AutoCAD Civil 3D :: 2012 Pipes Don't Displaying In Profile / Works Correctly On 2 Computers
Mar 23, 2012
We are currently using 2012 Civil 3D, and we have a issue with a drawing that not all the Pipes from the pipe network are displaying in the Profile, and even the pipe properties display box the lengths show up way too long and the stationing does not display correctly in this pipe properties box either.
The Big Twist is that we have 2 machines in the offices that will display the drawing correctly, in profile view and pipe properties display box has correct lengths and stationing. So we know it is not styles, etc.
Direct support has suggested we un-install all Autodesk products and reinstall them all again, we tried the repair, however this did not work. Any other way before we have to go through all this work, as we are looking a huge amount of downtime, and we do not think this is the issue. Perhaps a Civil 3D variable or Autocad variable is different?
View 6 Replies
ADVERTISEMENT
Aug 30, 2012
We've just started using ACA 2012 and have noticed when importing files created in ACA 2009 that structural members do not display properly. We use the structural column or beam to represent a rainwater or soil pipe and are expecting to see a cut through at the cut plane and nothing else however we are getting a couple of lines that represent the crank in the pipe and I cannot turn them off. I'm sure that a setting has been introduced somewhere however after two weeks of looking I am still in the dark.
I've attached a file created in ACA 2009 that displays the problem in ACA 2012
View 7 Replies
View Related
May 24, 2011
When I use select object, it never displays the marquee correctly. One of two things will happen.
It will
1. Not even display the marquee at all e.g. I use select object by rectangular selection and the rectangle marquee box is invisible (although I can still select things)
or
2. If the marquee does display it shows it behind the objects, instead of in front of them, as scene in the image below.
View 2 Replies
View Related
Apr 21, 2013
why when i mesure the pipe diam prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok
View 8 Replies
View Related
Mar 12, 2012
I have two pipe networks and two profile views, one for storm and another for sanitary. I would like to show the crossing pipes on each of the profile views. When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display). Isn't there a way to display the styles for pipes different in each profile view?
C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM
View 3 Replies
View Related
Jun 22, 2009
I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.
View 5 Replies
View Related
Sep 17, 2013
How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.
View 9 Replies
View Related
Apr 5, 2013
Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view? see the screen shot of sketch of what I'm referring to.
View 2 Replies
View Related
Oct 16, 2012
What is the easiest way to correct contour lines when they don't display correct? Adding points, deleting points, switching edges...
See everything circled in orange on attached pdf.
View 5 Replies
View Related
Oct 23, 2012
I have run the interference check on pipes in my pipe network but I am not sure the results are accurate. I have set the 3D proximity distance to 1.7' in the attached example and Civil 3D found the pipes in interference with each other, but I'm not sure how this distance is calculated. This distance doesn't appear to be the pipe clearance measured along the perimeter (2.4' in green) or the inside diameter perimeter (1.8' in green) of my structure.
The distances measured directly between the pipes on the inside of the structure doesn't match the interference results either. I have set the pipe elevations and slopes to the same numbers in this example so I can measure the distance in 2D.
View 1 Replies
View Related
May 15, 2012
In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile. I have that profile style set to not plot so this way I can leave it on all the time. This is all fine and well. I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something. How do I add an addition data band label to achieve this? Everything I have found only lets me have these labels at a specified increment set in the band style.
View 2 Replies
View Related
Feb 28, 2013
Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.
Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.
View 2 Replies
View Related
Apr 19, 2013
I've got a weird problem with pipes in 2014. When I edit a pipe (right-click Pipe Properties) and make a change, when I press OK or Apply, the pipe SIZE changes? It's still listed as a 300mm PVC, but it's being represented as a 410mm? Look at the attached image. The storm (green) shoes a 300mm pipe and 375. The 375 is smaller? The pipe style (as you can see int he image, is set to display the inside pipe walls.
Nothing is unique here about the pipe sizes, this is a stock pipe catalog. But the size doesn't really change, only how the pipe is drawn in the profile. I've never seen something like this before. It measures .418m instead of .3m.
View 3 Replies
View Related
Sep 6, 2013
I have a water and sewer line that run parallel for the most part. The sewer starts at 10+00 runs west and then turns north about 10+80 and parallels the waterline from that point on.
I want to show the sewer in the water profile as beyond and to reference the sheets to see for P&P information. This works fine.
When i go to show the waterline in the sewer profile it does not show up correctly it only shows up in the initial 80 feet of the sewer profile. Is this because the two alignments are not parallel with each other until that 2nd manhole?
See attached profile PDF.
View 8 Replies
View Related
Mar 2, 2012
I have a utilities file with existing water and FM as shown in picture 1. But when I reference it into my sheet, the text becomes very tiny. Is there a setting for paper space I should change? The dash is correct, just the letters get small, so changing the ltscale in the original drawing blows up the dash also so that won't work.
Windows 7 x 64
Nvidia GeForce GTS 450
8 GB Ram
Intel Core i5-2310 @ 2.90 GHz
v. F.107.0.0 AutoCAD Civil 3D 2012 SP1
View 3 Replies
View Related
Apr 18, 2012
I am running a corridor in Civil 3D 2012 that has two baselines. Issues with multiple baselines in section views, but understand this problem was eliminated in 2012? In any case, this does not seem to by my issue. Attached you will find a section view through the two baselines (one is for a general overlay, the second for widening). The section view seems to display correctly at station 3+75, but 25' feet further down the road it does not display the corridor assemblies correctly (as can be seen by the lack of a ditch and shoulder overlay in the second image).
I have checked the code styles to make sure all links are included, as well as the comparing section view properties. All settings and styles appear to be the same, and the corridor seems to be built correctly. If I sample the Finished Grade corridor surface, it displays in section view as if the ditch were there (see third image).
Civil 3D 2010 & 2012
HP Z400 Workstation
Intel(R) Xeon(R) CPU W3550 @ 3.07 GHz
6GB of RAM
64-bit OS
NVIDIA Quadro 2000 running driver version 8.17.12.7105
Win 7 Professional
View 2 Replies
View Related
Dec 5, 2012
When pushing F1 for help in 2012 Civil 3D regarding this feature, it takes me to a page about migrating custom files over.
It says to copy the pipe/structure files over, then to open up Civil 3D and type in PIPECATALOGREGEN. Well, it doesn't work and says that it is an unknown command.
View 1 Replies
View Related
Apr 30, 2013
How I have come to this question is through the process of trying to realistically show a hydrant in profile view. First off it it possible to create a completely vertical pipe in C3D? Also if you can, is it possible to show that in profile view? Basically, what I am trying to avoid is representing a fire hydrant pipe by creating some sort of custom cyclinder part in partbuilder. I have done this, but do not like the results.
Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
View 3 Replies
View Related
Sep 17, 2013
I have drawn in essentially a sewer pressure pipe (using gravity part network because I don't have time to setup the other) and I am using PVC pipe and null structures at the joints. I created the pipe network from a feature line with verticies at the grade breaks and every 10'. As you can see in the picture the pipes are lining up but I have these straggling lines on the profile.
View 2 Replies
View Related
Jun 6, 2011
Requirement is to display pipes in profile with the same linetype ON TOP as shown in plan view, but bottom line of pipe must be continuous linetype.
Same problem as described here, 5 years ago [URL].......
I still do not see a way to control top and bottom pipe linetypes independently - using 2011.
View 3 Replies
View Related
Apr 20, 2011
Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.
View 4 Replies
View Related
May 31, 2007
I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.
Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?
View 5 Replies
View Related
Dec 5, 2012
I have pipe crossings shown in my profile. Only crossings (NO PROJECTIONS). So many elipises. I want to label them. Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation). I have accepted this (although it sucks).
Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label. Label type is "Entire Network Profile". When I do this, it labels not only the crossings but all projections. So I have a million labels chilling out in space, where I have no crossing.
View 1 Replies
View Related
Jan 10, 2013
So I have been getting a fatal error "INTERNAL ERROR: !dbobji.cpp@8743: eNotOpenForWrite" when I try to export to 2010 CAD.
I have worked out that it happens when pipes are displayed in the profile view.
View 7 Replies
View Related
Feb 12, 2013
Run profile on a self-intersecting street? The one I'm dealing with is a dead end 'P' shape. Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view. Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.
View 1 Replies
View Related
Oct 8, 2013
My colleague added parallel pipe networks and crossings to multiple SD profile views yesterday. Today, he came in, turned on AutoCAD, opened the drawing, and the parallel pipes and crossings were gone. The working folder had reset itself to nowhere so we reset the working folder and Data Shortcuts Folder, but that didn't bring them back. We can go into the profile view properties<pipe networks tab and turn the pipes and structures back on and override the styles, but that is basically redoing everything we did yesterday. Is there a way to avoid having to redo everything? Is there a way to avoid this from happening in the first place?
C3D 2013
Windows7 64 bit
View 3 Replies
View Related
Apr 12, 2012
I'm trying to attach a daylight subassembly that follows my DOT chart below. Is there one that does all of this or do I need to use a condtionalcutorfill and "something else" to do it? If the case, what subassembly would I use for the "something else"? If it's cut, the table below also determines the backslope... forming a ditch. How is the clear zone factored in? I need it to go the the flowline of the ditch when it's in cut. I have a design speed of 40mph, ADT of 7000+.
View 1 Replies
View Related
Aug 15, 2012
What do I draw the existing pipes as that will be under the surface that I'm profiling? I have the surveyed invert points I'm assuming that won't be polylines? how to get the pipe to show at the proper elevation on the profile?
View 2 Replies
View Related
Apr 30, 2013
I have a 2013 Civil 3D file, in which I've generated a set of multiple profile views, using a proposed centerline of a new pipeline as the alignment, and the existing grade surface. The profile views are just fine. However, there is also an existing underground electric service running roughly parallel to this proposed pipeline.
All I have to work with is a 3D polyline which shows the location and elevation of that electrical service line. Here's my issue: Right now the profile view(s) display on only the existing grade along the pipeline alignment, and that's fine. I would also like these profile views to display the location of the above described electrical line, but don't know how to get the profile view(s) to "see" it.
View 3 Replies
View Related
Apr 11, 2013
I've drawn a profile and would like to show the elevations of each surface selected in different bands. I've set up the bands easily enough though when they display on the section I've got two levels either side of the chainage line one with 0.01 precision and one with 0.001 precision - I only want to display one. I've tried fiddling with the Profile View Properties but don't seem to be getting very far..
View 3 Replies
View Related
Dec 31, 2012
I either have bad settings or have found a bug in 2012 when plotting parcels.
I have a P-drain Parcel setting for major drainage areas - I set the display to the C-PROP-BNDY layer which seems to be OOB for the entire 'property'. I create the parcels from poly lines on the P-DRAIN-AREA layer.
The parcels go to the C-PROP layer. My problem is that I can't seem to get the property lines to plot. I try to set C-PROP-BNDY to the correct color, yet when I plot, the lines don't show.
View 1 Replies