AutoCAD .NET :: Can't Load Assembly
Mar 15, 2012
I have been trying to interface to AutoCAD from my VS 2010 project without luck.
My environment is 64bit windows 7 environment. I installed on my computer AutoCad 2012 and ObjectARX 2012.
I created a basic hello world project where I referenced the AcCui.dll AcDbMgd.dll AcMgd.dll but I keep getting errors when running it.
An unhandled exception of type 'System.IO.FileNotFoundException' occurred in Unknown Module.
Additional information: Could not load file or assembly 'Acmgd, Version=18.2.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified.
I have tried it with "Copy Local" false (also with true), I have tried to reference the dlls from the ObjectARX directories as well as the AutoCAD installation folders without luck.
View 5 Replies
ADVERTISEMENT
Dec 1, 2012
I was trying to figure out the best way of loading an external WPF executable assembly into Autocad. The scenario is simple though to explain.
The user enters a command in Autocad. The command invokes a WPF application, which loads a particular WPF Window. The command also need to pass a parameter to the WPF application when it requests the WPF Window to load. When the user is done with the Window, he closes it like any modal window that appear in Autocad. What are the possible ways to have such an interaction in AutoCAD using .Net and C# and WPF
View 5 Replies
View Related
Apr 19, 2011
I use VB.net in VS2010 design some drawings in AutoCad2011, in .NET 3.5.I write a Class Library in VS2010 to draw some blocks in Autocad, and it runs OK.
Then I design a Windows Forms Application in VS2010 for some inputs, and call my program above. However, everytime I got error as below in my Class Library code.File not found exception was unhandled,
Could not load file or assembly 'acdbmgd, Version=18.1.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified.
View 5 Replies
View Related
Sep 11, 2012
I want to create a silent acad process in background and do some works, it works well in AutoCAD 2012. But when I upgrade to AutoCAD 2013, it cannot works. I already had referenced accoremgd.dll. It compiles well, I get the errors "Could not load file or assembly 'accoremgd.dll' or one of its dependencies . The specified module could not be found." when I run my program. Who can tell me what dlls i lose to referenced.
View 9 Replies
View Related
Nov 23, 2011
Since Deep exploration is a sub-part of Corel X5, I turn to here first before barking at another tree.I use trial COREL Designer X5 with DE CCE 6.3.4 supplied. I reckon, even though the DE is supplied with Corel as a plugin. Corel should be the one customers should turn to before turning to RH.
Upon loading a SLDASM file fromSolidworks in DE, I get this "Component Load Error [DST03175-Fot] : File does not exist. (Error code -28) : C:SolidWorks_ArbetskatalogDST03175-Fot.sldprt"
The CCE used to work before, i.e loading the assembly, but now... it doesn't. There is nothing online about this error, there is no support information what so ever.
View 1 Replies
View Related
Jun 4, 2013
Is it possible to use a load statement in a profile to automatically load/unload a cuix?
View 7 Replies
View Related
Jun 6, 2012
I am using INV 2012 and I wan to to know a trick how to convert the weldment assembly back to regular assembly template.
View 1 Replies
View Related
Jul 10, 2012
I'm looking for the best way to create a separate assembly out of various component parts in an existing assembly so that the whole thing can be placed in an assembly as you would a part, I know it's possible to demote components within an assembly but are there any other methods similar / better ?
View 2 Replies
View Related
Sep 18, 2012
We have an iLogic assembly with to parts in it. Maybe to cylindrical parts. The iLogic rules should do the following.
1. Start a Rule after open document.
2. This Rule starts a Rule in the first cylindrical component.
3. This Rule ask the user for a diameter.
4. The assembly gives this new parameter value to the second component
5. Then the assembly calls another rule in the second component to change it with the new parameter
Everything is working fine when the following combinations are taking place:
1. I open up the assembly out of vault or from a local drive or an accessible server drive
2. I insert the assembly as sub assembly in another assembly from a local drive or an accessible server drive
It don't work with the following situation:
- I insert the assembly as sub assembly in another assembly out of vault
Then the user becomes the dialog "Choose a diameter" twice.
I don't know why, but I have the idea it has something to do with the functionality of inventor to insert a component more than once. If you insert a component in an assembly Inventor gives you the opportunity to add more than one occurence after each other.
change that behaviour? Maybe a switch to change that inventor "add more than one occurence" behaviour.
View 1 Replies
View Related
Feb 9, 2012
I have encountered a problem with the Tube and Pipe styles.
As you can see, I have a rack assembly with a custom tube and pipe style. A wire as a tube in orange, and a tube support in white. Both have their seperate colorations at a style in the tube and pipe styles editor
When placing the rack assembly into the main assembly, it reverts to the coppor coloration I changed from the original style.
Steps I've taken:
Exported the styles .xml and Imported the styles into the master tubeandpipe.iam
Imported the user created .xml styles into the main assembly file nothing seems to work
View 8 Replies
View Related
Apr 23, 2012
I am trying to find the interior volume of an assembly (when am I not?!?!) by subtracting the assembly from a block that surrounds the most of it. Somewhere the assembly has a "leak" and I have been trying to use the Cross Section Analysis to track down where the inside lump is connected to the outside lump to be subtracted. Is there a less time consuming way to dynamically drag a plane across and get cross sectional views?
Even better is there a simple way to animate the analysis plane moving across the block so I can hopefully just watch and pause it when I find a leak?
Inventor 2013 (SP2 Update 2), Windows 7 Professional (64-bit), SP1, Intel Xeon 3.07GHz CPU, 12GB RAM, NVIDIA Quadro 2000, Vault Basic 2013
View 2 Replies
View Related
Oct 30, 2012
it is possible to make a constraint that utilized a parameter of a part within the assembly.
For example, if I wanted to use the thickness of a plate, which I defined in the part, could I call that parameter in a constraint?
View 1 Replies
View Related
Oct 31, 2011
My assembly has grown (about 50 parts) to where I need to consolodate some parts into subassemblies for reuse and alternate iterations of the basic design.
When I import the original parts into a new assembly, all of the constrains I created are not there of course.
I've tried creating a new empty part and then deriving a new part from the assembly, but I can't add, delete or edit any parts.
I looked at using Shrinkwrap, Substitutes, iParts, Multi-body Parts, and Multiple Solids but I remain confused.
In retrospect, maybe I should have created the subassemblies between the part and assembly stage but I didn't.
View 4 Replies
View Related
Jul 11, 2013
I thought I created a rail sub assembly.
So I created the rail sub assembly everything looks great in sub assembly composer.
Start a new dwg data reference in the rail alignment, Note the rail alignment type is set to rail.
Create an assembly and under the Construction tab for the assembly the Assembly Type is set to Railway. Attach my custom sub assembly to this assembly.
Created a corridor and I get this error: Something wrong with current subassembly: Operation is not valid due to the current state of the object.
So I delete my sub assembly attach the Civil 3D Rail Single sub assembly. Re run corridor and everything works fine.
So I promote the alignment change type to centerline. Delete the Rail Single sub assembly put my rail sub assembly back. Rerun the corridor and everything works.
So then I undo everything up to the point of promoting the alignment.
Opened the base file changed the alignment type to centerline.
When I tried to synchronize the references I ended up a broken reference with the following error. Invalid reference. Synchronization failed
Not good we already have plan sheets cut.
where in sub assembly composer were do I define the sub assembly to be for Rail?
View 2 Replies
View Related
Nov 9, 2011
I want to be able to control the location/position of a component in an assembly. This is easy enough through the iProperties/Occurrence tab and then adjust the location of the X,Y, and Z offsets. Is this possible using iLogic? I have been unable to find a function to access via iLogic. Ultimately I am trying to translate a component about an axis not a pattern.
View 1 Replies
View Related
Nov 28, 2011
Can I select a bunch of parts in an assembly and say "save these pieces as a new assembly"?
It is just such a needed tool but I cant find an easy way to accomplish this.
View 2 Replies
View Related
Oct 3, 2013
I have a two part duct fire damper assembly. The IDW has the combined two part assembly, which I know how to turn the CoG on, so that it can be dimensioned. The problem is each piece will more than likely be hoisted separately so I would like to show the CoG for each piece, not the combined master assy.is there a way to do this?
Inventor 2014
Windows 7 Pro SP1
Intel(R) Core(TM) i7-3770k CPU @ 3.50GHz
16GB RAM
NVIDIA Quadro 4000
3D Connexion SpaceMouse Pro
View 5 Replies
View Related
Sep 3, 2013
I would like to see if there is a routine that allows my iLogic code to detect if my assembly contains another assembly within it. If my assebly contains assemblies then I don't want "MyRule" to run. Else if it does then I want "MyRule" to run.
View 4 Replies
View Related
Jul 19, 2013
I have a finished corridor, but now I need to add marked points to label a few key grade breaks in my cross sections. When I attempt to add the marked points on some of my sub-assemblies it gives me the error that the sub-assembly is not part of the assembly. I can right click the sub-assemly and choose "Add to Assembly" but when I rebuild the corridor it strips all the sub-assembly data from my assembly and leaves me with essentially a null assembly for the range.
View 4 Replies
View Related
Mar 21, 2013
My Assembly has two possible positions for my piston.
I would like to show both piston positions (top and bottom) in one drawing file; however, in different drawing views.
I have tried using LOD and Drawing View Representations, but it is my understanding that neither of these are meant to be used in this way.
View 2 Replies
View Related
Dec 24, 2010
I have a project that suddenly won't load. I have 25 versions of it, I save it under a new file name each time in case I need to go back to an older version.
Trouble is most of the versions won't load! Only the very early versions will load. Some of the later version start to load then disappear.
Hardware hasn't changed on the PC, maybe the video drivers have been updated, thats about it.
View 2 Replies
View Related
May 23, 2012
How to automatically run dvb file when acad starts, I have been trying in autocad but its not working.I am using ACAD 2007
View 7 Replies
View Related
Apr 6, 2012
To my knowledge this file has not been renamed and definitely not been deleted...Has been moved, but does that matter? The attached image is the error i get when trying to load .cuix as a partial in CUI dialogue box. I cannot load from CUILOAD, either.
I have verified that another cui of the same name is not already loaded.
View 3 Replies
View Related
Jun 15, 2012
I've got a firm of about 60 architects and we use a custom dll that loads on drawing open. the dll loads fine on all but one computer. even explicitly issuing the netload command and grabbing the dll manually does not work. it also does not work on other profiles on that computer (i tried an admin profile, even though the user is a local admin).
we're using .NET 4.0 on ACAD 2011
View 9 Replies
View Related
Jan 6, 2014
I have a project in my PC, and build it to file ".dll". It is working fine in my machine with "netload" command (to load it).
But in another PC "Netload" command can not load it . How i can load Dll file on other PC?
View 6 Replies
View Related
Oct 10, 2006
I tried applying this flag to one of my commands for Autocad 2006. The documentation states that it forces users to enter the full namespace of the command in order to invoke it.
The problem is that even after defining the local, global, and group names I can't get the command to load. I've tried every possible namespace I could think of when entering the command into Autocad. The command works if I do not apply the flag, and typing GroupName.GlobalName into the command line also works - unless I add the Undefined flag.
[CommandMethod("group1", "cmd1", CommandFlags.Undefined)] _
Public Sub Test()
End Sub
View 3 Replies
View Related
Dec 26, 2012
I'm having trouble with my command not loading via a netload in AutoCAD 2012 SP1 64bit running on Windows 7 64bit. It works on most of my user's computers, but on a couple of the computers it doesn't seem to be doing anything. I'm using Visual Studio 2010 for coding and debugging, but I don't have debugging software on the computer that is causing the problem. I've attached my commands class in it's entirety to this post. The dll resides local on the user's computer and is not in a network location. When I run the netload on the development machine or one of my other working users, I get the message boxes and the program seems to run fine, but on the computers that aren't working I get nothing. No errors, no message boxes, nothing.
View 9 Replies
View Related
Aug 15, 2011
I was wondering if there was any way to control what gets loaded - almost like a "Safe Mode" with only basic functionality.
View 2 Replies
View Related
Feb 29, 2012
I have a .dll that uses registry entries to load itself when AutoCAD starts. But I have encountered a problem where it also loads even
When a customer chooses to load another AutoCAD plugin by another vendor. I would like it ideally only to be loaded when the user clicks on my desktop shortcut.
I am writing in VB.net & have noticed some vendors use a reference to object.arx in their shortcut. Is it possible to do this with a vb.net .dll or even a lisp?
View 3 Replies
View Related
Dec 8, 2012
I have been using the ribbon api to create my custom ribbon. I am now attempting to load said rribbon at startup by placing the load command into the initialize componant. It isn't working.
Dim ribCntrl As Autodesk.Windows.RibbonControl = Autodesk.Windows.ComponentManager.Ribbon
If ComponentManager.Ribbon Is Nothing Then
Return
End If
For i As Integer = 0 To ribCntrl.Tabs.Count - 1
[code]...
I seem to remember being told it's because the ribbon .dll hasn't yet started at this point sso it has nothing to use to load it?
View 3 Replies
View Related
May 10, 2011
I am using VB.NET 2010 Express, and have created a dll that only appears to load correctly when launching the debugger. When I use netload to load my dll I get an error stating:
"Cannot load assembly. Error details: System.IO.FileLoadException: Could not load file or assembly...
...System.NotSupportedException: An attempt was made to load an assembly from a network location which would have caused the assembly to be sandboxed in previous versions of the .NET Framework..."
The error pops even if I move the dll to the local acad support folder. I have already changed the target framework to ".NET Framework 4" since I am modifying this from a file that loaded correctly in 2011 with 3.5.
View 2 Replies
View Related