Revit :: How To Restrict A Length Parameter To 6 Inch Increments

Dec 14, 2013

How to restrict a length parameter to 6 inch increments using a formula?  Or another method?  I have a simple frame I want to stretch dynamically in 6 inch intervals.

View 4 Replies


ADVERTISEMENT

AutoCAD Inventor :: Change Length Of Geometry By Text Parameter?

Mar 15, 2013

I need to change the length of geometry by a text parameter.How to do this?

I tried this:

If widthselection="420" Then
Parameter(d11)=725mm
Parameter(width)=420mm
ElseIf widthselection="620" Then
Parameter(d11)=1075mm
Parameter(width)=620mm

[code]....

View 2 Replies View Related

AutoCAD Civil 3D :: Change 8-inch Pipes To 6-inch Without Having To Recreate Network

Dec 3, 2012

I have created a pressure network using 8-inch diameter pipes.  How would I change the 8-inch pipes to 6-inch pipes without having to recreate the network.

View 7 Replies View Related

Revit :: How To Round Dimensions In The Schedule To Nearest Inch

Aug 15, 2011

I'm trying to create an accurate door schedule.  I have curtain wall doors but on the schedule it rounds them to 1/16" How can I round the dimensions in the schedule to the nearest inch instead?

View 3 Replies View Related

AutoCAD 2010 :: Rescale Symbols On Drawing From 2 Inch To 1 Inch?

Apr 5, 2012

how to rescale the symbols on a drawing from 2 inch to 1 inch? For some reason I forgot this and now I am with my icons twice pick.

View 9 Replies View Related

Illustrator :: Small 1 Inch By 1 Inch Logo For Invoices - Resolution Of 600 DPI

Jan 25, 2013

Someone would like a small 1 inch by 1 inch logo for invoices at 600 DPI. However I understand that illustrator doesnt work in DPI or PPI since it's vector. Would I have to transfer the small image over to photoshop. I did try and save a 1 inch by 1 inch logo at 600 PPI, however when I saved the image it was no longer 1 inch by 1 inch. It had increased significantly in size regardless of what file format I saved the image as.

View 10 Replies View Related

Revit :: Select Placed Joist And Change Spacing From 12 Inch OC To 16 Inches OC?

Mar 5, 2014

I placed I-Joist on the floor plan and used the wrong spacing. Can I select the already placed joist and change the spacing from 12 inch OC to 16 inches OC? I know I can select the ones I want to change, but I do not see in the properties window where I can change the spacing. Unless I am overlooking it.

View 9 Replies View Related

3ds Max Animation :: Wire Length Parameter Of Taper Object - Illegal Self-reference In Controller Script

Nov 28, 2011

I try to wire the length parameter of a taper object to the local Y-Position values of another object. It works fine until I reload the file. I get an MAXScript Wire Controller Exception error:

--Runtime error: Illegal self-reference in controller script

...and the parameter-wire dialog opens. The desired functionality returns by clicking the Update Button and everything works fine again.

View 1 Replies View Related

AutoCAD Inventor :: Drive IPart LENGTH Param By IAssembly Table Custom Parameter Column?

Feb 21, 2012

In a simple case I have an extrusion with some attached seals/weather stripping, all implemented as iParts having their own LENGTH parameters.

RailPart.ipt, Seal_A.ipt, Seal_B.ipt

The goal is to encapsulate these IParts within an iAssembly: RailAssy.iam, where a LENGTH parameter can be input when the iAssembly is placed, causing RailPart and Seal_A to have their length parameters set to the LENGTH provided at that time and SEAL_B having Length set by an iLogic rule to LENGTH - 5.

I've been unable to set up a Custom Parameter Column in an iAssembly table.  Is this even permitted? 

Inventor Premium 2012 SP1

View 5 Replies View Related

Illustrator :: One Inch Square Box Does Not Draw One Inch

Oct 7, 2013

If I try to draw a square box in any size, illustator does not make it square.
 
For example, if I select the Rectangle Tool, click in the art space and set the rectangle to one inch by one inch, I get a box that is 1.0003 by 1.0003
 
Here is a screen shot of what I am getting.
 
This is also happening to any rectangle and circle.
 
Even if I hold down shift to keep the preportions lock, it still happens.
 
I have check and nothing is snapping or set to snap.
 
This is a major issue for me as I use illustator for creating dielines and those dielines need to be very accurate.

View 8 Replies View Related

Revit :: How To Set Parameter Up

Mar 22, 2013

I have been working on creating windows for the place I work.  I want to make my windows so they are quick and easy to create new ones without having to add in new information like if the glass is tempered or if its an egress window. I would like to set up formulas for these.  I am stuck at my egress window parameter.  I have included an image of what I am working on and the calculations and formulas I have so far.  I would like to have my egress check box to say yes if the Opening Width is greater then 20", the opening height is greater then 24" and the opening sf is greater then 5.7 Sf.  How would I set this parameter up?

View 3 Replies View Related

Revit :: Sorting By A New Parameter

Oct 20, 2013

I've created an area schedule that divides my plan into seperate appartments. I would like to sort mu window schedule by this parameter- is there an option to link a window to a specific area, just like it's linked to floors?

View 1 Replies View Related

Revit :: Change Parameter Values In The Tag

Mar 5, 2014

How I can get the finished floor material from the floor in the room tag? The only way I know is to manually write material via Change Parameter Values in the tag.

View 2 Replies View Related

Revit :: Create New Parameter On Sheet

Jun 4, 2013

I am able to get the parameter to appear on the project information tab, but I cannot get the information to appear on the sheet.  I would like to create a phase parameter on the sheet so that different projects under the same building will be specific to the project and not just the building.  

View 1 Replies View Related

Revit :: Create A Parameter With The Filename?

Jul 30, 2012

It is possible to create a Parameter with the Filename? I have only found the FilePath parameter... 

View 2 Replies View Related

Revit :: Tooltip On Label Parameter?

Oct 5, 2011

Does the tooltips on Label Parameters can be modified? I would like to customize the tooltips on label parameters, which currently default to "Edit Parameter"...lame-oh; that tells the user very little. Perhaps the developers could add a customize tooltip control in the Edit Label dialogue box. Can the tooltips be accessed through the database?

View 2 Replies View Related

Revit :: Parameter Group Not Sticking?

Feb 19, 2014

I have set 2 parameters in the Family Editor so they 'Group Under' Dimensions, yet when I load into a project (that the family object has been deleted out of via the Project Browser), I find instead they are Grouped under 'Other'.
 
One of the offending objects attached.
 
I've done this 2 ways, once by opening within Revit the Family Editor, making the change and then loading back into the file, only to find nothing has changed, and also then by again opening up in the family editor from Revit to find ditto; and separately by opening up the file directly in Explorer and then loading into the open project.
 
Not an enormous problem, just annoying as I want to group Dimensions parameters naturally enough under Dimensions!

View 3 Replies View Related

Revit :: Rounding Up Length Parameters?

Oct 16, 2012

I am making a Schedules for metal flashings that i have added to my project. I have not had any problems using shared parameters to get the length of my line based families and everything is working fine.

But now comes the tricky part. I need to somehow add a parameter that would roundup my real lengths to my production lengths. f.eks i have couple flashings that are 2569mm And what i would like the schedule to show is that I have couple of 3000mm flashings.

View 3 Replies View Related

Revit :: Correct IFC Exports Using Visibility Parameter

Mar 4, 2012

I find the visibility parameter a very useful option when building families. Unfortunately it doesn't work when exporting IFC. The elements set to not visible are visible in the IFC exports.
 
I also experienced IFC export issues with the use of phases.An element created at phase 1 and set to demolished at phase 2, will not be visible in the IFC export of phase 1.
 
The IFC Exporter for Revit 2012 v1.0.4.msi was used when running into these issues.How to be able to have correct IFC exports using the visibility parameter ?

View 4 Replies View Related

Revit :: Create Text Parameter For Windows

Jun 12, 2013

I am using Revit 2013 and I am trying to create a text parameter for my windows that will tell you what grid is installed in the window according to which grids you choose (from my parameters above) I have included a picture to better show what I am trying to do.  So far the parameters i have tried to use don't seem to work.

View 2 Replies View Related

Revit :: Possible Convert Numeric Parameter To Text

Jul 26, 2012

Is it possible to convert a numeric parameter to text so i can add it to another text feild? I cant seem to find a way to do it.

View 2 Replies View Related

Revit :: View Specific Parameter For Cut Plane

Feb 23, 2014

when I insert a window family the cut plane Revit uses is that of the family rather than that of the view. This causes a lot of problems for us when we need to cut the same window at different levels in different views and the window itself should look different. The window itself is built to look differnet at 3 ranges of cut plane height. However, if I try to control this throught yes/no visibility parameter it affects all views. I fail to make it view specific. Is there any way to make an instance parameter or view specific parameter for the cut plane/ visibility of parts in the window family. It is such a basic need for architects and I fail to understand its absence in the Revit. Generaly speaking one should be able to control what you see in each plan section view. It's an essential thing in architectural drawing.

View 9 Replies View Related

Revit :: Modify Parameter Values Without Opening

Feb 16, 2012

I wonder if we can play with a revit family file ; for example modify parameter values without opening revit.

View 2 Replies View Related

Revit :: New Project Parameter To Reference A Data Set?

Dec 30, 2011

How do I set up a Project Parameter to reference a txt file as a data set?  (the same way CSI division codes are referenced)

View 4 Replies View Related

Revit :: Constrain Family And Rotate With Parameter?

Jul 15, 2013

I need to constrain a handle to a butterfly valve and add a parameter for rotating the handle angle.  I can't achieve this as when I constrain the handle to the valve the handle will not rotate without breaking the positional constraints.
 
I've tried looking at the door swing posts but they don't use circular objects and I can't get them to work for my valve.

View 1 Replies View Related

Revit :: Families - Lock Parameter Value Across All Types

Apr 24, 2012

I have a family that has over thirty types and I need to update a single parameter value across all types to be the same value.  Is there a global way to perform this task instead of the current copy/paste/paste/paste method I am doing.  I thought about exporting to a catalog and modifying the text file in Excel, but I lose my formula when I do that.
 
If this isn't possible, this would be a good wishlist item, Autodesk - where a family has global parameters that are consistent throughout the family, regardless of type.

View 7 Replies View Related

Revit :: Make Conditional Formulas With A Parameter?

Mar 5, 2012

I was wondering if there was a way to make conditional formulas with a parameter?  So I want a parameter called system.  On the pulldown to enter the field under properties.
 
 I want there to be 3 choices (i.e. 1=Air, 2=Water, 3=Gas). 
 
If the user tries to enter any value other than the 3 values specified (whether by typing or pulldown), a message comes up stating they cant do that.  The names for the systems have been simplifed for this example but the spelling is critical to the external database.  I have tried but  but I keep getting the follwoing is not a valid family parameter: X. X because thats the first conditional value. 

View 4 Replies View Related

Revit :: Prevent Empty Parameter From Showing As (?) In Tag?

Dec 30, 2011

Is there a way to prevent an empty parameter from showing as a "?" in a tag?

Windows 7RAC2012

View 3 Replies View Related

Revit :: Filter Parameter Values ​​which Are Only Applicable?

Oct 22, 2013

I'm wondering if it is possible to filter/show only parameter values which are only applicable to that parameter. So no parameter values belonging to other parameters in a family. This to avoid that users are selecting wrong values. For example a door with several text parameters. See also the screendump.

View 1 Replies View Related

Revit :: Create New Parameter Under Identity Data

Feb 28, 2014

How to create a parameter field to include the MasterFormat data using 'txt' file similar to Assembly code parameter already built into revit families. I don't want to use the Keynote field for this purpose. I am looking for a ways to create a new parameter under the Identity Data.

View 1 Replies View Related

Revit :: Reporting Parameter For Stair Pitch

Jul 25, 2013

Is it possible to create a Stair Tag with the pitch reported?  I have a tag which includes the number and height of rises as well as the size of treads but I would like to include the pitch also.  Obviously this would use the dimensions of the rise and tread in the formula Tan X = Rise/Tread, but how do I create this in a tag?  I have looked at using a Reporting Parameter but every time I read the Wikihelp paragraph on them my eyes just glaze over as I cannot follow it at all but it does mention formulas....

View 8 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved