AutoCAD Architecture :: Scheduling Doors From Door Tag
Feb 20, 2011
Currently our door schedule populates when the doors are inserted into the drawing. I would like to know if I can set the schedule up so it populates when the door is tagged. Our doors are inserted into a base plan and that base plan is xrefed into various sheets.
The doors are tagged in one of these sheets and not the base plan. It takes too much time to stop and set up the schedule to schedule the doors across the xref for every project we do. I have read several articles but none of them explain how to schedule from the tag that I can see. I thought this was how the schedule was set up in a previous version.
View 3 Replies
ADVERTISEMENT
Jul 24, 2011
I am using groups for each type of apartment in the project i am doing, Some groups are mirrored, In my door schedule i added a parameter (instance) for my door orientation (Left or right orientation). The problem is when i note a door ina group as left and the same door in the mirrored apt needs to be right it keeps the same note for each door as it thinks the group in not mirrored.
View 3 Replies
View Related
May 29, 2013
I am trying to add the typical category of "glazing" to a door schedule, but when I add a door with glass into my project, I cannot make this information show up on my schedule. I need typical information such as "!/4" Temp" and "1" Insul" under the category of glazing. I added the "Door: Glass" heading in the schedule, but nothing appears when I add a glass door into the project. I was able to easily do this in AutoCAD Architecture.
View 5 Replies
View Related
Dec 16, 2008
How to group wall types together when scheduling a drawing?
I have multiple wall types within a drawing but scheduling produces multiple entries per type depending on length, only grouping them together when lengths are identical. All I need is a total length per wall type within the drawing.
View 5 Replies
View Related
Feb 28, 2012
I working on a deadline with little sleep, but I cannot believe it is this hard to get an overhead door to look right. All I want is a 1" thick frame, the same depth as the wall AND the door slab to be INSIDE the frame like a real overhead door.
The attached PDF shows the standard OH door on the left with the stupid door centered in the frame. The door on the right is one I created by inserting a cased opening in the wall, then manually drawing a rectangle and dashed line for the OH swing. All I am interested in is getting this right in plan at this point. Using Architecture 64 bit.
View 9 Replies
View Related
Feb 14, 2012
I have ACAD Arch 2012 and I am trying to associate my door tags with my door schedule and visa versa. I get as far as creating the Door Schedule with all the doors on it and quantified just the way you would want to see it; however, the "Mark" remains "A" for every door. I discovered that I can change the Mark on the extended properties of each door, but I believe there should be a better (and more linked) way to accomplish this. Since the program already recognizes how many doors there are of a specific style it should be able to put sequential "marks" to each door, for example "A", "B", "C", etc.
what's the difference between Door Tags - Project Based and regular Door Tags?
View 1 Replies
View Related
Apr 29, 2004
--Is there a way to do a door schedule by styles rather than individual door?
--To clarify: I want my door schedule to create a new door number only when one or more of the property sets, classifications, or door styles pertaining to a door are not defined by other doors in the schedule. This would facilitate giving the same door number to multiple doors that have matching schedule information, and cut down on my schedule size.
--how to do this. If I need to create custom tags, schedules, or formula properties.
View 9 Replies
View Related
Sep 26, 2012
Is there a door family out there that contains double opposing doors. These are very common in healthcare settings and I'm not finding a family to make this work.
View 3 Replies
View Related
Aug 11, 2011
On one of our drawings all of the doors (aparently except for one) detached from their host walls. The doors were still in their places, but un-anchored. We can go through and re-anchor them, but that's a lot of work, especially since they get shifted to the point on the wall you pick to re-anchor them.
1) Is there an easy way to re-anchor them to their original location?
2) What caused this (so that we can avoid this in the future)?
View 9 Replies
View Related
Jun 10, 2011
When I select the doors I want to use for my floor plan I can't see the picture of the door that I selected before and after I place it onto a wall, when you usually can. You can only see it on symmetric view, but not in a floor plan bird view, all you see is a gap in the wall (looks like the wall is split into two separate pieces). This only occurs for the doors, the rest of the design tools, I can see their pictures before and after, on the floor plan. I think maybe changed some settings, I'm not use. Maybe there is a way to set everything to deafult settings?
I'm using AutoCad Architecture 2011 (metric)
View 5 Replies
View Related
May 24, 2012
have trouble moving doors or windows within a wall?
I am trying to move a door so that the door is flush with a face of wall. The prompts in acad do not match the instructions.
For instance; select door, okay. then from anchor panel select 'reposition within wall', okay a red line appears and prompt to 'select position on the opening'. okay so i click the face or side of door jamb then select a reference point. (guide says select point to measure to) and on and on. Door never moves.
it should be; select door, select reposition in wall, select reference point (interior, exterior, midpoint), select the desired location. Done.
Instead it is select this that and the other , measure from here, select, click.click click.
View 3 Replies
View Related
Oct 2, 2012
I don't recall changing any features in AutoCAD 2013 that would take away my ability to type in the distance that I would like to place doors or windows along my walls, but now that it has been disabled and I don't have it.
View 2 Replies
View Related
Jun 20, 2011
When the spaces are auto created, is there a way they would include doors? I mean, doors are also floor area and they should be also scheduled/added to the space.
View 3 Replies
View Related
Jul 16, 2007
I am having a little trouble with some doors showing up on the level 1 door schedule that are actually on level 2. They are curtain wall doors.
View 6 Replies
View Related
Feb 8, 2012
I've just upgraded to ACA 2012. I can see how to insert a door in either an offset "or" centered position, but not both. In my previous version, the position could be set to "center / offset" which was an "and / or" option depending on the cursor location. Is this option available in ACA 2012?
View 2 Replies
View Related
Feb 14, 2012
how to adjust the display level on doors.
I have attached a PDF of my problem.
In the sketch is a simple room with 3 types of doors.
A Single door which displays properly
An overhead door which has a sq box attached to it and
A Double door which has all sorts of lines/boxes displayed on it
Ho do I get the doors to appear normal in plan view.
View 1 Replies
View Related
Feb 8, 2012
I am using ACA generic walls and doors for quick schematic room layouts.
I use the sheet set manager to make sheet with views.
All 2D linework is visible in the views, but the walls and doors (AEC objects) do not appear!
View 2 Replies
View Related
Dec 21, 2009
We have a house plan that has windows and doors of different types anchored to their walls. It seems that whenever someone is working in a file from the network that has the plan xrefed into it and the plan is opened to be modified by another user the windows and doors randomly detach from the walls. We're getting tired of going back in and reanchoring them.
(We're using Autocad Architecture 2009 on Vista)
View 2 Replies
View Related
Mar 6, 2013
This just started happening with 2013. The doors are no longer staying put when a wall is extended or trimmed. Somehow they now move relative to exthe endpoint of the wall. Happens with windows and openings as well.
Is there a new default setting I'm not aware of?
View 1 Replies
View Related
Jan 9, 2012
I'm trying to send a set of drawings for my consultant. They will be using it as a background for their mechanical and electrical drawings and they only need the 2d information. They want to be able to explode them and remove any items they don't need before switching all the layer colours to grey.
When they get the drawings and explode them the doors and walls explode onto the correct layer but the colour of those object and lines are now set to the actual color of the layer rather than colour "bylayer". The line actually take on the colour of the layer in the properties dialogue box. Therefore when they change the colour of the layer to grey the doors remain 'red'.
I would like the doors/walls to stay on their respective layers...AND their colour to be BYLAYER when exploded.
View 7 Replies
View Related
Mar 6, 2012
Okay so to start with I have a building with 2 staircores. Everything is drawn in 3d and I have drawn the 2 staircores as elements and subsequently Xrefed these elements into the relevant constructs and subsequently a 3D model view.
When I view the elements as a live drawing (ie. when I open the individual elements) the drawing views okay in plan and in 3D wireframe, hidden mode etc... no problem so far!
When the drawing is Xrefed into a construct and subsequently a 3D model all of the windows and doors disappear... but in 3d only - ie. viewed in plan mode they are fine. I have checked the display configurations in the constructs and views and they are all set to display these objects in the medium detail and high detail for the model and plan modes.
In 3d wireframe mode the windows and doors can be seen within the wall but the opening which they should create is non-existent!This occurs in teh construct and view drawings.
Here's the catch.... I have a 'West Staircore' and and 'East Staircore'. Both are drawn as individual elements. The West staircore is giving trouble, but the East is perfect. They were both set up using the same DWT file which means that the default display configuration settings should be identical.This is backed up by the fact that they view correctly in the live element drawings.
When they are both Xrefed into the same construct, one is fine and the other will not display in the 3D model!
View 3 Replies
View Related
Feb 1, 2013
I am opening a file from 2004 and I am using AutoCAD Arch 2012. When I open the file everything is there, but the doors do not cut through the walls. The doors are still there but are not "anchored". Is there a way to fix this easily? I also lost everything out of my door schedule. I know I will get my schedule back when the doors get anchored back to the wall.
View 1 Replies
View Related
Feb 1, 2012
I have a model with 5 reference drawings. Everything has been going fine. I am making modifications in 2d wireframe view Then I change to realistic view and conceptual view and see that half of my windows have disappeared and some doors. I open up the first floor plan and see that most of my windows, doors, and openings are not cutting the walls. It just happened and now I cannot get them to anchor in the wall.I did purge, -purge R, audit, recover and closed and reopened the program. No Change! What could have caused all of these objects to lose their anchor?
View 1 Replies
View Related
Mar 5, 2012
ACA 2011:
I created a Dr & Wdw Assembly w/ 3 French doors w/ 3 Transoms above. It looks great. However, the door panels in Plan view are closed. Yet the in the properties dialog box it says they're each 90 degrees open. I can change the number, but the door remains closed. What needs to be tweaked?
View 2 Replies
View Related
Jul 4, 2012
I made a door tag, tagged all 128 doors and during a check set noticed that the text in the tag is the wrong font. I opened the tag and changed the font, saved and regenerated the drawing. The font in the current door tags did not change. To be sure I changed the correct tag I added a new tag and the font is correct. Why do the current tags not update? Do I need to do something? I do not want to go back and redo all 128 door tags.
View 2 Replies
View Related
May 26, 2011
In the attached image, the left is my 1st floor RCP, which looks the way I want. The right is my 2nd floor RCP, in which I cannot get the door jambs (orange lines) to turn off. Cut Planes are set identically in the two dwgs. I thought the Display Configuration settings were identical in the 2 dwgs, but clearly they're not.
View 4 Replies
View Related
Jul 1, 2012
I am trying to number my doors, and the door tag (AEC6_Door_Tag), won't let me create door numbers with 3 digits. I have never had this problem before. It keeps creating tags with 2 digits.
View 6 Replies
View Related
Oct 18, 2012
I have an assebly with the door going down to grade level and the flanking windows 30 inches up. I used a profile to create the assebly shape. In plan you cannot see the brick below though you can see it between the assemblies.
View 5 Replies
View Related
Aug 19, 2013
We do residential design, our doors and windows need to read 3068 and 3050 etc. I have tried everything but I cannot simply get it to work.....This is what I have done:
*Insterted a door tag from AA2014
*I exploded the tag twice and deleted the circle around the text
*Renamed the nested block and edited to include "OORSIZE"
*Went to style manager/the plan/Doc Objects/Door styles/definition/ changed it to read "STD Door Description"...
see attached file.
View 9 Replies
View Related
Feb 12, 2013
i have created a door schedule and it seems to be missing the most important part, the sizes! When I go into Style Manager and click on the door shcedule and try to add columns size does NOT come up as a choice. I have added size to the property sets of the doors. I have tried everything I can remember from older versions of Autocad and it just won't put in this bit of information.
View 6 Replies
View Related
Sep 9, 2011
Is there a way to disable the ability to Flip the swing orientation of a door so that a RH inserted door cannot be changed to a LH?
View 2 Replies
View Related