Revit :: Prevent Empty Parameter From Showing As (?) In Tag?
Dec 30, 2011Is there a way to prevent an empty parameter from showing as a "?" in a tag?
Windows 7RAC2012
Is there a way to prevent an empty parameter from showing as a "?" in a tag?
Windows 7RAC2012
Every-time I synchronizing a folder, Lightroom always shows Previous Import for the found images.I think this is very annoying, since I manually have to point to the synchronized folder.When I synchronize a specific folder I expect Lightroom to stay on that specific synchronized folder!There should at least be an option for this in the preferences but I haven't found anything...
I'm currently following a longer Lightroom 5 course on Lynda and this don't occur on the authors mac when synchronizing occurs!Is this a windows-only issue or should I dig deeper into my manual?
I have a drawing that is shwing model space empty, nothing in it, however on paper space the drawing is there. I can double click my viewport and able to use my drawing commands as normal. what has happened how come i cant see my drawing in model space, like it is hidden, i have tried regen, redraw etc.
View 6 Replies View RelatedI want to show text on selected individual slides in a slideshow . I know that I can use caption or title for this ( can I use either one or is there a preferred one ? ) .
However , not all the photos in the slideshow have captions, so for those without, it shows " < empty >" respectively 2 " ". I want that there is nothing on the slide if there is no caption. How can I do this
How do I prevent the components beyond the non-transparent walls and roof from showing through. I have double and triple checked the the transparency setting for the walls and roof in 'Override Graphics in View' and they are both set at '0'. Note these specifics:
Walls: Only the window glass shows through.Concrete Roof: Everything shows through as if transparency is set at 50%.
In 2013, I had an optional part parameter for pipes called "Velocity", and it worked fine. We use a network catalog, and I was trying to use the same part catalog for 2014, but it gave me a Runtime Part Parameter Configuration Error for the Parameter Name "VEL". So I copied the "Pipes Catalog" folder from my C drive for 2014 and pasted it to the network. I then revised the AeccPartParamCfg.xml in the AeccShared Content folder with the same information as I had in the previous network catalog.
Specifically, I added the following line in the xml file
"<AeccDfParameter name="VEL" desc="Velocity" context="FlowVelocity" index="0" datatype="Float" usage="Double_General" unit="" visible="True" internal="True"/>"
and further down in the xml file under
" <AeccParamUsage>
<AeccPartDomainCfg domain="Pipe_Domain">"
I added the line "<AeccOptParam context="FlowVelocity"/>"
see the attached image 1-Old AeccPartParamCfg xml file.JPG to see images from the xml file.
I got the same error when I opened C3D 2014. I added an underscore between Flow and Velocity for context, and it worked! (See attachment 2-Revised AeccPartParamCfg xml file.JPG)
So C3D 2014 opens without the error. I click on Part Builder and click on RCP (formerly Concrete Pipe from OOTB part catalog) under pipes. I right click on Size Parameters and click "Add..." which takes me to the New Parameter dialog box as seen in attachment 3.JPG. It shows three of the optional properties I have added: Pipe Classification, Friction Slope, and Velocity.
I add these three optional properties and edit their configurations as seen in attachment 3.JPG. I give Friction Slope and Velocity both a range of 0 to 1000 with a default of 0.
I create a new parts list and add the part family RCP. I click to add part sizes and get the final dialog box on attachment 3.JPG. Velocity doesn't show up! Pipe Classification and Friction Slope show up, but no velocity!
I have tried deleting the 'VEL" line in the xml file, copying the "FSL" line and pasting and revising it for velocity, but that didn't work. I tried switching the FSL and VEL lines in the xml file to see if FSL would disappear and VEL would appear, but that had no effect.
C3D 2014
Windows 7 64 bit
I have been successfully able (after reading through the Users Manual) to create a new door style and a new property set definition applied to that door style. I was able to insert the new door style in a drawing and the Extended Data tab on the Properties pallet on the right side of the screen showed all the propwer data, except for one field.
I used two parameters from the Project Properies Definitions in my "custom" property set but only one of them (Number) seems to be working as expected to contain my Project ID Number within my door style. The Division ID parameter, however, does not contain anything within my door style except "NA", even though I placed a value in the Division ID field in the Project Navigator Tool Pallet.
"NA" is what shows up in the field on the Extended Data portion of the Properties pallet for the selected door instance.
As an aside, I found writting this post to be very time consuming because I had to keep refering back to the various ACA screens and pallets to be sure of using the correct names for everything to avoid confusion. Hopefully I have succeeded!
I have been working on creating windows for the place I work. I want to make my windows so they are quick and easy to create new ones without having to add in new information like if the glass is tempered or if its an egress window. I would like to set up formulas for these. I am stuck at my egress window parameter. I have included an image of what I am working on and the calculations and formulas I have so far. I would like to have my egress check box to say yes if the Opening Width is greater then 20", the opening height is greater then 24" and the opening sf is greater then 5.7 Sf. How would I set this parameter up?
View 3 Replies View RelatedI've created an area schedule that divides my plan into seperate appartments. I would like to sort mu window schedule by this parameter- is there an option to link a window to a specific area, just like it's linked to floors?
View 1 Replies View RelatedHow I can get the finished floor material from the floor in the room tag? The only way I know is to manually write material via Change Parameter Values in the tag.
View 2 Replies View RelatedI am able to get the parameter to appear on the project information tab, but I cannot get the information to appear on the sheet. I would like to create a phase parameter on the sheet so that different projects under the same building will be specific to the project and not just the building.
View 1 Replies View RelatedIt is possible to create a Parameter with the Filename? I have only found the FilePath parameter...
View 2 Replies View RelatedDoes the tooltips on Label Parameters can be modified? I would like to customize the tooltips on label parameters, which currently default to "Edit Parameter"...lame-oh; that tells the user very little. Perhaps the developers could add a customize tooltip control in the Edit Label dialogue box. Can the tooltips be accessed through the database?
View 2 Replies View RelatedI have set 2 parameters in the Family Editor so they 'Group Under' Dimensions, yet when I load into a project (that the family object has been deleted out of via the Project Browser), I find instead they are Grouped under 'Other'.
One of the offending objects attached.
I've done this 2 ways, once by opening within Revit the Family Editor, making the change and then loading back into the file, only to find nothing has changed, and also then by again opening up in the family editor from Revit to find ditto; and separately by opening up the file directly in Explorer and then loading into the open project.
Not an enormous problem, just annoying as I want to group Dimensions parameters naturally enough under Dimensions!
I find the visibility parameter a very useful option when building families. Unfortunately it doesn't work when exporting IFC. The elements set to not visible are visible in the IFC exports.
I also experienced IFC export issues with the use of phases.An element created at phase 1 and set to demolished at phase 2, will not be visible in the IFC export of phase 1.
The IFC Exporter for Revit 2012 v1.0.4.msi was used when running into these issues.How to be able to have correct IFC exports using the visibility parameter ?
I am using Revit 2013 and I am trying to create a text parameter for my windows that will tell you what grid is installed in the window according to which grids you choose (from my parameters above) I have included a picture to better show what I am trying to do. So far the parameters i have tried to use don't seem to work.
View 2 Replies View RelatedIs it possible to convert a numeric parameter to text so i can add it to another text feild? I cant seem to find a way to do it.
View 2 Replies View Relatedwhen I insert a window family the cut plane Revit uses is that of the family rather than that of the view. This causes a lot of problems for us when we need to cut the same window at different levels in different views and the window itself should look different. The window itself is built to look differnet at 3 ranges of cut plane height. However, if I try to control this throught yes/no visibility parameter it affects all views. I fail to make it view specific. Is there any way to make an instance parameter or view specific parameter for the cut plane/ visibility of parts in the window family. It is such a basic need for architects and I fail to understand its absence in the Revit. Generaly speaking one should be able to control what you see in each plan section view. It's an essential thing in architectural drawing.
View 9 Replies View RelatedI wonder if we can play with a revit family file ; for example modify parameter values without opening revit.
View 2 Replies View RelatedHow do I set up a Project Parameter to reference a txt file as a data set? (the same way CSI division codes are referenced)
View 4 Replies View RelatedI need to constrain a handle to a butterfly valve and add a parameter for rotating the handle angle. I can't achieve this as when I constrain the handle to the valve the handle will not rotate without breaking the positional constraints.
I've tried looking at the door swing posts but they don't use circular objects and I can't get them to work for my valve.
I have a family that has over thirty types and I need to update a single parameter value across all types to be the same value. Is there a global way to perform this task instead of the current copy/paste/paste/paste method I am doing. I thought about exporting to a catalog and modifying the text file in Excel, but I lose my formula when I do that.
If this isn't possible, this would be a good wishlist item, Autodesk - where a family has global parameters that are consistent throughout the family, regardless of type.
I was wondering if there was a way to make conditional formulas with a parameter? So I want a parameter called system. On the pulldown to enter the field under properties.
I want there to be 3 choices (i.e. 1=Air, 2=Water, 3=Gas).
If the user tries to enter any value other than the 3 values specified (whether by typing or pulldown), a message comes up stating they cant do that. The names for the systems have been simplifed for this example but the spelling is critical to the external database. I have tried but but I keep getting the follwoing is not a valid family parameter: X. X because thats the first conditional value.
I'm wondering if it is possible to filter/show only parameter values which are only applicable to that parameter. So no parameter values belonging to other parameters in a family. This to avoid that users are selecting wrong values. For example a door with several text parameters. See also the screendump.
View 1 Replies View RelatedHow to create a parameter field to include the MasterFormat data using 'txt' file similar to Assembly code parameter already built into revit families. I don't want to use the Keynote field for this purpose. I am looking for a ways to create a new parameter under the Identity Data.
View 1 Replies View RelatedIs it possible to create a Stair Tag with the pitch reported? I have a tag which includes the number and height of rises as well as the size of treads but I would like to include the pitch also. Obviously this would use the dimensions of the rise and tread in the formula Tan X = Rise/Tread, but how do I create this in a tag? I have looked at using a Reporting Parameter but every time I read the Wikihelp paragraph on them my eyes just glaze over as I cannot follow it at all but it does mention formulas....
View 8 Replies View RelatedI would like to know that while system families are not editable, would the shared parameters file for these families be accessible? I am looking to add a custom label for sections.
View 1 Replies View RelatedI created a project parameter (in order to group my sheets with my custom system) and I'd like to create a label on my titleblock that's the ability to show this project parameter atomatically.
I reckon it has something to do with shared parameters but how to use them.
I need a parameter that will pull the reference level elevation. is this possible to accomplish in a structural foundation family?
View 3 Replies View RelatedI have a family, with three nested families: A, B and C.
Either A or B can be picked through a "Family Type" parameter. Family C is locked to a reference plane, which is defined by a dimensional parameter called "Offset." Is there a way to have the value of "Offset" change based on whether A or B is loaded? Not sure how to use the "Family Type" dorp-down parameter in/with a formula to do so.
When I flip a door from left to right side can I see changes in schedule table? I can't fin a parameter for swing orientation.
View 8 Replies View Related