AutoCAD Inventor :: Delete User Parameter
Apr 22, 2013
Most of the time, I delete an user parameter without problem. But, in a part, I got an error for two of them and I don't understand why. I create a new parameter and redirect all dependencies from the old one to the new. (oldParam.Dependencies.Count = 0).
But when I try to delete it, I've got an error. Also, when I try to delete it by the interface, I don't see the Delete option.
View 8 Replies
ADVERTISEMENT
Dec 23, 2011
I have user parameters that are no longer needed and are not being used anywhere. They each takes 4-5 seconds to delete, prior to 2012 this would happen instantly.
IV2014 SP1 64bit
Dell Precision T7500, Geforce GTX 480, DirectX11 306.97
SpaceExplorer 4.04, 3DxWare 3.12.2
Twin Intel Xeon E5506 2.13GHz, 12GB RAM, Win7 Pro SP1 64bit
View 6 Replies
View Related
Aug 24, 2012
Looking for sample VBA code to get all referenced documents from an assembly and add a boolean user parameter to each (parts and sub assemblies). I have been trying to modify peices of code I have found on this forum and Mod the Machine, but have had no luck so far.
There may also be standard content center parts in the assembly as well that I would like to somehow identify so I can skip over them.
View 1 Replies
View Related
Jun 10, 2011
Parameters with a text value, How do I add userParameter? In iLogic
Examples. DoubleValue)
Sub Main()
Dim oCompDef As PartComponentDefinition
oComDef = ThisApplication.ActiveDocument.ComponentDefinition
Dim oParams As Parameters
oParams = oComDef.Parameters
Dim uParams As UserParameters
uParams = oParams.UserParameters
strVal= uParams.AddByExpression!("strVal", 0.15, "mm")
iLogicVb.UpdateWhenDone = True
End Sub
View 6 Replies
View Related
Dec 1, 2013
I need to use the dimension created by an action-parameter as a variable in a user defined function but AutoCAD will not allow me (see attached).
How may I access the action-parameter's dimension ?
View 1 Replies
View Related
Dec 28, 2013
Is it possible to update an existing User Parameter. While I can only delete-create a new. In this case the connection is lost with BOMQuantity.
View 5 Replies
View Related
Aug 6, 2013
I'm having problems with the parameter menu. When I don't have a user parameter linked to a dimension in the model the parameter disappears out of the parameter menu.
View 2 Replies
View Related
Apr 1, 2003
I have a part file ("part1.ipt") that has a user parameter called "Height". When I open this file as a part document, I can modify the "Height" parameter to change the height of the part. This functionality works great:
Set oPartDoc = oApp.Documents.Open(sPartFileName, True)
Set oParameters = oPartDoc.ComponentDefinition.Parameters
'change part height to 30 cm
oParameters.Item("Height").Expression = 30
Now, I am wanting to add this part to an ASSEMBLY document, then change the parameter to 30, but have been unable to do it.
I have this so far:
Dim oAsmCompDef As AssemblyComponentDefinition
Set oAsmCompDef = oApp.ActiveDocument.ComponentDefinition
Dim oOcc As ComponentOccurrence
Set oOcc = oAsmCompDef.Occurrences.Add(sPartFileName, oMatrix)
After I add all the parts, I highlight a part in the assembly pane, I click on FxParameters but I don't see the User Parameters for the part. Are the User Parameters not available when a part is placed into an assembly?
This assembly will have multiple parts added from the same file name, but the "Height" parameter needs to be modified for each occurrence.
View 5 Replies
View Related
May 2, 2013
Is there a way to export a text user parameter?
View 8 Replies
View Related
Feb 7, 2012
it is possible to use a user defined parameter to drive a action parameter.
I have several polar and linear stretch actions i would like to drive from one parameter.
View 3 Replies
View Related
Aug 17, 2011
I am trying to make an iPart of a fitting where I can change the "Body type" and it will change all the parameters associated with that body type through iLogic. Really I am just playing around in iLogic to see if this is something worth learning. Back to the point, I would like to change a multi-value user text parameter through the iPart table but I cannot find the paramter in the parameters tab.
Since it is a user parameter I thought it would be in the "Other" folder but it isn't. I do however have the other multi-value user number parameter in that folder, which makes me think that maybe I can't use the paramter in the iParts table?
INV 2012 SP1
Windows 7 64 Bit
ATI FirePro V5800
14.0 GB RAM
View 9 Replies
View Related
Aug 26, 2010
I created a sketch that I would like to use in an iFeature. The sketch dimensions are controlled with an ilogic rule referencing a multi value text user parameter, eg the text parameter pull down menu controls the size of the part.
Is there an easy way to get this parameter into an ifeature or derived part?
View 4 Replies
View Related
Oct 29, 2012
Macro for writing the sheetmetal Extents width and length to the custom properties. I need to get these values into the part parameters so that they can be used in the BOM.
I can get this to work if I manually create the "SM_Length" user parameter, but how do I make the iLogic CREATE the parameters if they do not already exist? I think it would be something added below the "Catch..." just cant seem to figure out what it needs to be.
'look for custom iproperty and try to set it
Try
iProperties.Value("Custom", sExtLength)=Round(SheetMetal.FlatExtentsLength, iRoundValue)
Parameter("SM_Length")=Round(SheetMetal.FlatExtentsLength,4)
Catch
' assume error means not found and create it
customPropertySet.Add(Round(SheetMetal.FlatExtentsLength,iRoundValue), sExtLength)
EndTry
View 9 Replies
View Related
Jul 29, 2011
I want to use iLogic to create User Parameters with Multi-Value lists filled with info from an excel spreadsheet. What is the code to create a new User Parameter?
i7-2720QM Dell Precision M6600, Win 7 Pro 64-bit, 8GB RAM
Autodesk Product Design Suite Ultimate 2013
Autodesk Vault Professional 2013
View 4 Replies
View Related
May 15, 2012
We are having issues with text height and variations depending on how the text is added.
I am currently adding etching to sheet metal parts by using the user parameters (which are driven by 3rd party source, excel file) and using a cut extrusion -1mm.
We have developed a marco which detects the shape of each letter and adds etching to our sheet metal program manually. We do this to get rid of the double lines when you cut text into a part. Our process is design in Inventor, unfold then convert to DXF 2004, where we import to our SM programming package (Radan).
I have noticed that when using 10mm simplex if the text is driven by parameters and 10 point text is selected the charecter height is 9.9928mm, however if the text is added manually it measures 10mm exactly. Why is this happening? It is probably of no concern to most, but we would need to add extra charecters to our macro to account for the descrepency, and in turn would take the macro longer to run.
When the text is added by user parameters, you can briefly see the 10mm text height flash to 9.99mm when finishing the edit sketch. Changing this to 10mm again has no effect.
what is causing this, or have any alternative ways of adding 10mm simplex single line etching to a dxf from an Inventor 2012 SM part?
View 5 Replies
View Related
Aug 23, 2012
I have a users who cannot change parameter values for iLogic unless user is a local admin on the workstation. This machine has just been upgrade to Inventor 2013.
View 1 Replies
View Related
Jul 4, 2012
I have created a large complex assembly that is parametrically driven by a skeletal sketch ipt by means of an embedded excel spreadsheet.
I am cleaning up the models by deleting obsolete user parameters. But there is one that will just not give me the option to delete it.
I have interrogated the model inside and out but can not find anywhere that this parameter is still being used.
I go into the Parameter Dialogue Box (ƒx) and hover the cursor over the parameter and there is nothing that apears that indicates theis parameter is used anywhere in the model.
Is there an iLogic routine or some other method that will allow me to run a check or a search through the model that will point me to where the parameter might still be lingering.
I have attached a JPG if it will make things clearer.
RHRT_1 is the Parameter I am trying to get rid of.
BTW. The Models and Assemblies I create are guarded by Proprietry Laws so I am unable to send a copy to anyone.
Inventor 2012 Professional
View 1 Replies
View Related
Nov 1, 2012
I've created a main assembly containing several ipart components. With the following rule I can read the model parameters, but not the user parameters of the iparts:
A = Parameter("Part1:1", "d0")
If I create a component, insert it in the main assembly and make it an ipart afterwards, the user parameters can be read out with ilogic. But if I insert the same ipart again, the user parameters can not be read out anymore. Model parameters are no problem.
View 1 Replies
View Related
Mar 21, 2013
Where do I find the "Allow custom values" option for a multi list parameter expression?
View 2 Replies
View Related
Jan 3, 2014
IV2012 API with VB:
How can i add an item to a Multi-Value-List of an existing User Parameter in Inventor2012 (Accessing API with Visual Basic) ?
My idea is for example:
uParams.Item(i).ExpressionList.AddItem(As String)
The problem is, that such a function "AddItem" doesn't exist.
View 4 Replies
View Related
Oct 13, 2013
I am setting up a family of parts that consist of a round disc with a fixed OD and a circular pattern of notches cut into the OD. The notches must go to a certain depth from the center, so those parameters are set. My problem is that I need to control the amount of material left between the notches, along the OD, after the pattern is done. Given the fixed parameters of the major OD, minor OD (3.5" in this case) and number of notches, the only way to control the amount of material between notches is to change the angle. When I set up the sketch to do the notches, I can only get a fully constrained sketch if I assign a specific angle to the notch. I need to be able to set it up so that the angle of the notch varies so the end result is a specifc amount of material left after the circular patter is completed.
In the attached PDF, I show what I have done so far. In this case the OD of the part is 4" and the diameter of the notch at it's closest to the center is 3.5". So basically, I end up with a driven parameter of 0.443. If I assign this value the parameter of d14, I need to make it equal to a ratio of another parameter (let's call it d15) so that d14 = d15*2.. This can only be accomplished by changing the angle.
In my family, the major OD and minor OD remain the same, but the angle must change to retain a specific amount of material between the notches when the number of notches is increased or decreased.
Is there an iLogic rule I can write to control this?
View 6 Replies
View Related
Jan 9, 2013
Any way to modify a user form parameter's read only status using a rule?
I have a parameter that I want people to be able to edit when another parameter is set to true and to be locked if it's set to false. The only thing that comes to mind is have a rule that will just switch the value back automatically if the user changes it but it would be good if i could control the read only status.
View 3 Replies
View Related
Sep 27, 2012
In 2009 Inventor iLogic, we have a button to delete all parameters and rules. But now, in 2013 Inventor iLogic, I only find a button to delete all rules. Where is the button to delete all parameters?
View 9 Replies
View Related
Feb 13, 2012
We have some dnyamic block share set of parameters, if we change a parameter's value, all block that reference this parameter should be change.we can do it by program.
but create user parameters for a dynamic block must be by hand, can we create a user parameter by code? another way is user global parameter. does AutoCAD Parametric function's user value can be share with dynamic block?
View 8 Replies
View Related
Sep 25, 2012
I would like to add a new (user) parameter to a dynamic block within my code. I have noticed that this is possible manually. But couldn't find how to do this in .Net. When this parameter has been created it would be necessary to fill in a value. So the parameter can either be a general parameter, that can be adjusted later or a (user/dynamic) parameter specific for the block.
View 1 Replies
View Related
Apr 9, 2012
I'm trying to connect the value given by a calculated User parameter to a text. I've been looking for information everywhere, none found. Is it possible to show that value in a multiline text?
View 1 Replies
View Related
Oct 2, 2012
I need to convert a model parameter to a reference parameter thru the API.
I saw this item discussed in the group before, but I cant find the thread.
View 4 Replies
View Related
Dec 13, 2013
I added two output parameters in my custom SA. I no longer want them in there. But I can't find a way to delete them.
View 2 Replies
View Related
May 7, 2013
After getting Vault installed on our server and successfully setting up users and connections, I used the Library Transfer Guide to move our Content Center (including custom) to the Vault. I then changed the Inventor Application Options -> Content Center -> Access Options to Autodesk Vault Server.
This seems to have worked, as I can Place from Content Center when in an assembly, and it is pulling standard content as well as our custom files properly from the vault. However, in the instructions that I used for the installlation, it was suggested to stick with a standard folder structure within the Vault, namely two Library Folders named 'Content Center Files' and 'Libraries' and also a regular folder named 'Designs'.
I created those folders prior to transferring the library, as I thought they would be populated with the standard/custom content. This was not the case and I am curious when these folders come into play? *they are empty*
Also, today I will be attempting to 'Check In' a project to the Vault that I recently completed; does this usually maintain structural relationships between files?
Would you recommend using a single project structure in vault for two people? It seems, since we won't be working on the same project at the same time, having a single project would not be relavant to our situation..
Inventor 2011 / Windows 7 Pro SP1 64bit
Dell Precision T3600
Intel Xeon E5-1607 @ 3.00GHz
AMD FirePro V4900
20 GB Ram
View 7 Replies
View Related
Dec 19, 2011
I got a deadline for my project, but I got a big problem:
"I cannot set the "parameter" for the End Value in Parameter Animate dialog"
For easy understand, let's see a example:
1. I got a part which has two parameters named: "A" and "MaxA"
2. I animate Favorited parameter A.
3. The End Value is MaxA_ (Everything is ok)
4. I finish Studio environment, then I change parameter MaxA_ from 200 mm to 400 mm
5. I turn back to Studio environment, the End Value now is "200 mm" (I want this will be MaxA_, so I can animate the flexible parameter).
show me how to keep the end value will be "MaxA_" after I change parameter?
View 3 Replies
View Related
Mar 19, 2013
I have a problem to run Map 2013 today.
"System.IO.FileLoadException: Can't load procedure from 'MapPublishImp.dll'.File name: 'MapPublishImp.dll' in Autodesk. Gis.Map. TextEdit. UI.Map PublishHelper.Finalize()"
Fatal error and Map is closed..What I have done:
- Try to repair and reinstall, nothing
- Uninstall Map 2013, delete all program's and user's folders and clean Windows Registry, clean install of Map 2013, NOTHING (???)
View 8 Replies
View Related