AutoCAD Inventor :: Hide Scale In Section And Detail

Sep 27, 2011

The only topic i've found is old so I would like to ask if there is a possibility nowadays to turn the scale defaulty OFF.

[URL] ......

View 2 Replies


ADVERTISEMENT

AutoCAD Inventor :: Detail Boundary And Section Line Scale Is Different?

Sep 11, 2006

Inventor 11 - Sp1

Why is the scale of my Detail Boundary line different than my Section Line scale? I have set the global line scale so that hidden and section lines look OK, but the detail boundary line spaces are so close that it prints as a continuous line. I am using the same line weight and line type for both detail and section lines.

View 5 Replies View Related

AutoCAD Inventor :: Scale Detail Cross-section Hatching In Drawing?

Aug 7, 2013

Is it possible to scale the cross-hatching in a detail that was created from a section view so it looks better with the scale of a detail? If the scale factor of a detail is much larger than its parent, the cross-hatching is very sparse and detracts from clarity rather than adding to it.

View 2 Replies View Related

AutoCAD Inventor :: How To Hide Solid Body In Detail

Dec 4, 2012

I have created two solid body in the modeling mode &maintained seperate body ( Didn't combine) there after hide & visibility off  one solid  body .while taking the detail that time two solid body is appearing. how to switch of the body in detail.

View 9 Replies View Related

AutoCAD Inventor :: Remove Or Hide Cutout Shape Line In Detail View

Oct 17, 2012

when we are taking details view ther is two type cutout shape 

1.smooth shape

2.jogged shape

i need to remove or hide the cutout shape line in detail view. it is possible.

please find the attached file for detail.

View 6 Replies View Related

AutoCAD Inventor :: Section And Detail Views

Jul 1, 2012

Is it possible to copy a section view or detail view from one sheet to another, without having to copy the base view?

If so how?

If not, why?

View 1 Replies View Related

AutoCAD Inventor :: Annotation On Section And Detail Views

Mar 26, 2013

im trying to make an template we can use as default template..

now when i make a section view or a detail view of a part, the annotation is placed above the section view..

I would like to have that underneath the view.

I know can drag it down there, but is there a way to have the annotation underneath the view when its created? would save me and the rest who is going to use the template a lot of time..

View 2 Replies View Related

AutoCAD Inventor :: Detail And Section Views Blowing Up In IDW

Jun 6, 2012

Working with Inventor 2012: I have a rather large assembly (over 3000 parts) that was worked on by an outside engineering firm and includes several different Levels of Detail & Views under Representations. When they originally Pack 'n Go-ed the whole assembly and related .idw's over to us, all the .idw's seemed to show every view correctly without errors.

However, I've now went into the assembly and made several modifications to the overall master assembly and a few sub-assemblies within it (adding/deleting a few parts, nothing major). Now when I try to open a few of the master assembly .idw files, all the section & detail views have become full model views, losing their "cutaway" views. See the attached before & after pictures.

I've went back in to each .iam and made sure that the level's of detail & Views match the way the file was originally given to us but I can't seem to get the cutaway views back again.

View 9 Replies View Related

AutoCAD Inventor :: Customize Fence Labels For Detail And Section Views?

Jul 9, 2012

Is there a way to customize the fence labels for detail and section views? 

I know we can edit the label directly and add/remove text, but is there way to change the appearance of the label as well, with say a sketched symbol or other graphical representation like a balloon or other customized image?

View 4 Replies View Related

AutoCAD Inventor :: Hide Section Of A Visible Line In Presentation

Nov 27, 2013

One of my draftsman is trying to put an identification Tag on one of our assembly.We made a symbol with our tag, and we put it on whatever where trying to identify directly on the presentation.

Our problem is that where not able to remove whatever is behind that symbol so that we can make that Tag readable.Is it possible to make only part of a line invisible in our presentation?

View 9 Replies View Related

AutoCAD Inventor :: Hide Hatching Of Part Within Section View?

Mar 8, 2013

I have a cylindrical shaft passing through a bearing.  I have a section view showing a cut-away of half of the shaft and bearing.  Automated hatching results.  I bring the bearing out of the section view (Rclick > Section Participation > None), and the hatching of the shaft remains visible, through the bearing. An image of this is shown below:

I would like to hide that hatching that shows through the bearing, so that it looks like the image below: 

How can this be done?

View 8 Replies View Related

AutoCad 2D :: How To Hide Dimension From Viewport And Show It In Detail

Jan 31, 2014

I have a drawing with a detail, I want to hide dimension from the big view port and show it in the detail as you can see in the picture:

I use Annotative dimension.

View 3 Replies View Related

Revit :: Section And Detail Targets

Jan 18, 2012

I put in building section targets and detail targets. When i opened it the next day some were missing from the drawing but the building section and detail views still exist. Where did the targets go/

View 1 Replies View Related

Lightroom :: How To Recover Detail Section

Dec 28, 2013

How to recover the Detail section, which includes sharpening, in the Develop module of LR 5.3?

View 2 Replies View Related

Revit :: Customizing Section And Detail Heads?

Dec 10, 2013

Our company prefers to call out Sections and Elevations with a letter and Details as numbers. How can I make this happen in Revit? Can it happen in Revit.

View 2 Replies View Related

Revit :: Hide Content Behind Section Tag

Apr 27, 2011

When I add a section tag to a dense area of an elevation, the detail number and sheet number often get lost in the clutter.  How can I hide the content behind the callout head?

View 5 Replies View Related

Revit :: Label (detail / Sheet Number) To Rotate With Section Tag Rather Than Remaining Horizontal

May 5, 2010

Is there a way for a label (detail number/sheet number) to rotate with a section tag rather than remaining horizontal?

Is there a way for the same label to flip along the main horizontal reference plane of a section tag?

We do not use the traditional circle head and when the head needs to rotate or flip the 'pointer' lands on top of the label.

I think I have exhausted all combinations of checked/unchecked boxes for 'Keep readable' and such.

View 7 Replies View Related

AutoCad 2D :: Cross-section / Elevation And Detail Cross Reference Labels

Apr 6, 2011

I am trying to annotate a floor plan to show the location/orientation of section, elevation and detail drawings. The labels must also indicate the appropriate drawing cross reference. (basically a circle with a arrow, text inside circle showing drawing cross reference). My question is - is there an automated way/library to insert such labels or do I have to create each of them from individual elements and make a block?

View 1 Replies View Related

AutoCAD Civil 3D :: Section Text Scale

Jun 12, 2013

I have a 50 scale drawing and my section views are 10 scale. The text size is correct in paperspace viewports, but is much too large in model space, and makes it difficult to work on the sections in model space. (I've attached a pdf of sections in model space).

View 7 Replies View Related

AutoCAD Civil 3D :: Section Sheets Annotation Scale?

Mar 29, 2012

I have created section sheets in C3D 2012. My sections look fine in model space and my template comes in in paper space with my template and the proper viewport (viewport scale is 1:200). My annotation scale in model space is 1:250 and everything looks fine. My problem is, in paper space, the sections themselves looks fine but the annotation is way out to lunch (see attachment). I've tried playing with the scales but can't seem to find a solution.

View 1 Replies View Related

AutoCAD Inventor :: Calculate Section Modulus On Certain Cross Section Of Solid Part?

Dec 9, 2013

I am trying to verify the bending strength of a solid part. Need to calculate the section modulus on certain cross section. Don't know how to do it using inventor.

View 7 Replies View Related

AutoCAD Inventor :: Incorrect Radial Section View - Section Participation None

Sep 24, 2012

The section view behaves strangely with the ‘section participation: none’ components

Invertor2012 sp2
Win7 x64

View 6 Replies View Related

AutoCAD Inventor :: Section View Not Parallel With Section Line?

Nov 19, 2011

why my section is not parallel with my section line. I did constrain my section line in the section line sketch.

View 2 Replies View Related

AutoCAD Inventor :: Section An Assembly In Breakout But Not Section

Sep 24, 2013

In the drawing view below, I want to section the green assembly only within the red section.  I've tried this with a breakout and it doesn't work.  There doesn't seem to be a way to exclude the green from the section and yet include it in the breakout.

Infrastructure DSP '14 / Product DSP '14 / Vault Professional 2014
Dell Precision T1650
Windows 7 Professional SP1 64-bit
Intel E3-1270 V2 3.5GHz / 32G RAM
Nvidia Quadro 2000, Driver 331.82
Space Navigator, Driver Version 6.17.7

View 3 Replies View Related

AutoCAD Inventor :: Top Section To Blend Into Bottom Section?

Jan 11, 2013

How can I revolve the top section to blend into the bottom section.

View 2 Replies View Related

AutoCAD Civil 3D :: Section View Scale Labeling - Wrong Text

Jul 12, 2013

In civil 3d 2014 i need 2 sections (and a profile) all with different scales in the viewports (layout). Sizing of the labels and bands is all fine, only a text item is not updated. I need to display the scale (the number) for the current section (or profile), it works but the scale shown is always the scale from the model and not the scale from the viewport, so the different scaled sections all have the same text in the label, e.g 1:200, even if they are correctly scaled to different factors in defferent viewports.

View 5 Replies View Related

AutoCAD Inventor :: Scale A Part With Different Scale Factors In 3 Directions

Apr 15, 2013

I have a 3D part, which I want to scale down to 0.5 the size in X and Y direcions, but I don't want to scale it down in Z direction.

Is this even possible? How do I go about doing it?

View 9 Replies View Related

AutoCAD Inventor :: Circle Around Detail View

Nov 30, 2011

How do I turn this circle off?

View 6 Replies View Related

AutoCAD Inventor :: BOM Export Using VB And Levels Of Detail

Apr 16, 2013

I need to export our BOMs from inventor into a csv file that can be loaded into our ERP system. All of that code is working great and the help files were useful in getting this completed. However it only will work if the assembly model is in the master level of detail!! This is not good at all since the only reason we use levels of detail is becasue our main level assemblys are 1000+ comp and our computers cant function with these levels of models in the master level of detail!! Is there anyway around this?

View 2 Replies View Related

AutoCAD Inventor :: Turn Off Detail Circle

Jun 26, 2012

I would like to highlight connector cutout details on a panel using the circular detail feature.

The views created are fine, however the detail indicator, the circle with arrows and identifier clutter the face of the object. If i could turn them off i would then use a leader to point to the detail instead, which in my case will be much neater.

View 2 Replies View Related

AutoCAD Inventor :: Link Levels Of Detail Via API?

Apr 23, 2012

Is it possible to use the 'Link Levels of Detail' command via the API ?

I can activate the command by using the CommandManager
 
oContDef = ThisApplication.CommandManager.ControlDefinitions.Item("AssemblyBonusTools_LinkLODsCmd")oContDef.Execute
 
But the command then requires a UI selection - I want to select the iLogic LOD.

I've tried using the CommandManager.PostPrivateEvent but to no avail.

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved