AutoCAD Civil 3D :: Partial Parallel Pipes In Profile

Sep 6, 2013

I have a water and sewer line that run parallel for the most part. The sewer starts at 10+00 runs west and then turns north about 10+80 and parallels the waterline from that point on.

I want to show the sewer in the water profile as beyond and to reference the sheets to see for P&P information. This works fine.

When i go to show the waterline in the sewer profile it does not show up correctly it only shows up in the initial 80 feet of the sewer profile. Is this because the two alignments are not parallel with each other until that 2nd manhole?

See attached profile PDF.

View 8 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Parallel Pipes And Crossing In Profile View Disappeared

Oct 8, 2013

My colleague added parallel pipe networks and crossings to multiple SD profile views yesterday.  Today, he came in, turned on AutoCAD, opened the drawing, and the parallel pipes and crossings were gone.  The working folder had reset itself to nowhere so we reset the working folder and Data Shortcuts Folder, but that didn't bring them back.  We can go into the profile view properties<pipe networks tab and turn the pipes and structures back on and override the styles, but that is basically redoing everything we did yesterday.  Is there a way to avoid having to redo everything?  Is there a way to avoid this from happening in the first place?

C3D 2013
Windows7 64 bit

View 3 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile

Apr 21, 2013

why when i mesure the pipe diam  prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok

View 8 Replies View Related

AutoCAD Civil 3D :: Crossing Pipes In Profile?

Mar 12, 2012

I have two pipe networks and two profile views, one for storm and another for sanitary.  I would like to show the crossing pipes on each of the profile views.  When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display).  Isn't there a way to display the styles for pipes different in each profile view?

C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM

View 3 Replies View Related

AutoCAD Civil 3D :: Pipes Extending Beyond Profile?

Jun 22, 2009

I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.

View 5 Replies View Related

AutoCAD Civil 3D :: Drawing Pipes In Profile

Sep 17, 2013

How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile View?

Apr 5, 2013

Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view?  see the screen shot of sketch of what I'm referring to. 

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Data Bands For Pipes?

May 15, 2012

In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile.  I have that profile style set to not plot so this way I can leave it on all the time.  This is all fine and well.  I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something.  How do I add an addition data band label to achieve this?  Everything I have found only lets me have these labels at a specified increment set in the band style.

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Hatching From FG To Top Of Pipes - 2013

Feb 28, 2013

Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.

Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile Display - Size Changes

Apr 19, 2013

I've got a weird problem with pipes in 2014.  When I edit a pipe (right-click Pipe Properties) and make a change, when I press OK or Apply, the pipe SIZE changes?  It's still listed as a 300mm PVC, but it's being represented as a 410mm?  Look at the attached image.  The storm (green) shoes a 300mm pipe and 375.  The 375 is smaller?  The pipe style (as you can see int he image, is set to display the inside pipe walls.

Nothing is unique here about the pipe sizes, this is a stock pipe catalog. But the size doesn't really change, only how the pipe is drawn in the profile.  I've never seen something like this before.  It measures .418m instead of .3m.

View 3 Replies View Related

AutoCAD Civil 3D :: Display Vertical Pipes In Profile View?

Apr 30, 2013

How I have come to this question is through the process of trying to realistically show a hydrant in profile view. First off it it possible to create a completely vertical pipe in C3D? Also if you can, is it possible to show that in profile view? Basically, what I am trying to avoid is representing a fire hydrant pipe by creating some sort of custom cyclinder part in partbuilder. I have done this, but do not like the results.

Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450

View 3 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile Display - Straggling Lines

Sep 17, 2013

I have drawn in essentially a sewer pressure pipe (using gravity part network because I don't have time to setup the other) and I am using PVC pipe and null structures at the joints.  I created the pipe network from a feature line with verticies at the grade breaks and every 10'.  As you can see in the picture the pipes are lining up but I have these straggling lines on the profile. 

View 2 Replies View Related

AutoCAD Civil 3D :: Linetypes For Pipes In Profile (Top And Bottom Line)

Jun 6, 2011

Requirement is to display pipes in profile with the same linetype ON TOP as shown in plan view, but bottom line of pipe must be continuous linetype.

Same problem as described here, 5 years ago [URL].......

I still do not see a way to control top and bottom pipe linetypes independently - using 2011.

View 3 Replies View Related

AutoCAD Civil 3D :: Labeling Multiple Structures / Pipes In Profile View

Apr 20, 2011

Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.

View 4 Replies View Related

AutoCAD Civil 3D :: Single Line Manhole And Pipes In Profile View

May 31, 2007

I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.

Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?

View 5 Replies View Related

AutoCAD Civil 3D :: Pipes - Label Entire Network Profile / Want Crossings Only

Dec 5, 2012

I have pipe crossings shown in my profile.  Only crossings (NO PROJECTIONS).  So many elipises.  I want to label them.  Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation).  I have accepted this (although it sucks).

Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label.  Label type is "Entire Network Profile".  When I do this, it labels not only the crossings but all projections.  So I have a million labels chilling out in space, where I have no crossing.

View 1 Replies View Related

AutoCAD Civil 3D :: 2013 Crashing On Export To CAD When Pipes In Profile View

Jan 10, 2013

So I have been getting a fatal error "INTERNAL ERROR: !dbobji.cpp@8743: eNotOpenForWrite" when I try to export to 2010 CAD.

I have worked out that it happens when pipes are displayed in the profile view.

View 7 Replies View Related

AutoCAD Civil 3D :: Self-intersecting Alignment - How To Show Pipes In Profile View

Feb 12, 2013

Run profile on a self-intersecting street?  The one I'm dealing with is a dead end 'P' shape.  Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view.  Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.

View 1 Replies View Related

AutoCAD Civil 3D :: 2012 Pipes Don't Displaying In Profile / Works Correctly On 2 Computers

Mar 23, 2012

We are currently using 2012 Civil 3D, and we have a issue with a drawing that not all the Pipes from the pipe network are displaying in the Profile, and even the pipe properties display box the lengths show up way too long and the stationing does not display correctly in this pipe properties box either.

The Big Twist is that we have 2 machines in the offices that will display the drawing correctly, in profile view and pipe properties display box has correct lengths and stationing. So we know it is not styles, etc.

Direct support has suggested we un-install all Autodesk products and reinstall them all again, we tried the repair, however this did not work. Any other way before we have to go through all this work, as we are looking a huge amount of downtime, and we do not think this is the issue. Perhaps a Civil 3D variable or Autocad variable is different?

View 6 Replies View Related

AutoCAD Civil 3D :: Generating Existing Drainage Pipes In Profile View 2011

Aug 15, 2012

What do I draw the existing pipes as that will be under the surface that I'm profiling? I have the surveyed invert points I'm assuming that won't be polylines? how to get the pipe to show at the proper elevation on the profile?

View 2 Replies View Related

AutoCad :: Make Partial Open (saddled) And Partial Box (housed) Stringer?

May 16, 2013

how to make a partial open (saddled) and partial box (housed) stringer?

The only difference is that the open treads do not extend but are the same length as the box treads.Partial_Open_into_Box_Stair.gif Using Autocad Architecture 2012.

View 0 Replies View Related

AutoCAD Civil 3D :: Partial Load Cuix

Jul 5, 2013

Messing with creating a Partial CUIX ribbon, new to this with using macros, I have a general understanding. Created a pulldown for creating existing electric polylines, I have macro setting both to the same layer, but not sure how to get so linetypes are different for both. One would be underground and the other would be overhead.

View 1 Replies View Related

AutoCAD Civil 3D :: Two Alignments That Are Not Parallel

Oct 31, 2013

I have two alignments that are not parallel that make up one corridor.  Each alignment has a separate profile running along it.  At stations where I have a template drop in my section editor, it is not representing what is really happening because it just is perpendicular to one alignment.  Is there a way to develop a secondary alignment that will have my section editor show what will be parallel to both alignments.

View 1 Replies View Related

AutoCAD Civil 3D :: Polygon Shape With Partial Fill Used In Linetype

May 23, 2013

I've made a shape (attached image) and am trying to find a way to use it for a linetype.  However, I'd like to have the left and right "blocks" filled (hatch or whatever) so that when used repeatetively in a linetype, the filled and open spaces will alternate.  I may change it to be only 2 blocks or 4 - haven't decided yet.

I've made linetypes with simple line shapes, but never one like this.

I have exported the 3 polygons through the Map Drafting ribbon --> Export and then brought it back into CAD.  This gave me 3 adjacent filled polygons (3 seperate objects) and I don't know how to show it as one shape entity, much less without the middle fill.

Is there another way I can accomplish this without the use of shapes?

Civil 3D 2012
Windows 7 Enterprise SP1
Dell Precision T3400
(Q9550 @ 2.83 GHz)
8GB RAM
Nvidia Quadro GTX 650 Ti BOOST

View 3 Replies View Related

AutoCAD Civil 3D :: Parallel Automatic Labels

Mar 28, 2008

As you see in the picture I have a subdivision that follows a curving road, and therefore all the lot lines also follow the road. This is unfortunate, as I have been creating label styles 1 by 1 for left, center, right, for every angle of line. Is there a way to get your label to go parallel with the line automatically?

What I am thinking of is with structures, there is that circular grip that rotates the structure, is there something similar to this with labels? or must i keep grinding away making the labels one by one in their separate degree intervals.

Right now I have 33 label styles.... and I am not even 1/4 of the way done.

View 7 Replies View Related

AutoCAD Civil 3D :: Merging Corridor Surfaces That Run Parallel To Each Other

Dec 11, 2012

How do I merge 2 corridor surfaces that are running parallel to each other. Due to this being an overlay project the CL will stay the same just raised 4.5" from existing CL and the existing cross slope varies which we are matching until you hit the sawcut. We are not ripping out or milling any apshalt, it is strictly an overlay of the exisitng with 4.5" of new asphalt. We are saw cutting 2' either side of theedge of paveement and matching in with proposed.  

 I have created a feature line over the existing cl then raised it the required height. the cl has been offset 10 both sides to create my left and right shoulder alignments,  I then created a left and right shoulder corridor assembly which has supplied 2 seperate surfaces. I now would like to merge the 2 surfaces using the raised cl feature line as a break line to create the final proposed surface. I would prefer not to have to create feature lines from my corridor and create a new surface because i would like to take asphalt and subgrade quantaties at the end with out having to hand calc but will if need be.

View 4 Replies View Related

AutoCAD Civil 3D :: Best Fit Alignment From Parallel Linear Sets

Sep 21, 2012

I am trying to create a best fit alignment from parallel linear sets of COGO points. When I run the command, about halfway through the data set the alignment suddenly curves out of away from the COGO points. I tried doing a best fit individually on each side, one side works fine, the other sets station zero about a quarter of the way into the points and runs it back toward the start, leaving out 3/4 of the points.

View 9 Replies View Related

AutoCAD Civil 3D :: How To Model Two Parallel Roads With A Median In Between

Aug 23, 2012

i have a question for the gurus. how do i accomplish modeling two parallel roads with a median in between? in other words, say a northbound (NB) and a parallel southbound (SB) roadway, with a grass median in between them. the both roads have crown, and then eventually slope down towards the median, and at one point they meet.

I am curious to know if say for NB and SB, i have an assembly with the lanes, then shoulder, and then median area past the shoulder at x%, what subassembly should i use to accurately model the point where the NB and SB x%s meet?

*Edit:

I am not sure if i would be able to do it with only one baseline, as the roads may not always be parallel.

View 1 Replies View Related

AutoCAD Civil 3D :: How To Add Pressure Pipes

Apr 17, 2013

I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.

Do I need to create the flanges seperately and then add them to the end of pipes?

I'm using Civil 3D 2013

View 1 Replies View Related

AutoCAD Civil 3D :: Inner Diameter Of Pipes In SSA

Sep 30, 2013

I am modelling a sewer pipe network in SSA. At some stages we use varies pipe materials with different wall thicknesses. So I want to know how can I assign inner diameter of pipes in SSA so I just deduct wall thickness from pipe diameter and then assign it to the pipe. Or is there any possibility to make a pipe list with specific properties like part builder in civil3d?

View 5 Replies View Related

AutoCAD Civil 3D :: Breaking Pipes?

Nov 4, 2013

Is there any way to split a pipe (in a non-pressure network) in two?

View 2 Replies View Related