Revit :: Correcting Error In A Family Being Created
Sep 21, 2011
I'm trying to create a new family - a window with sill and lintel. In the attached file, I'm fine until I add the reference planes to create the fixed window frame. Prior to that point, all geometry perofrm as intended when I change the width or height of the window. Once the frame reference planes are added, the height change draws an error message. I've tried individually eliminating the possible causes with no success. What I'm doing incorrectly and specifically the steps necessary to fix it?
I have placed showers within various apartments. These apartments are groups. I have made a change to the family, (realigned a reference plane to be equal between two points). Now I reload the family into the project and no matter what I try, I cannot load it into the project without getting the ungroup error.
Prior to the warning, it states i need to delete a number of dimension references. Which I allow, then the group error appears telling me I still have constraint problems.
I thought it would be fine to dimension to families in groups, but it appears their is the potential for problems.
I'm trying to align a nested family to a reference line in my host family so that it rotates around a certain point.
I've created the reference line in my host family, locked the end point to two reference planes and then gave an angular parameter to the angle between the ref. line and the ref. plane.
I then inserted the nested family and aligned it to the ref. line. The problem is that when I flex the angle, i get a "Constraints not satisfied" error..
What could be wrong?
I'm using a generic face based family for both host and nested families...
I am trying to place a receptacle on a wall and I keep getting this message "None of the created elements are visible in Floor Plan: Basement Demo. Plan - Electrical View. You may want to check the active view, its Parameters, and Visibility settings, as well as any Plan Regions and their settings." I have everything turned on in my visibility graphics.
I created a new library to publish some profiles we use in our company. But some profiles didn't work exactly as they were supposed to do. So i tried to delete some of the families i created. But the Inventor doesn't allow me to do so. The button to delete the family just is in gray, and i can't use it. How can i delete the families i created?
In Revit 2013 I attempt to load an item from the Family but I find that the “Load Family” dialog box does not appear. how to get it to cooperate? Even starting a new project the load family dialog box does not appear. I have done: 1) system restore, 2 ) repaired install, 3 ) re-installed, 4) uninstalled and reinstalled from scratch but still the problems persists on this machine. all other office PC’s with Revit 2013 behave.
I've attached a simple RVT file with a family inserted and the front view active. I need to rotate the family 90 degrees but Revit reports the following error:
"Can't draw because Work Plane is at a very sharp angle in this view. Go to another view or redefine the Work Plane."
I have several window types in my project. Let's say that the window is 3'-0" wide by 4'-8" high - Mark #1. I want to group three of these windows and schedule the group as Mark #2 - not three separate #1 windows. How do I set up the three windows together to become a single window schedulable for the entire opening of the three windows grouped together so that the opening would read 9'-0" wide?
I downloaded a grab bar family that I thought looked very good. But then I tried to place it on the toilet stall portion (I also downloaded stall partition families). When I tried to place the grab bar, it wouldn't place -- I believe because the grab bar is WALL BASED.
So now the question is how do I go about placing a grab bar (or anything else) that is not wall based so that I can use it with the stall portion? I had tried to use face based but couldn't get that too work.
Recently, My revit does not load families. The process I use is the following:
In the Build area of the home ribbon, I select the Component button. I going to the Place component ribbon. When I select Load Family form the Mode portion of the ribbon, the properties box pops up. It is locked at this point and I cannot do anything but hit escape. The program functions just fine in all other aspects. I have used a vanilla project to see if the project I am working on is corrupted and I get the same results.
I am trying to create a custom planter based off some line work that I did in my project. It has a curve. basically what I have done is created the line work on plan but now I want to use that curved line to create my family. which I am thinking I can create a profile and then sweep it on those lines. The problem is I can get the line work to the family.
I'm trying to edit the keynote family with no luck. We are updating our standards and getting into using the keynote system in revit. I have added the correct keynote to most of our standard materials and its working great. I then opened the keynote family and changed the justification of the text to justify the way we do notes. I also changed the line style of the leader lines so it matches our other notes.
All went well. I get stuck when I try to change the gap between the leader tail and the text. I can't find anywhere to actually edit the line/arrow in the family that would let me change how that works. If you see my attached image the one on the top is our standard note and the other two are the keynote family.
I'm trying to create a frame and panel kitchen cabinet door family. It flexes correctly horizontally, but I can't get it to flex vertically. What do I need to correct?
This includes door opening/cased and opening-elliptical art. When I put them into my drawing they show up in the preview but do not insert into my drawing.
I know I must just be missing this somewhere, but I would like to shut off the geometry inside a family that's associated with a specific parameter. This is while I'm editing the family.
Specifically, the family I'm creating is for an appliance that has the option of an arched, or rectangular opening. Once I associate the geometry for the arched opening with a parameter, I'd like to shut that off, so that I can create the rectangular opening. Similar to how the family behaves once it's brought into a project.
Right now, I'm just kind of using the temporary hide functionality to shut them off, but if I turn them on, then have to go back to make edits, I have to select the individual geometry all over again to hide it. I've also noticed that some geometry, even when hidden, can still be selected.
As Revit insert a door it cuts the wall starting at the flooring level upward door height but in real building the door openning starts from the top concrete
Can I tell revit to start cutting the wall bellow flooring (leaving the door wing to start from flooring) or how can i add this feature to door family...i would like to control the height of the cut below flooring (e.g be a parametric).
The line color of my family is not showing up. It is just a symbol and it should be red, but it shows up black. I went to the overides in the project and nothing was overridden, so I went ahead and changed the imported families override to red just to see if it would change and it still didn't change. How do I fix this? When I open the family, the lines are red, just not in the project.
I created one panel family. On plan view, I added two parameter for just width and lenght (Picture 1), but at the same time, I cannot added parameter for adjust the angle in the elevation plan(Picture 2) .
I'm having trouble editing a family I've made. It's a profiled rim for a crate that needs room for a latch. So I need to create a small spacing in the rim so that the latch can fit. I've tried to cut geometry, and edit the family (rim) itself, but I need to edit it in an elevation view and not floor plan.
I am creating a fireplace family in Revit Architecture 2012 with wall host (Speciality equipment with Wall host). I selected the template created the family, but in mean time i can't understand the wall is having delete option.(i.e it is released from host). I am surprised to see that in the family type, the wall host is missing.
I want to Create a Wall Nitch that will be in a tiled shower we are doing. Best way to create a family that cuts into a wall? I don't want to Create an opening, because I don't want it going all the way through the wall.
Is there a Family Category that allows me to create an Extrusion that will then work with the “Attach Top/Base” tool?
For example, instead of using a structural column, I would instead like to use a Model In-Place Extrusion, then be able to attach these columns to my roof.
I’m noticing you don’t get the option to “Attach Top/Base” when you use a Model In-Place Extrusion.