AutoCAD Civil 3D :: Structure Name Slash Character?

Jul 14, 2013

The structure name under C3D strucutre properties dont allow '/' character.

Eg:- If I want to name a structre like MH/5899/05/01, this is not possible if I am entering from C3D strucute properties dialogue box.

But can do from Autocad Strucutre properties or via lisp routine.

The '/' character changes to '_' (underscore) if taking C3D structure proprties.

Also sometimes close and reopen the drawing change the '/' character to '_' for some structures.

View 5 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: 2012 - Pipe Structure Editing - Changing Preset Lists For Structure Sizing

Nov 4, 2011

We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers.  The structure list shows sizes we do not use and we would like to modify them.  However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.

I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.

Here is what the file looks like:

<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">

<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>

I tried modifying the last line replacing 2550 with 3600.

I also tried adding a line  <Item id="i7">3600.0000</Item>

I saved the XML file and restarted the program with nothing changing that I can see.

Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Get Pipe Structure To Be Sphere Like Null Structure

Feb 12, 2008

One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.

View 4 Replies View Related

AutoCAD Civil 3D :: Concentric Structure To Eccentric Structure

Apr 30, 2012

I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.

View 2 Replies View Related

AutoCad 2D :: Unable To Stop Slash ( / ) From Becoming A Fraction

Feb 8, 2012

We are working in Autocad lt 2012 and in one particular drawing we can't stop the slash (/) from turning into a fraction line . IE the date 08/02 becomes a fraction 8 over 2.

View 9 Replies View Related

AutoCAD Civil 3D :: Structure Insertion To Pipe

Jul 31, 2012

I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.

This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.

View 7 Replies View Related

AutoCAD Civil 3D :: Make Structure Table From DS

May 21, 2012

Is it bad to make a structure table from a DS? I find I get missing data when I do.

View 2 Replies View Related

AutoCAD Civil 3D :: Structure Labels In Profile?

Feb 12, 2013

I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?

View 1 Replies View Related

AutoCAD Civil 3D :: Structure Label Layering

Feb 19, 2013

I have my pipe networks data referenced into my Utility drawing and I'm trying to add labels to my structures (catch basins, manholes...). I made styles and selected C-TEXT as the layer for the label, but for some reason they're all on layer 0.  The 0 layer is frozen in my viewport but the C-TEXT layer is not, and the labels aren't showing up (but when I thaw 0 they show up)!  I can see them in model space and when I click on each label the properties shows it's on the C-TEXT layer...

View 2 Replies View Related

AutoCAD Civil 3D :: MES Top Elevation In Structure Table

Dec 16, 2010

Is there a way to show the MES Top Elevation as blank or a dash? It would be great if I could make an expression but without the use of text strings in the expression editor, I don't know how to accomplish this without using wipe out boxes over the elevations.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Connections To A Structure?

Jul 30, 2010

Is possible to connect a pipe to a structure and not have in connected to the structure center? 

I have some two-tiered structures that are 108" dia for the bottom section and 48" dia for the top section.  The 48" top section is not centered I need my small 12"-15" pipes to connect to this section of the structure.

Civil 3D 2014
Win 7

View 2 Replies View Related

AutoCAD Civil 3D :: Expressions In Structure Labels

Feb 21, 2013

We have a Structure Style that places a hidden block at the invert of the structure which uses an expression to accomplish Placing the invert text below the structure. (please see attached).

This particular expression was written for a 1"=30 Horz. & 1"=5' Vert. scale and we use it to label our structures in the profile view.

It works great for the 1:30 scale scenario but we also produce 1:20 & 1:50 scale plan / pfl sheets.

3 label styles can be used to accomplish this but would like to create one that would work for all three scenarios if this is possible? (Goal is 1 expression & label style as opposed to 3 of each).

I thought I had it solved & have tried various formulas but can't seem to get it to recognize the various distortions in scale. (The constant being the 5' vertical dimension for all 3 options)

50/5=10

30/5=6

20/5=4

C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit

View 9 Replies View Related

AutoCAD Civil 3D :: Structure In Profile View

May 5, 2013

how can i set the smub of a structure at the crown of a pipe not at the invert?

View 3 Replies View Related

AutoCAD Civil 3D :: Specific Structure Label

May 16, 2013

I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation. 

Actually, I thought it was going to be pretty simple, just by doing: 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

or 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Structure Rim Insertion?

Apr 10, 2012

I have setup a reference surface for all of my structures and a sump depth of 0. All of the rims are being inserted about 1.6' above my reference surface. I am not able to grip any of the rims and lower them. It will not allow me to do so. Even if I grip the invert and make the structure extremely deep, I still cannot change the rim. I've had this problem in the past but don't recall how to correct or what I've done wrong in the setup.

View 9 Replies View Related

AutoCAD Civil 3D :: Null Structure Description

Apr 18, 2011

We use a lot of Null Structures but then give them different descriptions.  More often than not when I give them a description and then get out of the drawing, the next time I get back in it says "Null Structure" again.   How can I keep the description the way I want it?

I know that "the right way" would be to have specific structures made for each of these items, but that doesn't seem to be a priority at my company..

View 9 Replies View Related

Photoshop :: Slash Special Effect

Jul 4, 2006

I don't know how do an effect of a slash like the one in this game

screenshot

This is for a 2d fighting game so it seems rather difficult for me to make something like this.

View 9 Replies View Related

Photoshop :: How To Create A Slash/rip Effect?

Jun 12, 2005

creating like a slash or ripping effect? I am creating a graphic where I want part of the graphic to look as it is peeling away after it was slashed.

Its a small photo, but I am looking to create something to that effect.

View 1 Replies View Related

AutoCAD Civil 3D :: Pipe Structure With Sloped Bottom?

Jun 8, 2012

In the Pipes Parts Builder is it possible to create a stucture that has a sloped bottom? I would like to try and built a trench drain structure.

View 1 Replies View Related

AutoCAD Civil 3D :: Expression In Structure Labels For Survey

Sep 6, 2013

I am trying to make a single point label style that will return a blank line in the label if no data is provided.
 
The way i have it coded now my label for a structure with only two inverts comes out looking like this:

STCB 500 Rim=300.00
12" CONC N IE=295.00
12" CONC S IE=296.00
IE=300.00
IE=300.00
 
I would like the number of lines returned to match the actual number of inverts in the structure and leave out the place holders.:

STCB 500 Rim=300.00
12" CONC N IE=295.00
12" CONC S IE=296.00
 
I can work around this by having a label style for each number of pipes, but i would also like this code to be inseted into a table style and in that case i don't know of any way to assign multiple styles to one table.
  
My current code looks like this:
RIM=<[Point Elevation(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[1 SIZE(CP)]> <[1 TYPE(CP)]> <[1 DIR(CP)]> <[IE TEXT(CP)]><[1 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[2 SIZE(CP)]> <[2 TYPE(CP)]> <[2 DIR(CP)]> <[IE TEXT(CP)]><[2 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[3 SIZE(CP)]> <[3 TYPE(CP)]> <[3 DIR(CP)]> <[IE TEXT(CP)]><[3 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[4 SIZE(CP)]> <[4 TYPE(CP)]> <[4 DIR(CP)]> <[IE TEXT(CP)]><[4 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
LADDER <[LADDER(CP)]>
 
The problem is that 1 INV-4 INV are being defined by an expression that reads like

{Point Elevation}-{1 MD}

so when no data is intered for my UDP "1 MD"  it returns the point elevation. I want an equation that says if rpoitn elevation -measure down=point elevation then no data is shown.

View 5 Replies View Related

AutoCAD Civil 3D :: Insert Structure In Pipe Network?

Dec 14, 2013

I am working on an existing Pipe Network.  I have a location where I have already placed a pipe and filled in the correct parameters for this pipe.  But I realize now that there is a concrete headwall near the end of the pipe.  So I was trying to insert the structure at the midpoint of a line I have created for OSNAP reasons so it would create the structure at the specified location.  The problem is when I move the structure to create at this location, the "Break Pipe Marker" goes away and only shows when I am at a different location along the pipe.  So I wanted to see if there was a command or feature to use to tell the software I want to place this structure at a specified location along this one section of pipe. 

I wanted to see what my options were.  I know I can grab one end of the pipe and move it to the location and then add the structure and pipe from there.  But I did this insertion under different circumstances and it broke the pipe into 2 sections while still keeping the same and adding a (1) after it, which is pretty useful when reading printouts and showing that this is actually one pipe instead of 2 pipes.

C3D 2014 SP1
DELL Precision T3600
Intel Xeon E5-1650 @ 3.20GHz
NVIDIA QUADRO 4000 Dual Monitor
32 GB RAM / Win7 Pro 64-bit

View 7 Replies View Related

AutoCAD Civil 3D :: Part Builder - Structure Height

Jan 24, 2010

I am trying to learn Part Builder to create a custom inlet structure. I am able to build the part in Part Builder so it looks like it should and seems to work correctly when I change part sizes. I run into trouble when I try to change the model parameter for Structure Height (SBSH) to a formula invovling Rim to Sump Height (SRS). When I do this and then go to Edit Size Parameters, I get an error " one or more calculations have failed". It does not seem to make any difference what formula I use for SBSH or what size parameter or model parameter SBSH was set to before I entered the formula.

I am able to save the part without any other error messages, however, when I look at the .xml file, SBSH is a constant and not the formula I entered. I can edit the .xml file to enter the formula that I want but still the part does not function properly in a drawing.

I can make a pipe network using the new structure, however, the pipe inverts are not the same as the sump elevation of the structure. They are usually several feet below the sump. I can get the structure sump to match the pipe inverts by going to "Connected Pipes" under "Edit Structure Properties", highlighting the pipe invert elevation and then clicking "Apply". If you change the pipe using "Edit pipe properties" after this, the structure invert does not update as it should.

View 2 Replies View Related

AutoCAD Civil 3D :: Get Structure Label To Stop Flipping?

Oct 14, 2013

Is there a way that I can get a small angle between my leader and the landing? When I get to a certain angle, the text flips. I can't place the text exactly where I want it because of this. I've tried changing the Readability Bias angle in the label style but that didn't work.

View 2 Replies View Related

AutoCAD Civil 3D :: What Structure To Use To Model Yard Inlet

Jul 10, 2013

what structure to use to model yard inlet?

View 5 Replies View Related

AutoCAD Civil 3D :: Revit Structure For Cut And Cover Tunnel

Jul 6, 2013

We are currently designing a Highways project which includes a cut and cover Tunnel (dual 3 lane through goes underneath a signalized at grade junction). Navisworks will be used for clash detection of all disciplines. To clarify the cut and cover structure will be similar to a large box culvert. Although new to the software; the Highways team will be undertaking the Civil Highways design in Civil 3D.

My question is - what is the best Autodesk solution for the structure and associated retaining walls? Note at this stage we are unsure what all of the design components will be (e.g. pump room for drainage etc). Previously the Structures team would have produced a 2D design (however 3D modeling is a requirement).

I have seen on the internet Civil 3D and Revit Structures being used interactively (although it appeared to be incorporating bridges only). Is Civil 3D able to affectively model this structure and retaining walls within the subassembly composer? Or is the question more to do with how the Structures team will complete their design (i.e. reinforcement detailing / scheduling etc).

View 4 Replies View Related

AutoCAD Civil 3D :: Box And RCP Pipe Callouts In Structure Labels?

May 24, 2012

we have serveral situations when we need to label both box culvert pipes and round rcp pipes on the same junction box label.  what we cant do is have civil 3d differentiate between the two, it will either give us box labels or rcp labels but not both.  we are using civil 3d 2011, does 2012 offer this feature and 2011 doesnt?

View 1 Replies View Related

AutoCAD Civil 3D :: Profile Structure Label Wipeout?

Apr 11, 2013

I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?

View 9 Replies View Related

AutoCAD Civil 3D :: How To Customize Pipe Structure Inner Diameters

Aug 8, 2007

At the moment I'm trying to make a sewage pipe network, and I need something with a 7' diameter manhole. I'm trying to use Concentric Cylindrical Structures, and I'm not able to make or use a part size with an 84 in. diameter.

Is it possible for me to enter in my own value for that property, instead of having to use the pull-down menu?

View 4 Replies View Related

AutoCAD Civil 3D :: Wipeouts In Structure Table Cells

Jul 19, 2013

I have a drainage structure table for a leaching system. I used some expressions to calculate some of the leaching pool values for the Top Of Rings etc. When the expression is false I get a zero. The expression work as expected, and I anticipated manually wiping out the false value, but when I wipeout or solid mask the values in MS they don't line up in the view port. How to effectively wipeout structure table cells?

Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
64 Bit Win7 OS

View 6 Replies View Related

AutoCAD Civil 3D :: Leader Attachment To Pipe Structure?

Jul 25, 2012

I would like the arrowhead for the leader labaling my structure in a pipe network to attach to the outside edge of the structure.  Right now it attaches to the middle of the structure and is covered by the block representing my structure. 

View 9 Replies View Related

AutoCAD Civil 3D :: Structure Drag Call Out Leader

Aug 2, 2012

I have been trying for weeks and still cat get it to work. I am trying to make my drag out leader to look like a pline with a width of 0 on one side and a width of 4 on the other for civil 3d 2012. See attached .

View 4 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved