by default. I forget what but there's some routine to make this family cut properly in a plan view. Why they made viewing the top of the family the default position I DON"T KNOW but what do you expect from programmers?
Is it possible to add a color region to a family in plan view? I need to add a color region to the plan view of a single flush door family for training purposes (several co-workers see color filled areas better than black and white single lines with the projector we have). I would like to add a color region to the door and frame in plan view of the door family.
I modified a Window Family file by adding a Window inset parameter. When I inserted the window into a wall, otherwise the window worked fine, but when I changed the window's Window Inset value, the frame depth changed instead of the frame's location. The frame was originally made by Sweep tool, but now when I made it by Extrusion tool, the window works fine. Anyway, for future purposes, I would like to know how to be able to use the Window Inset parameter with a frame made by Sweep tool. How do I lock the depth of the frame sweep?
We are developing a multistory housing project that will have 5 unique unit plans. What I would like to know is the best approach to implimenting the unit plans in revit?
In autocad, we would create an xref of the unit, then xref as needed on base plans. Thus the ability to place multiple xrefs of the unit on various levels while maintatining the ability to make one change to the original unit plan and have it update thru out the project....How would we do this in Revit?
I am working in a project where I need to represent the reflecting ceiling edges in the plan view. I put the first floor plan as underlay, and selected the RCP projection but I don't see the dropped ceiling lines to select them with the linework command. I have done every thing possible with the view range but I don't see the lines.
I have several window types in my project. Let's say that the window is 3'-0" wide by 4'-8" high - Mark #1. I want to group three of these windows and schedule the group as Mark #2 - not three separate #1 windows. How do I set up the three windows together to become a single window schedulable for the entire opening of the three windows grouped together so that the opening would read 9'-0" wide?
We have our first project in Revit that we are having to split among multiple sheets because of the size of the building, so I have made 3 dependent views from the main overall view, named them, cropped them and placed each part (A,B, and C) on separate sheets. Now that I am trying to do enlarged toilet plan views, I want to tag the plans with the plan callouts on the 1/8” sheets that are the dependent views, but all the view tags are referencing dependent view A since it is the first dependent view in the list. If I change sheet A to be named Sheet X for instance, all the view tags now reference sheet B since that becomes the first dependent view alphabetically. I want them to reference the sheet they appear in, but I can’t seem to figure out how to do that, even though they are in different dependent views completely and within the crop region, they all default to the first dependent view in alphabetical order.
I would like to cut a void into the wall of a host window family. When I place a void in the family, it does not cut thought the wall.
I tried making the void on a plane perpendicular and parallel to the wall plane. I dont know if this has anything to do with how voids work. But its not working. I also dont have an 'opening' element in the window family.
I am semi-new to Revit and am trying to make a go of it. I am trying to make a window, that looks like my AutoCAD window. So I open the Window Family.rft to start creating. I can adjust my wall thickness to match my brick wall, I can set the frame to the void that is already there.....my problem comes when I want to put on the brick mould. This overhangs the window frame and thus is outside the pre-ordained void. When I try to make a void extrusion to cut back the outside face of the wall and allow the brick mould to show, it will not work - only the originally supplied void (that comes with the template) works.
Revit will not allow me to "Cut Geometry" saying "A Family cannot have an opening and cut in the same host". If I set the brick mould inside the supplied opening, then the inside face will have a gap between the drywall and the window frame.
I am using Revit Architecture 2013 and am trying to create a window family that has different grid options built into the family. I have included a copy of one of my window families I am working on and an image for an examples of what happens when I load all my windows into a project and place them. Some of the grid families do not automatically adjust to the size it should be. But if I click on the window (lets say it as no grids) and then select the no grid parameter again then it will adjust. How I can get these windows to adjust automatically so I don't need to do an extra step to make them look right!?
I am using AutoCAD Architecture 2011. I've inserted 3 windows in an exterior wall. They all can be seen in Plan (top) view. I've gone back and changed the height of the windows. Now when I look in Plan (top) view, the windows I've changed the dimensions on are no longer visible.how to make these windows visible again in plan (top) view?
Note: These re-sized windows can be seen in any other perspective except Plan (top) view.
I have linked a file that is far away from the window (cropped or not) and I am having issues with trying to locate it on my view how can I relocate it to where my work is?
I am working on my first real Revit project. i need to modify a windows family and in particular i want to change the axis of insertion of the window in the wall. I mean... my window should be placed on the outer edge of my wall. i try to unlock the dimensions that define its position and then i lock the dimension in the new position; the window seems to be ok but only in the RFA file. When i imported it in my project file, the windows moves in the wrong way in my real wall.
I'm trying to create a custom view title family for the office (see attached). We'd like to have a label for Drawing Type (ie. "Building Plan" in the attached image) in the view title which would appear in the properties tab under identity data, next to the standard Title on Sheet, View Name, etc.
In the project, I am able to create a project parameter which appears as desired in the properties tab, but am unable to add the parameter inside the family when creating it. It seems impossible to add this parameter to the standard view title family template (alongside Detail Number, Sheet Number, etc.).
I tried it using a Generic Annotation family, but in the project, Revit does not recognize that family as a view category family and therefore you cannot choose this family when setting your view type.
I've been downloading some families from seek. Each time I download, I open the family and then load it into the current project. Well, during the load into current project, the view switches from Level 1 New (the active view before the family load) to Level 1 Existing, the first view in the project. Is this intentional or a bug?
I was following a tutorial when he created a structural plan where he'd place his footings. when i tried it on my Revit Architecture 2014, i found out that i didn't have that feature. is there any way i can turn it on?
i'm not sure if he's using revit architecture because he just refers to it as Revit 2014. i made a floor plan below the 0 mark but things will be tidier if i could make structural plan views.
If i draw a beam in plan view en define the height, the beam disepare. Is there a posibility that the beam is in place and you can see a dash dot line and two dashed lines in plan view?
I'm currently looking into switching from Vectorworks to Revit due to a job application I'm being offered. What I really want to know is if the following floor plan is possible to make in Revit. I just want floor plans to be with color to better show the different things on it and make them more clear.
I also want to know if it is possible to show symbols in a plan view other than just a rendered hidden line view of the 3D part of it, so I can have a simplified version for the plan view and a detailed object for the 3D. Like you have a 2D-plan component for the plan views and e 3D component for all other views.
I am already using autocad and Covadis (because I'm road-design, etc. ...-); I'm new building and I use Revit Architecture 2011
Already I do not understand why my isolated foundations are not visible in plan view when the footings are beautiful and well visible in the plan view,...
I've got some troubles creating a proper ceiling plan. What goes wrong (imo) is that my wall sweep is shown on my ceiling plan while it shouldn't.First image shows the ceiling plan. (on image 3 you will see the wall sweep I mentioned in red).
This image shows the view range used.This images shows the section (right), 3d (top left) and ceiling plan (bottom left) highlighted the wall sweep.Why / how do I prevent this wall sweep from showing up?
Explain the logic behind the differences between RVT Categories and how they display in Plan View?
Example:
I made a custom component (Family) that was set as the 'Generic Model'
Category.
When placed, its elevation was set above the Cut Plane but below the Top of the Primary View Range for the Plan View. The Object displayed in its entirety. I then decided that this component was really better categorized as
'Specialty Equipment'. So, I re-assigned it in the Family Editor, and re-loaded it into my Project. As I did this, the object disappeared from Plan View. I then switched to a 3D View to verify it was still present in the model - and it was.
So why does Generic Model Display, and not Specialty Equipment, I ask? I've discovered that if I lower the Elevation of the Specialty Equipment to exist at or below the Cut Plane, but above the Bottom of the Primary View Range; it will display in Plan View. I've also tested and discovered that adding Symbolic Lines to the Plan View of the Specialty Equipment in the Family Editor and re-loading into the Project will not overcome this issue of elevation - if the object is above the Cut Plane the Symbolic lines will not display either.
I note that Specialty Equipment does not have a "Cut" setting for Lineweights in Object Styles, and Generic Model does. Is this the indicator for this display behavior that I'm experiencing? And if so, why is 'Specialty Equipment' regulated to this type of Category? Why not have a 'Cut' setting for it?
Quite a fair bit of an Architectural model gets lumped into this Category:
lockers, toilet accessories, kitchen equipment, medical equipment, etc.
I accidently deleted a section marker from a plan view. The section still exists and in shown in other plan views. I feel stupid for asking, but how can I get the section marker to reappear on the original plan view?
bring back my site plan view!, and the ability to use shadow and realistic material!because when did another site view i am unable to use shadow and realistic view!