AutoCAD Inventor :: Create User Parameter Values With ILogic

Oct 29, 2012

Macro for writing the sheetmetal Extents width and length to the custom properties.  I need to get these values into the part parameters so that they can be used in the BOM.

I can get this to work if I manually create the "SM_Length" user parameter, but how do I make the iLogic CREATE the parameters if they do not already exist?  I think it would be something added below the "Catch..." just cant seem to figure out what it needs to be.

'look for custom iproperty and try to set it
Try
iProperties.Value("Custom", sExtLength)=Round(SheetMetal.FlatExtentsLength, iRoundValue)
Parameter("SM_Length")=Round(SheetMetal.FlatExtentsLength,4)

Catch
' assume error means not found and create it
customPropertySet.Add(Round(SheetMetal.FlatExtentsLength,iRoundValue), sExtLength)
EndTry

View 9 Replies


ADVERTISEMENT

AutoCAD Inventor :: ILogic Code To Create User Parameter?

Jul 29, 2011

I want to use iLogic to create User Parameters with Multi-Value lists filled with info from an excel spreadsheet. What is the code to create a new User Parameter?

i7-2720QM Dell Precision M6600, Win 7 Pro 64-bit, 8GB RAM
Autodesk Product Design Suite Ultimate 2013
Autodesk Vault Professional 2013

View 4 Replies View Related

AutoCAD Inventor :: User Parameter Expression List - Allow Custom Values?

Mar 21, 2013

Where do I find the "Allow custom values" option for a multi list parameter expression?

View 2 Replies View Related

AutoCAD Inventor :: Update User Parameter With Ilogic

Dec 28, 2013

Is it possible to update an existing User Parameter. While I can only  delete-create a new. In this case the connection is lost with BOMQuantity.

View 5 Replies View Related

AutoCAD Inventor :: Cannot Change Parameter Value For ILogic Unless User Is A Local Admin On PC

Aug 23, 2012

I have a users who cannot change parameter values for iLogic unless user is a local admin on the workstation. This machine has just been upgrade to Inventor 2013.

View 1 Replies View Related

AutoCAD Inventor :: ILogic Rule To Read Out User Parameter Of IPart

Nov 1, 2012

I've created a main assembly containing several ipart components. With the following rule I can read the model parameters, but not the user parameters of the iparts:

A = Parameter("Part1:1", "d0")
 
If I create a component, insert it in the main assembly and make it an ipart afterwards, the user parameters can be read out with ilogic. But if I insert the same ipart again, the user parameters can not be read out anymore. Model parameters are no problem. 

View 1 Replies View Related

AutoCAD Inventor :: ILogic - Modify User Form Parameter Read Only Status

Jan 9, 2013

Any way to modify a user form parameter's read only status using a rule?

I have a parameter that I want people to be able to edit when another parameter is set to true and to be locked if it's set to false. The only thing that comes to mind is have a rule that will just switch the value back automatically if the user changes it but it would be good if i could control the read only status.

View 3 Replies View Related

AutoCAD Inventor :: Create Multi-value Parameter With ILogic?

May 1, 2012

Is there a way to create a multi-value parameter with ilogic?

Inventor Pro 2013 (PDS Ultimate)
Vault Pro 2013
Windows 7 64
Xeon 2.4 Ghz 12GB

View 9 Replies View Related

AutoCAD .NET :: Create A User Parameter For A Dynamic Block

Feb 13, 2012

We have some dnyamic block share set of parameters, if we change a parameter's value, all block that reference this parameter should be change.we can do it by program.

but create user parameters for a dynamic block must be by hand, can we create a user parameter by code? another way is user global parameter. does AutoCAD Parametric function's user value can be share with dynamic block?

View 8 Replies View Related

AutoCAD .NET :: Create New (user) Parameter For Dynamic Block?

Sep 25, 2012

I would like to add a new (user) parameter to a dynamic block within my code. I have noticed that this is possible manually. But couldn't find how to do this in .Net. When this parameter has been created it would be necessary to fill in a value. So the parameter can either be a general parameter, that can be adjusted later or a (user/dynamic) parameter specific for the block.

View 1 Replies View Related

AutoCAD Inventor :: Add Boolean User Parameter?

Aug 24, 2012

Looking for sample VBA code to get all referenced documents from an assembly and add a boolean user parameter to each (parts and sub assemblies).  I have been trying to modify peices of code I have found on this forum and Mod the Machine, but have had no luck so far. 

There may also be standard content center parts in the assembly as well that I would like to somehow identify so I can skip over them.

View 1 Replies View Related

AutoCAD Inventor :: Delete User Parameter

Apr 22, 2013

Most of the time, I delete an user parameter without problem. But, in a part, I got an error for two of them and I don't understand why.  I create a new parameter and redirect all dependencies from the old one to the new. (oldParam.Dependencies.Count = 0).

But when I try to delete it, I've got an error. Also, when I try to delete it by the interface, I don't see the Delete option.

View 8 Replies View Related

AutoCAD Inventor :: How To Add User Parameter (Text Value)

Jun 10, 2011

Parameters with a text value, How do I add userParameter? In iLogic 
 
Examples. DoubleValue)

Sub Main()    

Dim oCompDef As PartComponentDefinition
oComDef = ThisApplication.ActiveDocument.ComponentDefinition
Dim oParams As Parameters
oParams = oComDef.Parameters
Dim uParams As UserParameters
uParams = oParams.UserParameters
strVal= uParams.AddByExpression!("strVal", 0.15, "mm")
iLogicVb.UpdateWhenDone = True
End Sub

View 6 Replies View Related

AutoCAD Dynamic Blocks :: Passing A Value From The Action Parameter To A User Parameter

Dec 1, 2013

I need to use the dimension created by an action-parameter as a variable in a user defined function but AutoCAD will not allow me (see attached).

How may I access the action-parameter's dimension ?

View 1 Replies View Related

AutoCAD Inventor :: Don't Have A User Parameter Linked To A Dimension

Aug 6, 2013

I'm having problems with the parameter menu. When I don't have a user parameter linked to a dimension in the model the parameter disappears out of the parameter menu.

View 2 Replies View Related

AutoCAD Inventor :: Changing User Parameter In Assembly

Apr 1, 2003

I have a part file ("part1.ipt") that has a user parameter called "Height". When I open this file as a part document, I can modify the "Height" parameter to change the height of the part. This functionality works great:

Set oPartDoc = oApp.Documents.Open(sPartFileName, True)
Set oParameters = oPartDoc.ComponentDefinition.Parameters
'change part height to 30 cm
oParameters.Item("Height").Expression = 30

Now, I am wanting to add this part to an ASSEMBLY document, then change the parameter to 30, but have been unable to do it.
I have this so far:

Dim oAsmCompDef As AssemblyComponentDefinition
Set oAsmCompDef = oApp.ActiveDocument.ComponentDefinition
Dim oOcc As ComponentOccurrence
Set oOcc = oAsmCompDef.Occurrences.Add(sPartFileName, oMatrix)

After I add all the parts, I highlight a part in the assembly pane, I click on FxParameters but I don't see the User Parameters for the part. Are the User Parameters not available when a part is placed into an assembly?

This assembly will have multiple parts added from the same file name, but the "Height" parameter needs to be modified for each occurrence.

View 5 Replies View Related

AutoCAD Inventor :: How To Export Text User Parameter

May 2, 2013

Is there a way to export a text user parameter?

View 8 Replies View Related

AutoCad :: Use User Defined Parameter To Drive Action Parameter?

Feb 7, 2012

it is possible to use a user defined parameter to drive a action parameter.

I have several polar and linear stretch actions i would like to drive from one parameter.

View 3 Replies View Related

AutoCAD Inventor :: User Defined Text Parameter In IPart

Aug 17, 2011

I am trying to make an iPart of a fitting where I can change the "Body type" and it will change all the parameters associated with that body type through iLogic.  Really I am just playing around in iLogic to see if this is something worth learning.  Back to the point, I would like to change a  multi-value user text parameter through the iPart table but I cannot find the paramter in the parameters tab. 

Since it is a user parameter I thought it would be in the "Other" folder but it isn't.  I do however have the other multi-value user number parameter in that folder, which makes me think that maybe I can't use the paramter in the iParts table? 

INV 2012 SP1
Windows 7 64 Bit
ATI FirePro V5800
14.0 GB RAM

View 9 Replies View Related

AutoCAD Inventor :: Export Multi Value Text User Parameter

Aug 26, 2010

I created a sketch that I would like to use in an iFeature.  The sketch dimensions are controlled with an ilogic rule referencing a multi value text user parameter, eg the text parameter pull down menu controls the size of the part.

Is there an easy way to get this parameter into an ifeature or derived part?

View 4 Replies View Related

AutoCAD Inventor :: Setting Multi-Value Parameter From Excel Named Range Values

Nov 20, 2013


I have a Multi-Value Parameter "MV" that I want to populate using a Named Range from an Excel file that is already populating other parameters for the same file.

I currently have the file working by populating "MV" by using the snippet from iLogic below...

MultiValue.List("MV") = GoExcel.CellValues("filename.xls", "Sheet1", "A2", "A10")

The reason I don't like this method is because if ever that range changes... all the iLogic code will have to be updated as well. How to set a Multi-Value Parameter using a Named Range from an Excel file? I assumed the below snippet would work but I am receiving

"Array was not a one-dimensional array." as an error. 

MultiValue.List("MV")=GoExcel.NamedRangeValue("Named_Range_Value")

View 4 Replies View Related

AutoCAD Inventor :: User Parameter Driven Text Height - 2012?

May 15, 2012

We are having issues with text height and variations depending on how the text is added.

I am currently adding etching to sheet metal parts by using the user parameters (which are driven by 3rd party source, excel file) and using a cut extrusion -1mm.

We have developed a marco which detects the shape of each letter and adds etching to our sheet metal program manually. We do this to get rid of the double lines when you cut text into a part. Our process is design in Inventor, unfold then convert to DXF 2004, where we import to our SM programming package (Radan).

I have noticed that when using 10mm simplex if the text is driven by parameters and 10 point text is selected the charecter height is 9.9928mm, however if the text is added manually it measures 10mm exactly. Why is this happening? It is probably of no concern to most, but we would need to add extra charecters to our macro to account for the descrepency, and in turn would take the macro longer to run.

When the text is added by user parameters, you can briefly see the 10mm text height flash to 9.99mm when finishing the edit sketch. Changing this to 10mm again has no effect.

what is causing this, or have any alternative ways of adding 10mm simplex single line etching to a dxf from an Inventor 2012 SM part?

View 5 Replies View Related

AutoCAD Inventor :: Cleaning Up Models By Deleting Obsolete User Parameter

Jul 4, 2012

I have created a large complex assembly that is parametrically driven by a skeletal sketch ipt by means of an embedded excel spreadsheet.

I am cleaning up the models  by deleting obsolete user parameters. But there is one that will just not give me the option to delete it.

I have interrogated the model inside and out but can not find anywhere that this parameter is still being used.

I go into the Parameter Dialogue Box (ƒx) and hover the cursor over the parameter and there is nothing that apears that indicates theis parameter is used anywhere in the model.

Is there an iLogic routine or some other method that will allow me to run a check or a search through the model that will point me to where the parameter might still be lingering.

I have attached a JPG if it will make things clearer.

RHRT_1 is the Parameter I am trying to get rid of.

BTW. The Models and Assemblies I create are guarded by Proprietry Laws so I am unable to send a copy to anyone.

Inventor 2012 Professional

View 1 Replies View Related

AutoCAD Inventor :: Add Item To Multi-Value-List Of User Parameter (2012 API)

Jan 3, 2014

IV2012 API with VB:

How can i add an item to a Multi-Value-List of an existing User Parameter in Inventor2012 (Accessing API with Visual Basic) ?

My idea is for example:

uParams.Item(i).ExpressionList.AddItem(As String)

The problem is, that such a function "AddItem" doesn't exist.

View 4 Replies View Related

AutoCAD Inventor :: Recently Used Values / Parameters In Dimension Dialog / Width Parameter List

Jan 10, 2012

if it is possible to increase the number of recently used values/parameters in the dimension dialog, during part sketching. For one part, I use approximately ten parameters that will be used repeatedly. When I'm done with one sketch and start with the next, only the last five parameters are in the recently used parameter list. (Create dimension --> select arrow on right side of dialog, see attachment Dimension_Dialog.jpg, excuse me for the poor quality ). It would be much more comfort to have more parameters in this 'recently used'-list.

Furthermore I'd like to know if it's possible to widen the parameter-list. In my case I've several parameters that start with the same prefix, followed by a differentiating suffix. When I create a new dimension, select the arrow on the right and select 'List Parameters', I have to adjust the width of this dialog every time to see the entire parameter. (see picture Dimension_parameters.jpg)

View 1 Replies View Related

AutoCAD Inventor :: Circular Pattern With User Parameter Controlling Angle Of Notch

Oct 13, 2013

I am setting up a family of parts that consist of a round disc with a fixed OD and a circular pattern of notches cut into the OD. The notches must go to a certain depth from the center, so those parameters are set. My problem is that I need to control the amount of material left between the notches, along the OD, after the pattern is done. Given the fixed parameters of the major OD, minor OD (3.5" in this case) and number of notches, the only way to control the amount of material between notches is to change the angle. When I set up the sketch to do the notches, I can only get a fully constrained sketch if I assign a specific angle  to the notch. I need to be able to set it up so that the angle of the notch varies so the end result is a specifc amount of material left after the circular patter is completed.

In the attached PDF, I show what I have done so far. In this case the OD of the part is 4" and the diameter of the notch at it's closest to the center is 3.5". So basically, I end up with a driven parameter of 0.443. If I assign this value the parameter of d14, I need to make it equal to a ratio of another parameter (let's call it d15) so that d14 = d15*2.. This can only be accomplished by changing the angle.

In my family, the major OD and minor OD remain the same, but the angle must change to retain a specific amount of material between the notches  when the number of notches is increased or decreased.

Is there an iLogic rule I can write to control this?

View 6 Replies View Related

AutoCAD Inventor :: ILogic Sort Values

Feb 20, 2013

I have an iLogic rule that populates the fields shown below in our title block. The DIM. Values are strings set with H,W,L values. This works well, but I have an additional need to sort these values in ascending order, so the smallest value is first followed by the next largest and finally the largest value. (4.000x5.000x14.000). I haven't had much luck finding any information about how this can be done. I did however come across some code here that someone else was using for a similar feature.
 
Dim sizes As New List (Of Decimal)sizes.Add(bH)sizes.Add(bW)sizes.Add(bL)sizes.Sort()D1 = sizes(1)D2 = sizes(2)D3 = sizes(3)

This is what I have been attempting, though it does not work. I get the following error "Index was out of range. Must be non-negative and less than the size of the collection. 

Parameter name: index". I'm not sure if my list type is correct (Decimal), but no matter what I choose it fails. The (bH,bW,bL) are the actual block dimensions pulled from the .ipt file. Once sorted I want the values of each position (1),(2),(3) to be assigned to (D1),(D2),(D3) so I can place them in my title block in the correct order.

View 3 Replies View Related

AutoCAD Inventor :: Round Parameter Using ILogic?

Sep 20, 2011

how to round a parameter using ilogic.

For example. I have Roperev=Roperev_1. Roperev_1 is determined by an excel equation. I need Roperev to produce a nominal number because this parameter dries a coil revolution and I need the revolution to be a whole number.

I can not just round the excel result because the excel result needs to be multiplied by 2.53 to get the resultant for Roperev_1

View 9 Replies View Related

AutoCAD Inventor :: Using ILogic To Change Parameter

Mar 26, 2013

When I import a part from content center, a tube in this case, I get a length parameter called <PL>.

I am using this parameter in the parts lists, so it shows "=Outer diameter x thickness x <PL>"

However I don't want trailing zeros, leading zeros or units string to be shown.

I know I can open the parameters window, right click the parameter, then click custom property format and then uncheck these boxes and its fine.

But I want to know if there is a smarter way to do this, like creating a rule to execute on all the parts?

I have around 500 pipes with the parameter <PL> that needs to be changed.

View 6 Replies View Related

AutoCAD Inventor :: Pass Parameter To DLL Using ILogic

Mar 26, 2013

I have built a vb interface using a tutorial from AU. Now I would like to do the same without the interface.

Inventor uses ilogic to pass parameters to the dll - the dll does the number crunching & returns values to Inventor - no interface required.

The tutorial uses an OK button to fire values back & forth - how can I do this without a button? I would like this to fire in the background without a form appearing.

View 4 Replies View Related

AutoCAD Inventor :: Use IProperty As Parameter WITHOUT Using ILogic?

Jul 22, 2013

I know how to get a parameter into my list of custom iProperties.What I want to do is take the iProperty lbmass and add it to the list of user parameters.  Is there any way to do this without using iLogic?

View 8 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved