AutoCAD 2010 :: Lost Block Property Table Window?
Apr 26, 2012
I am having some troubles whit my dynamic blocks.
Whenever I add a block property table the window that should be opent doesn't open. The strange thing is that I think it actualy is open but i just don't see it on my screen. The same thing gous for the screen that allows you to ad a parameter to a lookup set. by folowing this link you can see what i mean, it gets interesting after 30 seconds.
[URL]
Is there a variable that decides where on your screen you see these screens?
View 2 Replies
ADVERTISEMENT
Apr 26, 2012
I am having some troubles whit my dynamic blocks. Whenever I add a block property table the window that should be opent doesn't open. The strange thing is that I think it actualy is open but i just don't see it on my screen. The same thing gous for the screen that allows you to ad a parameter to a lookup set. by folowing this link you can see what i mean, it gets interesting after 30 seconds.
[URL]
Is there a variable that decides where on your screen you see these screens?
View 3 Replies
View Related
Apr 26, 2012
I am having some troubles whit my dynamic blocks.
Whenever I add a block property table the window that should be opent doesn't open. The strange thing is that I think it actualy is open but i just don't see it on my screen. The same thing gous for the screen that allows you to ad a parameter to a lookup set. by folowing this link you can see what i mean, it gets interesting after 30 seconds.
[URL]
View 6 Replies
View Related
Aug 20, 2012
No documentation : remove all property overrides
If I insert a table with our standard table style is is to big, so made a smaller text style, made a new table style with the new text style in it.
And if I insert a new table with the new style its still big...
But... select the table, right click, Remove All Property Overrides... And the text style is OK, only the row height is wrong, so in the table bar - unlocked, select the table again and move the right little triangle up until the rows don't get smaller.
View 1 Replies
View Related
Nov 7, 2012
get the view command back on the list of menu commands as i seem to have lost it.
View 3 Replies
View Related
Mar 27, 2012
I have a strange problem with one of our library blocks.
For panel schedules and light fixture schedules, we have DWG block files, and we insert them into our drawings and explode them for editing.
The light fixture schedule loses all of its font attributes when we do this. It looks fine when you insert the block, but once you explode the block all the font information is lost. Interestingly, if you insert the block and go into the block editor, the block editor doesn't show the fonts correctly even though the un-exploded block does show the fonts correctly.
An important detail in all of this is that the panel schedules are just drawings (lines, text, hatches, etc.). The light fixture schedule is a table.
I'll attach some pictures showing what I'm talking about and the DWG block file.
View 3 Replies
View Related
Sep 11, 2012
I have created a dynamic scale bar block that a user can edit two custom properties of (Horizontal Scale and Vertical Exaggeration) and the values on the scale bar will self-adjust after a regen. The block works fine if inserted into a drawing as per normal the normal insert method.
However, the issue I am running into is this:
If the block is inserted into a template drawing that contains our standard company titleblock (again this part works fine), and that layout is then imported into a new drawing using the "From Template..." right-click option on the Model/Layout tabs, the block loses the custom user parameters. Editing the block definition shows that the parameters are there, they just no longer have names or default values and do not appear in the properties window when the block is selected.
Trying to edit the user parameter names in the block definition of this imported copy of the block, just results in receiving an error that I'm attempting to use characters that are not alphanumeric.
I've tried this same procedure with 2013 and the issues still occur. I've tried user parameter names that don't have an underscore in them (just in case that was causing the issue), but again no luck.
I've attached a simpler block that recreates the same problem: Tester.dwg - this is the block that can be inserted into a drawing. It contains two user parameters "Tester" and "Tester_2". Inserting this block into a drawing shows the block works correctly (user parameters are editable from the properties window).Testing.dwg - this is a drawing that contains the above block inserted onto Layout 1. If Layout 1 is imported into a new drawing (using the "From Template..." right click option of the model/layout tabs), then the block no longer functions as it should. The two user parameters are no longer visible in the properties window.
View 2 Replies
View Related
Oct 22, 2012
I have created a dynamic block and have applied some lookup tables to it but its not working just the way I want it. I think its to do with the custom entry on the lookup tables. If I delete the custom entry when i select the block in model space the drop down select box to allow me choose a selection is no longer available. How can I remove the custom entry and still have the block working normally. I've attached the block.
View 9 Replies
View Related
Jul 25, 2012
I am trying to add a table that I can edit like an attribute but have it in a block, Basically I am trying to put information for all the poles in an electrical panel, but im not using MV parts just a block is there anything that can be recommended in this instance.
Just another note I need to reference 72 poles and 5 colums for each of these.
View 1 Replies
View Related
Mar 21, 2013
I have created a sample drawing, to illustrate to the design manager at work that we can use AutoCAD to assist us with the scheduling of materials, but I am unsure of all the ins and outs of it myself!
See attached drawing to make sense of the following:
Ordinarily we would use a panel reference number for all 50mm panels of identical length, i.e., all 1200mm panels (our standard width) will be assigned a panel code, often P01... etc etc. From the data extraction (EATTEXT) command, as you can see, all 50mm cleanroom panels under the 'name' column are according the block name, in this case, I've called it "Cleanroom Panel 50mm". Is there any way to assign an individual tag to all panels of equal length, yet maintain the same block - or is this simply asking too much?
The reason for this is that although the autocad generated table is ideal for quantifying and placing orders for materials, we are a design and build firm, all our construction workers will need to be able to identify where on a plan an individual panel is, i.e., all well and good to say one panel is 332mm long, and one is 350mm long, but he will need to know what panel is to be installed where...
View 2 Replies
View Related
Aug 29, 2011
I am creating some table of contents. The first column contains symbols that are inserted blocks. Now, when I've created dynamic blocks I've made them to have more visibility states. If I insert the block that has such states, only the saved state is visible. Is there any way that I can use more visibility states when inserting some block into table.
At the moment the only solution is to insert another simplified block that I've created just for this insertion. That way my blocks library is getting bigger and bigger only because of this. I don't use simplified blocks in my drawings, except for the thingy mentioned above.
View 6 Replies
View Related
Dec 6, 2013
I re-opened the desk top opened new file -like usual- and the menu bar was missing the property bar.
I can find it in the lay out and also file- right click-tool bar- standard, it comes up but covers the whole menu bar. How can I retrieve the original file set-up, where it s incorporated in the new file?
View 3 Replies
View Related
Dec 29, 2013
I want to create a Curve table for an alignment.
You are able you get range of properties, i.e length, chord length, start/end chainages, mid-ordinate.
I've notice lets for arguement sake 'chord length' text component editor is: <[Chord Length(Um|P3|RN|AP|GC|UN|Sn|OF)]> but is it possible to modify the code so i can insert half a chord length.
Ive tried
<[Chord Length(Um|P3|RN|AP|GC|UN|Sn|OF)]>/2 ---- doesn't work
<[Chord Length(Um|P3|RN|AP|GC|UN|Sn|OF)]/2> ---- doesn't work
<[Chord Length(Um|P3|RN|AP|GC|UN|Sn|OF)/2]> ---- doesn't work
<[1/2*Chord Length(Um|P3|RN|AP|GC|UN|Sn|OF)]> ---- doesn't work
View 1 Replies
View Related
Aug 7, 2013
I am displaying stationing for my points, the points were brought in with a user defined classification. Then a table was created with the classification.
Base file- table looks good / when I xref the table it loses the station formatting.
I even tried importing all my user defined tables and styles and still didnt work
Civil 3D 2012 SP3
View 2 Replies
View Related
Mar 14, 2013
In our company, we put Excel tables in our drawings. The reason we've chosen for Excel-tables is that we can adjust the layout of the table quite easily. These tables consist of grouped cells in a particular company-specific layout. We select the range of the desired cells, copy and paste them in our AutoCAD drawing. This drawing is sent to our customers. The disadvantage of this method is, that when our customers (who use CAD-software of other brands) open the dwg, they don't see the table, but some kind of picture of the table.
Is there a way to 'explode' the excel-table, but keep the specific layout of the table? For attributes in blocks there's the 'Explode Attributes'-command in the Express-tools, but is there something similar for Excel-tables?
Product Design Suite 2014
Inventor 2012 SP2, Vault 2014
HP Workstation Z220
Intel Xeon 3.4GHz
16GB RAM
Nvidia Quadro 4000
Windows 7 Professional (64bit)
View 2 Replies
View Related
Sep 4, 2012
We use a number of blocks with block tables for data extraction here, and whenever one of the blocks is modified and updated, all of the block tables reset to the default value. This happens for any block reference change, not just changes to the block table (which makes sense that it would reset).
How can we update these blocks without having to manually change all of the block tables afterwards?
View 2 Replies
View Related
Apr 4, 2011
I have a block which contains visible and invisible objects and attributes. I need to export custom block properties, which I added to a dynamic block, like in express tool export attribute information.
or it is possible to convert my custom property, which can contains invisible and visible objects, to attribute value.
View 6 Replies
View Related
Nov 23, 2011
My boss gave me a copy of Autocad 2012. I've messed around with architecture 2010 before so the ribbons are no surprise. One thing I have noticed that's really different is the dynamic block constraints & block table actionblock properties table? I looks very similar to the lookup property table
View 0 Replies
View Related
Mar 7, 2013
It's about "Block Properties Table",I want to use a Block Properties Table to manage a Dynamic Block.
I have defined a Dynamic Block a and its Block Properties Table in Autocad2010,this is the screenshot of the Block Properties Table(a1:d1=100,d2=200;a2:d1=100,d2=400;a3:d1=100,d2=600.) Now I want to insert the Dynamic Block using .NET API.after I input a command,the block of a2(d1=100,d2=400) is inserted. I have the code about it, but the code is not complete. this is the Dynamic Block
this is the the screenshot of the Block Properties Table .
the result:
the code about it:
[CommandMethod("readBlockTable")]
static public void CmdReadBlockTable()
{
Editor ed = Application.DocumentManager.
MdiActiveDocument.Editor;
// select a block reference
[Code].......
View 8 Replies
View Related
Aug 25, 2011
So I'm creating a block with a block table and constraints. The constraints such as Geometric Constraints work just as assumed. When adding in dimensional constraints we start to have more fun. So I have dimensional constraints that use other dimensional constraints to manipulate itself.
EX. dimconC = (dimconB-dimconA)
dimconA is 12
dimconB is 14
dimconC would be 2
Now when ever dimconA or dimconB change dimconC would populate accordingly.
With this I wanted to make an attribute that could be placed in instead of a dimensional constant.
EX dimconC = ((Att1*dimconB)-dimconA)
Att1 is 02
dimconA is 12
dimconB is 14
dimconC would be 16
However when trying to place in formula that references a attribute I keep getting an error "A DEPENDENT EXPRESSION CANNOT BE EVALUATED" So I assumed it was missing an expression from the attribute, however once entering an expression in for it I still get the same error.
(full error message attached)Constraint_Error.JPG
Is this something that is not allowed at all or have I over looked something?
View 2 Replies
View Related
Jan 18, 2012
What are all the block table records?
I've got Model Space & Paper Space(Or Layout Space) under control.
I've got two block reference instances of the same block on a drawing.
If I purge the Drawing the older duplicate block reference disappears.
7867 is the older reference that disappears when I use the purge command.
78A7 is the newer reference, I only want to see this one on my extraction of attributes.
What property of the block reference will tell me that it would be purged if I used the purge command?
As I want to detect what's the old block and which one is the current block reference.
The problem is I only want to extract the attributes from the newer block reference.
The old block reference is coming up... how can I filter that out of my loop results?
I know I could just purge the drawing and my problem would be done with.But I need to do this in a manner that only accesses the drawing from a read-only manner.
View 7 Replies
View Related
May 17, 2012
I have a routine that looks for an MText date stamp and replace the old date with a new date. The problem is some MText strings appear encrypted. Below is an example:
{\H1.121x;\C1; \LFY 2011-12\l \H0.6252x;04-30-11} This is what I should get when I extract the string (as shown in Property window)
(1 . "\pxi-2.1818,l4.3636,ql,t4.3636;{\fSymbol|b1|i0|c2") is what I get when I extract the group code.
I'm running AutoCAD 2012 on Windows 7.
View 2 Replies
View Related
May 30, 2012
I am setting the Custom Properties on a CAD File. The Properties may include "Drawing Number, DrawingName, ProjectName"...
Now using code I want to fetch values of these Properties and set into Layout Title Block.
View 9 Replies
View Related
Oct 30, 2012
I am trying to get an "idw" or "dwg" title blocks "DESCRIPTION" property using an Inventor macro.
For example, if the description property on a part (ipt) file is "SIDE PLATE", how can I can the same result if the file extension is a "idw" or a "dwg"?
View 9 Replies
View Related
Aug 15, 2013
I want to use the File name property in my title block. But i don't want to see the .dwg extension.
Is it possible to not show the extension?
View 2 Replies
View Related
Sep 30, 2013
I'm inserting automatically many references to a couple of dynamic blocks in an AutoCAD drawing using VB.NET. If the number of inserted references is not very big, it works fine but, if I´m inserting hundreds of them, I noticed the app is slowing down a lot.
After taking some measures of the time the app uses in its execution, I noticed changing the value of the block reference property is slower as the number of inserted block increases: it takes 10 or 20 miliseconds at the begining but it can take more than 1 second after inserting one thousand of block references (to the same block).This is the function I use to change the property values:
Protected Sub CambiarPropiedades(ByRef ed As Editor, _ ByRef br As BlockReference, _ByVal nombrePropiedad As String, _ ByVal valor As Double) Dim pc As DynamicBlockReferencePropertyCollection = br.DynamicBlockReferencePropertyCollection If br IsNot Nothing And br.IsDynamicBlock Then For Each prop As DynamicBlockReferenceProperty In pc If prop.PropertyName = nombrePropiedad Then prop.Value = valor '
This line takes a long time the first time I call this function for the ' same block reference but it is faster in the next calls . It also changes the block reference name (br.name) in the first call
Exit For End If Next End If End Sub.
Which I call to change all the properties I need to change in an inserted block reference:
CambiarPropiedades(ed, br, "h_testua", objElementoLaboratorio.POS_TEXTO) CambiarPropiedades(ed, br, "d_texto_hor", posxTexto) CambiarPropiedades(ed, br, "largo", objElementoLaboratorio.LARGO) CambiarPropiedades(ed, br, "fondo", objElementoLaboratorio.FONDO)
A weird thing I noticed is that when I call this function to change the first property of an inserted block, it also changes the .Name of the block reference.
Even if I change the order in the property modification, it takes always a lot in the first call, it does not depend on the property I´m changing.
View 1 Replies
View Related
Sep 19, 2012
Instead of a window popping up with the hatch settings, I just get the following in the command prompt:
Pick internal point or [Select objects/settings}:
what might be causing this?
View 6 Replies
View Related
Sep 22, 2011
I am starting with a polyline then i use the pasteblock command to insert that polyline as a block.Now i can pull up the property box and change the xyz scale.
I would like to know how to change these setting in my lisp.The scale will be x=1 y=0.1 z=1
View 7 Replies
View Related
Apr 18, 2013
Just installed AutoCad 2012 and I have the Property Dailog Box open. I anchor it to the left side of the drawing screen and "Lock" all toolbars in place. When I get out and go back into Autocad, the dailog box is still locked, but it is in the middle of the drawing screen.
View 3 Replies
View Related
Mar 6, 2012
every time I select something a small box pops up in my way with the object's properties. I can't figure out how it became turned on, and don't know how to get rid of it.
View 4 Replies
View Related
Dec 16, 2010
How to change the Scale Uniformly property in dynamic blocks accross hundreds of drawings using either/or scripts, lisp, vba or anything else that might do the job.
I just need to open the drawing and select the block (one block per drawing) then edit the scale uniformly property within the block, save then close the drawing and move onto the next drawing.
View 4 Replies
View Related