AutoCAD Civil 3D :: Linetypes For Pipes In Profile (Top And Bottom Line)
Jun 6, 2011
Requirement is to display pipes in profile with the same linetype ON TOP as shown in plan view, but bottom line of pipe must be continuous linetype.
Same problem as described here, 5 years ago [URL].......
I still do not see a way to control top and bottom pipe linetypes independently - using 2011.
View 3 Replies
ADVERTISEMENT
May 31, 2007
I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.
Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?
View 5 Replies
View Related
Apr 21, 2013
why when i mesure the pipe diam prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok
View 8 Replies
View Related
Sep 17, 2012
i need to transition from a proposed to a future linetype part of the way down my profile. It's the same surface, just that @ station XX+XX.XX it becomes future. I need it a diff linetype to faded back, for example. Is there a way to do that? I'm thinking my only option is two create two surfaces, one propsed and one future. My situiation currently is that I already have one complete surface and would like to know if it's possible.
View 9 Replies
View Related
Mar 12, 2012
I have two pipe networks and two profile views, one for storm and another for sanitary. I would like to show the crossing pipes on each of the profile views. When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display). Isn't there a way to display the styles for pipes different in each profile view?
C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM
View 3 Replies
View Related
Jun 22, 2009
I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.
View 5 Replies
View Related
Sep 17, 2013
How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.
View 9 Replies
View Related
Apr 5, 2013
Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view? see the screen shot of sketch of what I'm referring to.
View 2 Replies
View Related
May 15, 2012
In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile. I have that profile style set to not plot so this way I can leave it on all the time. This is all fine and well. I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something. How do I add an addition data band label to achieve this? Everything I have found only lets me have these labels at a specified increment set in the band style.
View 2 Replies
View Related
Feb 28, 2013
Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.
Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.
View 2 Replies
View Related
Apr 19, 2013
I've got a weird problem with pipes in 2014. When I edit a pipe (right-click Pipe Properties) and make a change, when I press OK or Apply, the pipe SIZE changes? It's still listed as a 300mm PVC, but it's being represented as a 410mm? Look at the attached image. The storm (green) shoes a 300mm pipe and 375. The 375 is smaller? The pipe style (as you can see int he image, is set to display the inside pipe walls.
Nothing is unique here about the pipe sizes, this is a stock pipe catalog. But the size doesn't really change, only how the pipe is drawn in the profile. I've never seen something like this before. It measures .418m instead of .3m.
View 3 Replies
View Related
Sep 6, 2013
I have a water and sewer line that run parallel for the most part. The sewer starts at 10+00 runs west and then turns north about 10+80 and parallels the waterline from that point on.
I want to show the sewer in the water profile as beyond and to reference the sheets to see for P&P information. This works fine.
When i go to show the waterline in the sewer profile it does not show up correctly it only shows up in the initial 80 feet of the sewer profile. Is this because the two alignments are not parallel with each other until that 2nd manhole?
See attached profile PDF.
View 8 Replies
View Related
Apr 30, 2013
How I have come to this question is through the process of trying to realistically show a hydrant in profile view. First off it it possible to create a completely vertical pipe in C3D? Also if you can, is it possible to show that in profile view? Basically, what I am trying to avoid is representing a fire hydrant pipe by creating some sort of custom cyclinder part in partbuilder. I have done this, but do not like the results.
Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
View 3 Replies
View Related
Sep 17, 2013
I have drawn in essentially a sewer pressure pipe (using gravity part network because I don't have time to setup the other) and I am using PVC pipe and null structures at the joints. I created the pipe network from a feature line with verticies at the grade breaks and every 10'. As you can see in the picture the pipes are lining up but I have these straggling lines on the profile.
View 2 Replies
View Related
Apr 20, 2011
Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.
View 4 Replies
View Related
Dec 5, 2012
I have pipe crossings shown in my profile. Only crossings (NO PROJECTIONS). So many elipises. I want to label them. Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation). I have accepted this (although it sucks).
Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label. Label type is "Entire Network Profile". When I do this, it labels not only the crossings but all projections. So I have a million labels chilling out in space, where I have no crossing.
View 1 Replies
View Related
Jan 10, 2013
So I have been getting a fatal error "INTERNAL ERROR: !dbobji.cpp@8743: eNotOpenForWrite" when I try to export to 2010 CAD.
I have worked out that it happens when pipes are displayed in the profile view.
View 7 Replies
View Related
Feb 12, 2013
Run profile on a self-intersecting street? The one I'm dealing with is a dead end 'P' shape. Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view. Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.
View 1 Replies
View Related
Oct 8, 2013
My colleague added parallel pipe networks and crossings to multiple SD profile views yesterday. Today, he came in, turned on AutoCAD, opened the drawing, and the parallel pipes and crossings were gone. The working folder had reset itself to nowhere so we reset the working folder and Data Shortcuts Folder, but that didn't bring them back. We can go into the profile view properties<pipe networks tab and turn the pipes and structures back on and override the styles, but that is basically redoing everything we did yesterday. Is there a way to avoid having to redo everything? Is there a way to avoid this from happening in the first place?
C3D 2013
Windows7 64 bit
View 3 Replies
View Related
Mar 23, 2012
We are currently using 2012 Civil 3D, and we have a issue with a drawing that not all the Pipes from the pipe network are displaying in the Profile, and even the pipe properties display box the lengths show up way too long and the stationing does not display correctly in this pipe properties box either.
The Big Twist is that we have 2 machines in the offices that will display the drawing correctly, in profile view and pipe properties display box has correct lengths and stationing. So we know it is not styles, etc.
Direct support has suggested we un-install all Autodesk products and reinstall them all again, we tried the repair, however this did not work. Any other way before we have to go through all this work, as we are looking a huge amount of downtime, and we do not think this is the issue. Perhaps a Civil 3D variable or Autocad variable is different?
View 6 Replies
View Related
Aug 15, 2012
What do I draw the existing pipes as that will be under the surface that I'm profiling? I have the surveyed invert points I'm assuming that won't be polylines? how to get the pipe to show at the proper elevation on the profile?
View 2 Replies
View Related
Jun 28, 2012
The intersection wizard makes dynamic EOP profiles based off of the cross slope from the centerline. Well the intersection tool doesn't always work with funky intersection layouts. Is it possible to manually create a dynamic EOP profile based on the cross slope from the centerline profile?
Civil 3D 2012
Windows 7, 64 bit
View 1 Replies
View Related
Jul 6, 2013
I seem to be having trouble changing the lineweight of my profile line. I have changed the line weight in the layer properties, in the Profile properties and tried changed the line weight in the pen style. Everywhere I could think I try to make the line thicker but when I plot, the line is still the same and difficult to distinguish from the grid blocks of the profile view.
View 3 Replies
View Related
Jul 4, 2012
I have a series of sheets, each with two viewports to show two plan views of a long road alignment. I arranged them to read bottom to top, as it goes up stationing, as we do with cross section sheets, but have been told by an outside reviewer that the sheets are confusing and should read top down.
How would you arrange them?
View 2 Replies
View Related
Sep 11, 2012
I have a profile view with the existing ground profile shown. The alignment the profile is referencing was stretched at the front and now the profile markers do not line up with the profile line. The profile line updated as it should have, but the markers did not.
See attached screen shot.
View 3 Replies
View Related
Dec 10, 2012
I'm doing a road project. i've got profile grades of existing left and right ditches. in some sections we're redoing the ditches so i've got proposed left and right ditch profiles. what i want to show is where i've got proposed ditch grades, i don't want to show existing ditch grades.
The new ditches happen intermittently on the road so i would need to be able to turn off the existing ditches at various places. is this possible without exploding my existing ditch grades?
View 9 Replies
View Related
Mar 1, 2013
I have a roadway alignment with FG profile and I want to place a feature line on the roadway centerline that represents the FG profile elevations.
View 7 Replies
View Related
Jul 15, 2013
is there a way to draw a line in the profile view and create that line into a feature line? and if there is can i project that line into the plan? i know that you can make a feature line in the plan and project that feature line into a profile view, just wondering if you could basicly do the reverse. i don't want to make a coridor.
View 4 Replies
View Related
Jul 6, 2012
we use three line road profiles. If there is a bus pullout or lane transition we show the curb profile based on centerline stationing. I'm able to generate a the corridor using a transition lane assembly from centerline and targeting a widened offset alignment or just a feature line. I can import the corridor curb feature line into a profile which would be a perfect solution, but it is all truncated. (i.e. no vertical curves) I can create a profile of the offset alignment, but the stationing doesn't match centerline.
How can I either generate a non trunidicated profile from the corridor for my curb profiles? How can create a design profile of a transition/pullout curb line that I can target and plot against centerline stationing?
View 4 Replies
View Related
Sep 24, 2013
I HAVE A 2D PROFILE (DWG FILE NOT CIVIL3D FILE) of a pipeline that shows invert of the pipe.
I want to have this pipe as feature line .
is there any way to convert this profile to feature line?
View 1 Replies
View Related
May 15, 2013
angle.jpg
How can I draw the bottom line, with an angle of 132 relative to the middle line?
View 6 Replies
View Related