AutoCAD Inventor :: Convert Model Parameter To Reference Parameter?

Oct 2, 2012

I need to convert a model parameter to a reference parameter thru the API.

I saw this item discussed in the group before, but I cant find the thread.

View 4 Replies


ADVERTISEMENT

AutoCAD Inventor :: ILogic - Model / Reference Parameter

Apr 12, 2013

I wish I perform the following code with iLogic. Is it possible to change a model parameter to a reference parameter?
 
If My_Expression Then' My dimension "d0" is a Driven Dimension' or' My dimension "d0" is a Reference ParameterElse' My dimension "d0" is NOT a Driven Dimension' or' My dimension "d0" is a Model ParameterEnd If

View 9 Replies View Related

AutoCAD Inventor :: Finding Reference Parameter In IPT?

Jan 7, 2014

Is there a way to identify what sketch or Solid a reference parameter (d0, d1, d2 etc) is in / on.

View 3 Replies View Related

AutoCAD Inventor :: IV2012 Sp1 - Delete Unused Parameter Takes 4-5 Seconds Per Parameter

Dec 23, 2011

I have user parameters that are no longer needed and are not being used anywhere.  They each takes 4-5 seconds to delete, prior to 2012 this would happen instantly.

IV2014 SP1 64bit
Dell Precision T7500, Geforce GTX 480, DirectX11 306.97
SpaceExplorer 4.04, 3DxWare 3.12.2
Twin Intel Xeon E5506 2.13GHz, 12GB RAM, Win7 Pro SP1 64bit

View 6 Replies View Related

AutoCAD Inventor :: Finding Parameter Reference To View Representations?

Sep 27, 2012

I created view representations in my assembly, for example a column with k-polates and base plates, the column is a FG part, so now i create drawings and place views on that drawing, what i am askign for is I want to place the name of the view representation in my view label as a paramater so in the event i change my view names in my model they update in my drawing, this is important because i can create a cross referance to my 3D DWXF file views.

View 4 Replies View Related

AutoCAD Inventor :: Reference Parameter Measuring Between Two Parts In Assembly

Jul 31, 2012

I need to assign the dimension in my screenshot to a parameter so I can use it to drive another assembly. However, I can't find any way to capture it in a usable manner.

In the screenshot I have an associative part inserted that contains only a sketch with the projected line and point that I wish to measure between, but the geometry in the sketch does not update when the model geometry changes. This seems to be normal behavior?

View 3 Replies View Related

AutoCAD Inventor :: Reference Parameters In IRule That Value Of Parameter A Determines Value Of B

Nov 22, 2012

I want to reference parameters in an iRule in such a way that the value of parameter A determines the value of parameter b.

In this case i want to reference the dimensional height of a UC beam into a parameter <UC_HEIGHT> and then allow this to determine the value of uc designation size in a parameter <UC_DESIGNATION>

This would be useful because instead of typing the uc designation of a beam into the part description or matl. list i can just reference a parameter.

Is this possible? Iv tried an iRule along the lines of

if parameter (uc height) = xxx.x then parameter (uc designation) = 'custom test'

but get error messages

View 3 Replies View Related

AutoCAD Inventor :: Set Parameter For End Value Of Parameter Animation

Dec 19, 2011

I got a deadline for my project, but I got a big problem:

"I cannot set the "parameter" for the End Value in Parameter Animate dialog"

For easy understand, let's see a example:

1. I got a part which has two parameters named: "A" and "MaxA"
2. I animate Favorited parameter A.
3. The End Value is MaxA_ (Everything is ok)
4. I finish Studio environment, then I change parameter MaxA_ from 200 mm to 400 mm
5. I turn back to Studio environment, the End Value now is "200 mm" (I want this will be MaxA_, so I can animate the flexible parameter). 

show me how to keep the end value will be "MaxA_" after I change parameter? 

View 3 Replies View Related

AutoCAD Inventor :: Changing Model Parameter Tolerances?

Nov 11, 2011

Is there a way to change the model parameter tolerances thru the API? I haven't seen this issue in the discussions. I've found the   parameter.tolerance  property, but it looks like it only returns the tolerance, Is there a way to set the tolerance?

View 1 Replies View Related

AutoCAD Inventor :: Ipart - Standard Parameter Column Change Depending On Custom Parameter Column

Jan 3, 2013

I am trying to publish to the CC a guide rail. The vendor of the rail gives me the option of entering the desired length of the rail. After that he gives me the option to choose between the length that I entered and a shorter and longer standard length witch can be delivered faster.

I want to do the same thing with my published part, but I cannot make a key parameter to change depending on the entered custom parameter. I want the user to make the next steps when inserting from the CC: 1- select the size of the rail; 2-select the type of the rail; 3- enter the desired length of the rail; 4- choose between the desired length and the 2 recommended lengths (I need these 3 lengths to be shown)

Is this possible?

View 9 Replies View Related

AutoCAD Inventor :: Model Parameter Text In Custom Symbol

Jun 27, 2012

Just installed 2013 Pro x64 and I'm doing a little testing. Using Tube and Pipe, I created a few mock pipe runs which are named according to a unique line number. When clicking on the Iproperties of any of these pipe runs, I can see that the value of model parameter "Part Number" now includes the name of the top level assembly and the line number, which is the name I assigned to the pipe run when I created it (see Fig 1 attached). Then in IDW I created a user defined symbol which contains text that I have directed to extract value of "part number" from the model properties, and fill in my symbol with that value (see Fig 2). The problem is, when I tag the pipe run with my custom symbol, the value in the symbol remains blank, instead of giving me the value of "part number".  WHAT am I missing??

View 3 Replies View Related

AutoCAD Inventor :: How To Make Model Adjust Correctly When Parameter Changed

Dec 13, 2011

I have a school project due tomorrow and I am almost completely finished. Except one part says that "Model adjusts correctly as __ varies". When I change a parameter, only that parameter changes and the rest of the part remains the same. I'll attach the assigment. I'll attach my work also if requested.

View 9 Replies View Related

AutoCAD Dynamic Blocks :: Passing A Value From The Action Parameter To A User Parameter

Dec 1, 2013

I need to use the dimension created by an action-parameter as a variable in a user defined function but AutoCAD will not allow me (see attached).

How may I access the action-parameter's dimension ?

View 1 Replies View Related

AutoCad :: Use User Defined Parameter To Drive Action Parameter?

Feb 7, 2012

it is possible to use a user defined parameter to drive a action parameter.

I have several polar and linear stretch actions i would like to drive from one parameter.

View 3 Replies View Related

AutoCAD .NET :: Database Parameter In Batch Process - By Reference?

Nov 21, 2012

I have a master batch process which comprises several steps each of which will change the database. I am gettting the database once, then pass it thought the subsequent steps. Simple example in pseudo

void BatchAll(){
database db = new database
BindXref(db)
PurgeAll(db)
DoSomethingElse(db)
save dwg
}finish BatchAll

Should the database db be passed by reference (ref db)?

View 4 Replies View Related

Revit :: New Project Parameter To Reference A Data Set?

Dec 30, 2011

How do I set up a Project Parameter to reference a txt file as a data set?  (the same way CSI division codes are referenced)

View 4 Replies View Related

Revit :: Reference Level Parameter In Cable Tray Schedule?

Dec 28, 2011

 I need to add "Level" into my Cable Tray schedule; we need to sort the cable trays lengths by floor level.  However, "Level" is not listed as one of the available fields, even though level information (show up as "Reference Level)  is one of the constraints in the cable tray model.

View 1 Replies View Related

3ds Max Animation :: Wire Length Parameter Of Taper Object - Illegal Self-reference In Controller Script

Nov 28, 2011

I try to wire the length parameter of a taper object to the local Y-Position values of another object. It works fine until I reload the file. I get an MAXScript Wire Controller Exception error:

--Runtime error: Illegal self-reference in controller script

...and the parameter-wire dialog opens. The desired functionality returns by clicking the Update Button and everything works fine again.

View 1 Replies View Related

Revit :: Possible Convert Numeric Parameter To Text

Jul 26, 2012

Is it possible to convert a numeric parameter to text so i can add it to another text feild? I cant seem to find a way to do it.

View 2 Replies View Related

AutoCAD Inventor :: Control Parameter With XML?

May 27, 2012

in Inventor 2010 we can save and load iLogic Paremeter with *.xml and just in my opinion we can control parameter using *xml or html. It's right or false?

how to control Inventor parameter with *.xml?

View 2 Replies View Related

AutoCAD Inventor :: Generating A Parameter

Oct 26, 2012

I need to extrude a simple shape between two planes and then get the length as a parameter. Is there anyway of generating this? All I can find is a parameter for the angle of the extrusion.

View 3 Replies View Related

AutoCAD Inventor :: How To Change G_L Parameter From In To Mm

Aug 24, 2013

I have generated frame that has 100 members in it. Is there a quicker way of changing G_L unit to a mm so that I don't have to go into all 100 parts to change the custom properties?

Also I do not need unit string to be appear in my BOM.

View 9 Replies View Related

AutoCAD Inventor :: Dimension And Parameter

Apr 14, 2009

I set a dimension to a 2dline. The dimension is automatically added to Model Parameters. How can I find , by code, the line which length is driven by the parameter ? Or, starting from the line find the parameter which indicate its length ?

::GetDependents(), nor ::GetDrivenBy(), nor ::GetParent() gives me the answer.

View 7 Replies View Related

AutoCAD Inventor :: Get Parameter Value From DWG File

Aug 6, 2012

I'm trying to get a parameter value from an Inventor .dwg file, but I keep getting an error saying the file is not found. I use this same code all over the place between different parts but its the first time I'm tried it using a dwg. Can you not access an Inventor .dwg parameters using iLogic .

MsgBox(Parameter(ThisDoc.Path & "MyDrawing.dwg", "Customer")) 

View 1 Replies View Related

AutoCAD Inventor :: Using Parameter In IProperties

Jan 6, 2014

Sometimes I change the dimensions of a material I use but then I have to open Iproperties and change the description by hand. This can create problems as you can understand especially when I forget to update the Iproperties.

Then I had the thought to automate it. Lets take a steel bar as example. I have thickness and width as parameter, both are exported and available under IProperties/Custom. But they show as 200 mm and 10 mm. I would like to loose the units. I tried also UL but then it reads 200 ul and 10 ul.

What I like to get are just the numbers, no units. I like to use it to create this  "steel bar 200x10" where the 200 and the 10 are linked to the Parameter and will change when I change the dimensions av the steel bar.

View 9 Replies View Related

AutoCAD Inventor :: How To Get Parameter From IPT File

Aug 8, 2012

I created a *.iam file. And from this asembly file, I need run some rules in *.ipt file.

I use

Parameter("PartA:1", "d12") = d12

to give d12 parameter in my assembly to d12 parameter in *.ipt. It works.

But I need get parameter in the *.ipt file after running the rules in *.ipt.

so, I put 

d13 = Parameter("PartA:1", "d13")

following above line.

But everytime, I just be able to get the result before *.ipt run the rules, not after.

I noticed the rules in assembly were compeletely run, then run the rules in *.ipt. So, the result is not correct.

I am using Inventor 2009 with ilogic. XP OS.

Autodesk Inventor Professional 2013 (64 Bit) SP2
Windows 7 Professional Service Pack 1
Intel(R) Xeon(R) CPU E5645
12.0 GB Memory

View 9 Replies View Related

AutoCAD Inventor :: Set Material As Parameter?

Jan 31, 2012

I would like to have the material, color etc. as parameter so i can change it with an ilogic form. 

In this video you can see what i mean:

[URL]

When I make a ilogic form i can only select parameters and iproperties.

View 4 Replies View Related

AutoCAD Inventor :: Use Filename As Parameter?

Nov 8, 2006

Is there a way to use the filename to drive the parameters of the file?

Example: I have a cube that is called 4x4x4.ipt its dimensions d0,d1,d2 are 4,4,4 respectively. I want to rename it to 4x4x6.ipt and have the dimensions d0,d1,d2 resize to 4,4,6.

View 9 Replies View Related

AutoCAD Inventor :: Custom VBA Function In Parameter

Jan 31, 2013

I've got a custom VBA function that works perfectly when called from a parameter in my part.

However, when in the context of my assembly, there is no error, but the function no longer runs, and the parameter text is red.

Apparently, the function is no longer in context?

I've heard of external rules, but have never implemented one.

Is there a way to declare my function and keep it in context regardless?
 
Public Function BumpHeight(dblHeight As Double, dblMember As Double) As Double Dim X As Integer X = 2 If dblHeight > dblMember * 2 Then BumpHeight = dblHeight Else BumpHeight = dblMember * X End If BumpHeight = BumpHeight / 2.54 End Function
Here is the Parameter:

 VBA:BumpHeight(ValanceBackBumpoutHeight;ValanceMemberSize) * 1 in

Update: (problem better defined)

What seems to be happening is that once I insert the part into an assembly, it creates a new blank copy of the parts' modules in VBA and the functions no longer work.

If I go to the VBA editor, 

There are now two copies of my part listed in the browser tree, but the new one is blank.

If I paste in my function to the new one, it will work until I return to the parent assembly.

Next time I come back to the part, it will have a new blank set of modules.

This appears to continue indefinitely...

see the attached screenshot.

At this point there are only 2 copies of the DocumentProject. The original still contains my functions, but the new one is blank.

I need these functions to work in order to build my model.

View 1 Replies View Related

AutoCAD Inventor :: Round Parameter Using ILogic?

Sep 20, 2011

how to round a parameter using ilogic.

For example. I have Roperev=Roperev_1. Roperev_1 is determined by an excel equation. I need Roperev to produce a nominal number because this parameter dries a coil revolution and I need the revolution to be a whole number.

I can not just round the excel result because the excel result needs to be multiplied by 2.53 to get the resultant for Roperev_1

View 9 Replies View Related

AutoCAD Inventor :: Pattern Subassembly By Parameter

Sep 5, 2013

In my head assembly I have a subassembly that has derived parts from my skeleton. My skeleton (part ending with skt in the picture) is in the subassembly.

In this subassembly I made a view representation: NoSKT..When this is activated the skeleton is hided (see picture).If I now make a pattern of this subassembly in my head assembly with for example a parameter from my embedded excel or a parameter in inventor "quantity = 2" inventor will add 1 element with the same view representation. Still no problem.

The problem is now when I change the parameter. If I change the quantity to for example 3, the view representation of the third element is gone and the skeleton will become visible.I have many parts like this in my head assembly and quite a lot of patterns. Which means a lot of skeletons become visible. Is there a way to stop this from happening?

View 2 Replies View Related