a creek we topo'd and then went to work making the topo itself look presentable. After I was all done with that I noticed my cross sections had lost the surface data and were now just an empty grid.

When I go to edit a cross section's properties in the elevation tab the "Automatic" choice has a minimum and maximum elevation of 0. When I use one of those existing sample lines to create a single cross section the same thing happens, it's not picking up data from the surface. However, when I made a new sample line along the existing alignment it picked up the elevations and created a cross section just fine.

Is there anything I can do besides recreating all the sample lines and cross sections? I'm looking for any other way because I have already labled and put in some extra work on the cross sections and I'm hoping to be able to just recreate what I already did and drop them so it will match the linework I already did.

View 2 Replies View Related

AutoCAD Civil 3D :: Adjustment Of Section View Data Bands 2013?

Jan 14, 2013

I have many section views of a road where I want to calculate ground volumes. I have a curb in a section view and I want that Civil showed me just an elevation at the top of the curb and at the top of the road cover. Is it possible to do that? And also distances: I want that Civil just show me a distance from the center of a road to a curb and from a curb to the edge of the road.

View 2 Replies View Related

AutoCAD Civil 3D :: Corridor Section Editor Data Overrides Not Displaying In Cross Sections?

Jan 9, 2014

I have added intermediate sample lines in my corridor.  These sections appear in the section editor and I can make changes to the data.  The changes show correctly in the section editor and section view, however, when I plot the cross sections some of these added stations do not show the overrides.  They are showing the original assembly group parameters.  How do I get all the cross sections to reflect the edited data from the section editor?

View 3 Replies View Related

AutoCad :: Data Links And Blocks

Jan 16, 2014

My company produces drawing sets that show the same information in multiple places. I.e. an attribute in drawing A is also shown in a different block in drawing B and a different block in drawing C and in a table. This creates problems in that as soon as one piece of information changes, you have to change it in 14 places... and it creates typos. A LOT of typos. So I'm trying to come up with a good solution as to how to link these pieces of information.

I know how to use data links in a table... but is there a way to link block attributes? Also, am I just barking up the wrong tree? Because in my head, you'd have to manually link all of these things for every new drawing, and they can be easily broken.

View 6 Replies View Related

AutoCad 2D :: How To Manipulate Data Links

Jan 31, 2013

How to manipulate data links? I want excel tables to come over and use their native excel formatting. I have a heck of a time getting them to look right (text size, font, justification, cell size, etc) and then when I update the link after making changes to the XLS, they get all cattywompus again.

I've never been real strong on text management in CAD; I'm always scaling text and doing poor drafting things like that. So I looked into Tablestyles and things a bit and thought I had it, but not so much.

View 5 Replies View Related

AutoCAD Map 3D :: How Many Data Links Can A Drawing Handle

Mar 5, 2012

How does the datalinks handle the links to the excel spreadsheet.  I am drawing parcels from legal descriptions and would like to link each parcel to a spreadsheet with all the parcels data via a ID number.  Then be able to click on that parcel and see the owner (the link). But my question is: do I have to give each link a new name to correspond with the parcel in order to see each parcel ownership? 

And how many datalinks can a drawing handle. 

View 7 Replies View Related

Photoshop :: Make Composite Image From Layer Data Instead From Merged Data Section?

Jun 1, 2013

I am working on parsing the psd file and saving the data as per doc of photoshop 6. I need to make an image from the layer data alone with different combinations of layers selected, visible etc... and not using the merged data section in the file.

View 1 Replies View Related

AutoCAD Civil 3D :: Pipe Section In Full Height In Section Views?

Feb 20, 2013

I have lots of section views with some surfaces and pipes. Unfortunately, in a number of section views pipes are not shown in full height because the section view level range is too little. What I am wondering is - is it possible to automatically adjust section level ranges so that they fully include pipe sections? Please see also the image in the attachment.

View 2 Replies View Related

AutoCAD Civil 3D :: Alignment Style - Section - Line Marker In Section

Mar 26, 2012

C3D 2012...but this feature has probably been in C3D for sometime

1-What is a 'Line Marker in Section' Section component of an Alignment Style?

2-How is it used (example )?

View 1 Replies View Related

AutoCAD Civil 3D :: Creating Section Sheets From Multiple Section Views

May 21, 2012

When i am creating section sheets from multiple section views ,section sheet  view port scale  changes.I did set it correctly in my template.

For example it changs from 1:150 to 1:150_1 

Then in section sheets scetions views are not displaying correctly.

When i change view port scale manually it shows correctly.But it should do to all sheets.

What should I do?

In model spacr multiple section views are showing correctly.

AutoCAD Civil 3D 2012 SP 2
Sri Lanka

View 8 Replies View Related

AutoCAD Civil 3D :: Adding Cross Section To Section View Group?

Jul 17, 2013

Is it possible to add additional cross sections (sample lines added after views were created) to an existing Section View Group?

C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit

View 9 Replies View Related

AutoCAD Civil 3D :: Section Editor Vs Section Views Labels?

Aug 12, 2013

In my section editor my labels show up correctly and in all the locations I want.  But then, in my cross section file, I look in my section views and they are completely different.  When I try to label more points under the Code Set Styles, they won't even show up on my section views. 

View 6 Replies View Related

AutoCAD Civil 3D :: Can't See Corridor Section In Section Views Only Existing

Mar 5, 2012

I think I just haven't done this in a while and can't find the right setting.

I have existing sections.
I have section views.
I created a corridor.

How do I add the corridor section to my existing cross-section in the section views?

I can view them in the corridor section editor.  But I should also be able to add the corridor section to my section views, right?

To plot them, do I NEED to do this through Sheets Sets?  I don't have experience with sheet sets yet.

I don't use Civil 3D often enough anymore.  Still learning much about the new interface and pulling a design together.

View 3 Replies View Related

AutoCAD Civil 3D :: Corridor Section Editor Not Displaying A Section

Mar 8, 2012

I've got a corridor where the section editor does not show a section that the corridor has created.  My frequency is set to 25' with high/low points along curves.  At station 22+75, in the model space the corridor shows a section being created (image #2).  However, I cannot edit or even see that section in the section editor (image #1).  The first screen shot shows the list of stations for the corridor in the editor while the second screenshot shows the model space at the problem station.  This is in the middle of a region, so there shouldn't be any issues with other assemblies or regions.

In the section editor, Sta 22+74.91 is listed, skips 22+75, then lists 23+00.  I am needing to manually adjust the cross slopes of my lanes.  If I view the surface there is a weird dip because at station 22+75 the default slope of my lane is -2%.  I cannot edit station 22+75, so I cannot adjust the cross slope of the lanes.

What is causing the section editor to not even recognize a section?  How can I edit the cross slope at station 22+75 if the editor doesn't even display that section?

Infrastructure Design Suite Premium 2014
Civil 3D 2014 x64
Windows 7 64-bit
6GB RAM

View 6 Replies View Related

AutoCAD Civil 3D :: Section / Section View Of A 3dpolyline Along The 3d Polyline

Oct 12, 2012

I am working in Civil3d and have a 3d polyline that i want to generate a 2d section line of i.e the path of the section plane is along the 3d line

View 1 Replies View Related

AutoCAD Civil 3D :: Unidentified Section In Section View

Nov 8, 2012

I am having an issue when producing a section view with my corridor.  I have a corridor and corridor surface, as well as an existing ground surface.  I create a sample line group and sample EG, Corridor Surface, and Material.  When I produce a section view I get 4 sections in the view: EG, Corridor Surface(with the corridor surface naming convention), and an additional section simply called "Corridor Surface". 

This last section is strange in that it seems to be using the correct assembly, but not targeting the correct features.  Also it has grips at all of the vertices which I havent seen before.

And the strangest part, when I click on properties for this section and go to section data, the columns for Description and Data Source are blank.

If there is no data source, then where is this section coming from, and why is it showing up when I did not specify that it be created.  This is a real mind boggler to me and makes no sense.  Screenshot attached.

View 5 Replies View Related

AutoCAD Civil 3D :: Section View Properties - Section Tab?

Oct 16, 2012

My future ground somehow disappeared out of one section view in my group. Under the section tabs I still have my existing ground and pipenetwork but the future ground isn't there. It remains in the other section views. How do I add it back?

View 1 Replies View Related

Photoshop :: Keep Getting Erroneous Restart Request?

Oct 15, 2012

I run CS4 on Windows 7.  Whenever I boot up, I get an error/prompt that says I have to restart the computer for updating to continue. 
 
I know this has been discussed in many different places here, and I have tried everything everything I can find in them.  Sometimes I get a fix, and then the next time updater runs, it's back. 
 
Why can't this well-discussed problem be fixed in an update sometime?  Or, perhaps this is my penance for still using CS4.

View 2 Replies View Related

AutoCAD Civil 3D :: Create Assembly That Give Volume Of New Shoulder Along Existing Road

Apr 10, 2013

I need to create an assembly that will give me the volume of a new shoulder along an existing road, as show in this picture.

I can easily make an alignment along my edge of pavement, and match the existing elevations, but I need to hold the cross slope constant AND the shoulder slope constant, and have the bottom of the shoulder slope to a target 2 feet off of my ROW.

View 1 Replies View Related

AutoCAD Civil 3D :: CorridorState Shapes And Links

Dec 9, 2013

I'm developing a custom SA in C#. At some point, I need to get a shape area and a link length from other SA (created with subassembly composer). This SAC subassembly is created before my custom SA in the assembly.

In the DrawImplement function the corrsidorState list of links and shapes is empty...

View 1 Replies View Related

AutoCAD Civil 3D :: Generic Links Colour

Jan 31, 2013

I'm building a simple subassembly from generic links and some of the links are blue and some magenta - Is there any significance to this colouring?

IDSP Premium 2014 (mainly Civil 3D 2014 UKIE SP1 & Infraworks with some limited 3ds Max Design)
Win 7 Pro x64, 256Gb SSD, 300Gb 15,000 rpm HDD
16Gb Ram Intel Xeon CPU E5-1607 0 @ 3.00GHz (4 CPUs), ~3.0GHz
NVIDIA Quadro 4000, Dual 27" Monitor, Dell T3600

View 1 Replies View Related

AutoCAD Civil 3D :: Multiple Direct Links

Aug 22, 2013

why am i not allowed to have multiple direct links for a node (junction/outfall)? i have a situation where i want to add the flows to two junctions, one for each side of the property, then add the two junctions to an outfall (overall site). i do not want to model the pipes, just want to add hydro graphs.

my each junction has two direct links coming from two other upstream junctions, and then this junction flows out by a direct link to the overall site outfall (the set of junctions from the other site does the same). i cannot run the model because of the error:

ERROR 134 : Node TOTAL-EAST has more than one DIRECT outlet link or DESIGN pump. 
ERROR 134 : Node TOTAL-WEST has more than one DIRECT outlet link or DESIGN pump.

View 2 Replies View Related

AutoCAD Civil 3D :: Subassembly Links Not Showing Up?

Mar 9, 2012

I created a simple sub-assembly for a windfarm project but when I bring it into civils none of the links or points show up!

View 3 Replies View Related

AutoCad :: How To Plot L And X Section Of Road From Excel Data

Jul 14, 2012

how do I plot L & X-section of Road from excel data that has chainage and RL at the centre,left and right of the chainage point?

View 1 Replies View Related

AutoCad :: Make Road Cross Section Using Xyz Data?

Sep 4, 2012

I am using AutoCad 2007. However, I do not know how to make a road cross section using xyz data.

View 6 Replies View Related

AutoCAD Civil 3D :: Inlet-01 Doesn't Have Two Outlet Links

May 8, 2013

On grade Inlet Inlet-01 does not have two outlet links. At least one stormwater sewer pipe and a bypass gutter link must be defined.How do I add another link?

View 1 Replies View Related

AutoCAD Civil 3D :: Bypass Links And Hydrodynamic Routing?

Sep 18, 2013

How are people modeling curb inlet bypass flow?  When I first got into using SSA, I looked on-line through some AU handouts and blogs etc.  I learned to model on-grade inlets using direct bypass links. I would create one that linked upstream and downstream inlets. It appears that hydrodynamic routing is the preferred option for modeling pipe networks with storage nodes, and the direct links don't work due to error 134.  It would seem that the logical fix for this is to model all gutter bypass as user defined open channel and create a channel section that matches the road and gutter section.  Is that correct? Also, how does the software view a direct link versus open channel?

View 5 Replies View Related