Revit :: Modifying Section Tags / Heads
Mar 6, 2013
I was wondering if there is possibly a way to create, modify, or edit the section tags in Revit. I've tried going through Properties> Edit Type to change the size, and type of the tag (or the section head), but i notice there are only seven options, and no way to change the size of them. Is there a Family Type I can edit? Where would I find it? Is there a way to create my own, perhaps, and upload it into my model template?
View 6 Replies
ADVERTISEMENT
Dec 10, 2013
Our company prefers to call out Sections and Elevations with a letter and Details as numbers. How can I make this happen in Revit? Can it happen in Revit.
View 2 Replies
View Related
Dec 20, 2011
Quick easy way to change the default insertion size of the section and callout heads. They're too large.
View 3 Replies
View Related
Apr 20, 2012
I have sections cut from floor plan that show up on my exterior elevations. I am able to stretch the tag ends using the blue dots. I also have placed section marks on the elevations that reference other section views. With those tags I am unable to stretch them up and down on the elevation views. When I try, they disappear. I am not stretching them outside of the annotation crop.
View 1 Replies
View Related
Jul 26, 2013
Revit 2014.
We created floor plans, created actual wall sections. Then we placed countless section markers that Reference Other Views with the SIM text by them. I would expect to go into the roof plan or elevation and see those same section markers. For some reason they do not show in any other view besides the view in which they were placed. The actual wall section markers show up. Just not the ones placed that reference another view.
Same in reverse. Go into elevation, draw a section marker that references other view. I would expect that marker to show in plan. But again no. I have not had this issue in previous versions of Revit. Just so far in 2014 this has been killing me trying to figure it out.
All views are set to Discipline: Coordination, and the original section markers are set to hide on scales courser than 1"=400' so they should show. Visibility graphics has sections turned on. There is nothing that shows with the light bulb.
View 1 Replies
View Related
Feb 23, 2012
Is there a way to turn off all section tags for drawings refering to all Sketch Layouts in all the Construction Document Layouts?
View 4 Replies
View Related
Dec 5, 2013
As I continue my learning of AutoCad on the PC after having been a Mac CAD (non-AutoCad) user for 15+ years, another question has cropped up. My boss wants the circular "heads" of the elevation and sectional callouts to be smaller on the finished drawings. How can I control (or override) the default size of these? Or do I need to override on a case by case basis? I've searched these and other forums and what I am getting a sense of is that AutoCad controls those sizes pretty tightly so they remain annotative and AutoCad sets them at the size it thinks they should be and changing that size is not a simple process.
View 2 Replies
View Related
Jul 3, 2012
I have created a couple text styles which are identical other than the fact that one has pointers using filled arrows whilst the other has filled dots. However when exported to dwfx, the arrows appear whereas the dots are absent!
View 1 Replies
View Related
Dec 24, 2011
Is there any way to get Revit window tags to behave like the door tags? The door tags seem to be instance parameters while the window tags are type parameters. I would like to use separate numbers for each window even though they are the same type. This would allow me to specify header required for each window in the schedule. I understand that I could edit the window families and save them as different files but this is time consuming. Is there an easier way?
View 3 Replies
View Related
Sep 5, 2013
I'm trying to work out how to modify an existing, out of the box Revit family, a window, to create a new one, and struggling with it.
What I'm looking to do is to take the family (from the metric uk template) "Windows_Sgl_Horz_Bars.rfa" and add a second window bar in. What I'm finding is I can copy the window bar extrusion easily enough, but getting it to constrain to the sides of the window frame as the middle one has been done (position not changed from the original) , it doesn't work, when I flex the model I keep getting "constraints are not satisfied" warnings.
When I move the copied extrusion to the sides it looks like it is snapping to the constrain line of the pre-existing window pane, I don't understand why the new alignment with an existing one doesn't work.
I had been looking to generate a lot of new family content by modifying what has come out of the box, if I can't fathom it, its going to be a lot of work.
View 6 Replies
View Related
Sep 1, 2011
I'm a new Revit user and can't seem to get the hang of fill patterns.If I go to Manage>Additional Settings>Fill Patterns Ise a list of a couple of dozen or so fill patterns with the Drafting Button selected.
But when I try to modify the fill region in a family I'm only given a choice of about six of the patterns.how to "load" the other pattern types.
View 1 Replies
View Related
Apr 9, 2013
Is it possible to control if the door tags is displayed by the schedules?
View 4 Replies
View Related
Apr 30, 2010
An architect sent me his revit file, it contains the full model and all the floor plan views and drawing sheets. He has floor plan views set up for each floor and some enlarged views as well. On each floor plan view each room has a tag that contains room name and room number and every door has a tag that contains the door number.
When I create a new file and link in his file so I can then start working, doing what we need to do, adding devices, etc. The problem is, the architect's room tags and door tags dont link in, and if they do I cant see them. I've gone through every possible combination in the visibility/graphics options to no avail.
Room and door info linking in should be a basic function of revit; how could autodesk expect mech, elec, plumbing engineers to create drawings that have zero room and door info?
If it matters, I'm working in Revit 2010.
View 6 Replies
View Related
Jul 4, 2013
I understand that revit is the future and that it is very impressive at doing very complex & mundane tasks, however it does seem to struggle to do the simplest of commands.We wish to be able to put tags (in this case room tags) either in the middle of the room or align them all to each other (i.e if there is a corridor with rectangular rooms on each side of the corridor all tags on the left hand side would be in a single line in the middle of each room, as they would be on the other side).When you place the room it gives you some cross hairs but you cannot locate these in the centre of the room.I have looked for draft line/reference lines/ghost lines and anything that you can put in temporary to use as a guide.
View 9 Replies
View Related
Sep 13, 2012
I placed doors throughout my plan, but the door tags do not show. How do I turn them on and off for doors window etc.?
View 4 Replies
View Related
Sep 28, 2013
Opened the Elevation Tags dialog (manage Additional settings) duplicate the 1/2" Square type call it External Elevation Tag. did the same to 1/2" Circle call it Internal Elevation Tag.
picked the elevation tool go to type selector and my new Elevation Tags not there - why?
View 5 Replies
View Related
Jan 17, 2012
Is there any way to tag a legend component? I'm trying to draw a "door types" drawing which shows the elevation of each type of door and I want to be able to place a title under each door that displays the door type mark. This is a very standard type of drawing that architects draw for almost every project and..after all...what could be more basic to a legend component then to be able to label it?
Now I use text to label each type of door...but if someone changes the door type mark and fails to update the legend also....I get a very un-Revit-like mis-coordination with my door schedule!
View 2 Replies
View Related
Feb 20, 2014
I am working with room tags that has multiple yes/no features. my problem is its hard aligning text because they wont snap to centers or refernece lines. How are people working with this. It causes for sometimes the leader line when used to not want to be straight or leaves some funky angle when change scale
View 1 Replies
View Related
Oct 19, 2011
When I edit a note on a material tag on a wall section it changes multiple tags. For instance I have a wall section with insulation in it and have placed detail components (2x4's) as top and tie plates. When I tag the insulation it shows a question mark, I edit the question mark to the desired insulation note no problems. However when I go to tag the top and tie plates they come in with the same note as the insulation. When I edit the note for the top plate it changes the insulation as well. How do I keep this from happening?
View 1 Replies
View Related
Oct 28, 2013
I have changed the scale of my sheets and the scale of my floor plans to accomadate my new sheets, but now all of my thermostat, wall strips ect. are all way too big. How do I change this?
View 3 Replies
View Related
Feb 21, 2013
Trying to create Area Plan with Tag. Getting message ' no area tags loaded'. Looking at the Library, no Area Tags there. Where could they be? Is there an Area Tag Category Family?
View 9 Replies
View Related
Feb 7, 2013
I works as a lighting designerand I just purchased Revit LT in order to meet some 3D-project managment requirements. I find the lighting fixture families to be very useful and simple to work with but I need some way to identify the fixture types used in the project without acctually clicking each fixture when in plan view. In Autocad 2D i create an text attribute which I block together with my 2D-symbol, is there any way to do a similar action in Revit? I tried to group my 3D-symbol with a text, but that dident work out to good when moving and copying the symbols.
I imagine al types of diciplines would need a similar action to keep track of what is drawn?
View 3 Replies
View Related
Jan 19, 2012
Is there a way to display the HW Group within the door tag? I'm working on a new door tag for our office, and they have requested that HW Group #s be displayed, so the door installer knows which hardware group to install.
I find type parameters (width, Mark, Manufacturer, Etc) but no Instance parameters (HW Group, door materials, etc)
Would I need to make a shared parameter for this?
I can schedule HW Groups, so shouldn't I be able to tag them as well?
View 4 Replies
View Related
Sep 14, 2013
I modified a Window Family file by adding a Window inset parameter. When I inserted the window into a wall, otherwise the window worked fine, but when I changed the window's Window Inset value, the frame depth changed instead of the frame's location. The frame was originally made by Sweep tool, but now when I made it by Extrusion tool, the window works fine. Anyway, for future purposes, I would like to know how to be able to use the Window Inset parameter with a frame made by Sweep tool. How do I lock the depth of the frame sweep?
The file is attached.
View 2 Replies
View Related
Feb 5, 2014
I am creating a room tag with various family types. unlike creating other families when I am in the family editing and I click through other types it hides the objects that are only visible for the proper value. How do I do the same. Being that I have a few types its getting sort of hard to see with the different amount of texts.
View 1 Replies
View Related
Jan 31, 2014
how to make room tags than can break in two words and possibly how to remove the symbol crossing of area.
View 1 Replies
View Related
Oct 17, 2011
Is it possible to have a break in the 3D Section Box View (axonometric view)? Such as a jog in the section box to follow the building??
View 2 Replies
View Related
Apr 27, 2011
When I add a section tag to a dense area of an elevation, the detail number and sheet number often get lost in the clutter. How can I hide the content behind the callout head?
View 5 Replies
View Related
Nov 12, 2012
When I exported my project from Revit to Autocad Software Section line is not displayed.
View 2 Replies
View Related
Apr 3, 2012
I can't get Revit to display the cut material of a stair (landing or run) in 2013 using the new stairs... i have tried different settings in object styles, visibility/graphics, materials, details levels, phasing all without success.
Successfully show material cut pattern on a stair in section?
In the attached i have the new "Component" stair next to the old style "By Sketch" stair, the sketch stair shows the cut pattern the component one does not, this is the same section view not two sections.
View 2 Replies
View Related
Jul 10, 2012
I am working with Revit 2013 and wondering how (if it is possible) to set Section line in right position "X, Y" (coordinates).
View 2 Replies
View Related