AutoCAD Civil 3D :: Getting Error While Building A Corridor
Nov 5, 2012
I'm having problems with Autocad Civil 3d 2012. I'm building a corridor of a curb gutter and sidewalk with a daylight of 2:1 on top of an EG surface. The corridor works for about 3/4 of the length but the last section won't connect the daylight to the existing ground surface. There are multiple sections of the corridor with different assemblies.
Here is a more detailed error report:
Type: Error
Date: 11/5/2012
Time: 9:15:06 AM
Source: Roadway
User: engintern4
Description: 6+80.00': Failed
Point Outside Surface.
Offset: -7.542'
Elevation: 85.776'
Corridor: CURB-GUTTER-SIDEWALK CORRIDOR
Baseline: Gutter Alignment
Alignment: Gutter Alignment
Profile: Gutter Profile
Assembly: SIDEWALK-CURB-GUTTER-DAYLIGHT
Assembly Baseline:
Subassembly Group: Group - (3)
Local Subassembly Name: DaylightMaxOffset
Global Subassembly Name: DaylightMaxOffset (Left) - (50)
Assembly: C:ProgramDataAutodeskC3D 2012enuC3DStockSubassemblies.dll
.Net Class: Subassembly.DaylightMaxOffset
Source: AeccDbMgd
I get about 33 of these errors each time the corridor rebuilds. I'm not sure whats going on, the corridor has targets set for the surface and still won't connect to it.
View 2 Replies
ADVERTISEMENT
Jul 1, 2012
I am getting this error when I am trying to create a surface from my corridor. Instead of just defining a surface along my corridor it is trying to connect all contours lines between different parts of the corridor
When creating the surface I define 2 surfaces, one with overhang correction as top links with links data set as top, and a second with overhang correction as bottom links with links data defined as datum. I have then defined the boudaries using add automatically-daylight. I have followed this procedure for 5 previous corridors with no issues (ie the surface matches the corridor) so is there anyway I could have done something different.
View 4 Replies
View Related
Jul 16, 2012
Using Civil 3D 2012 SP 1 on Win7 Pro 64-bit.
Is there any reason why a corridor model would not be respecting the manually entered super elevation values in the alignment? I have several stations that should be calculated with even super elevation values, but they aren't. For example, at station 0+080 on my alignment the left crown should be running at -3%, but it is actually being calculated at -2.47%. It isn't just one station; it's most of them. No overridden stations, vertical targets, etc in the corridor. Just a fairly straight-forward align (hor/vert) with super, simple assembly (two lanes, shoulder, daylight), simple corridor.
View 9 Replies
View Related
Nov 6, 2013
I'm getting several messages saying "value on wrong side of alignment" when I rebuild my corridor. I've checked the two target alignments that I'm using and they are on the correct side.
Civil 3D 2014
View 2 Replies
View Related
Jan 17, 2013
When trying to make an existing features corridor when I select Target to set the existing surface I get an error
"No target found in the scripts."
I have attached a word file with the error as it appears on the screen.
View 5 Replies
View Related
Jul 9, 2013
When I run my corridor I get an error message that says "Failed Target Not Found" it is for the subassembly provided by WisDOT called UrbMedian.
View 4 Replies
View Related
Sep 14, 2012
I have created a surface from a corridor. I set the boundary of the surface to the daylight of the corridor. In some areas of the corridor the surface does not triangulate see attached.
View 2 Replies
View Related
Dec 13, 2012
Copy a corridor successfully? I'd like to try this just a little worried about the explosion of evil this may cause to my Civil 3D session.
Even all the properties of the corridor setup from one to another would be useful. I'm building one corridor and an 2nd one that matches everything except I need to replace my Assembly with one meant for stripping.
View 9 Replies
View Related
Mar 21, 2013
My corridor surface is not matching my corridor top links. see attachments. this is affecting my volumes!
The section-plan(surface red).png is showing the section editor and the plan view. the red highlighted line in section is the corridor surface and as you can see in plan view the surface is incorrect and wiggly.
The pdf is all my sections with the red linework being the corridor surface.
C3D ver 2012
Win 7, 64bit
View 2 Replies
View Related
Oct 31, 2013
I am attempting to x-ref a building model that was drawn in 2013 MEP in a Civil3D drawing that contains the site surface. When I x-ref my building model into the site drawing and attempt to align and scale the building some of my walls become broken and missing. I have a feeling this is a scaling issue because on my site my north wall should be 24' long. The wall is 24' long in MEP, but that same 24' from Civil3D is only a 2' line segment in MEP. How to remedy this? I have tried scale the building model down in MEP first and it causes all kinds of problems with the door and window objects. I tried adjusting the x-ref scale prior to adding the x-ref and it does the same thing.
View 9 Replies
View Related
Apr 26, 2013
I've got a tool palette that I use which has about 5 or so tabs with about 10 to 50 standard blocks, tables, etc in each tab that is organized by text headers and dividers. It's such a productivity booster I exported the palette to a place on our server that everyone can import them from. My problem is that when they import the tool palettes, the icon images dont come in. We're left with manually updating all the images which is a problem when certain people "don't like change" and don't want to take the time to deal with the technical problems. Maybe I'm missing something, but shouldnt the images come in when you import the palettes?
Andrew Ingram
Civil 3D x64 2012
Win 7 x64 Ultimate
I7 3820 (3.6ghz quad core with HT)
32gig RAM (Corsair XMS3 4x8g)
Intel x z79 mobo (BOXDX79TO 2011 socket)
Radeon HD 7850 2gb GDDR5
View 3 Replies
View Related
Mar 11, 2013
I have created a building pad on my site and need to extract fill quantity. I set the elevations on my building and created a 5:1 grading object. to the existing ground.Autodesk Instructions are, for the actual building footprint, that I need to create a grading object at 1:1. for the area covered by the actual concrete pad. Need screen shot of the style settings of this grading criteria. because the area is flat it is impossible to determine if the floor area has been built. When I run sections and create volume reports the only fill quantity is from the grading objects that slope out from the pad. I must be overlooking a setting in the style for 1:1.
View 6 Replies
View Related
Feb 1, 2013
I am building an assembly for a shoulder widening. the sholder is 5' paved plus 5' stabalized tying to existing grade at a 4:1 slope. The two shoulder sections are showing up in the cross section but the tie-down is not. I have checked the target and it is set properly to the existing ground.
See below.
View 1 Replies
View Related
Oct 12, 2012
I have an existing ground surface with all different z co-ords and im trying to add three proposed buildings to my exisiting ground with all the builidngs having a level of 32.5 as a minimum, however at some points the ground is higher than 32.5 and I only want to raise my existing ground to 32.5 within the proposed buidling layout if it is below 32.5 as im doing a flood calculation. What do i need to for this?
View 2 Replies
View Related
Jun 24, 2013
I am developing an application for C3D using 2010 vb.net. How to build a list of Point File Format names using PointFileFormatCollection and PointFileFormat methods? How to extract the names from PointFileFormatCollection.
View 5 Replies
View Related
Aug 7, 2012
Is it possible to use a custom properties within part builder to calculate pipe sizes?
Within part builder I have created a new parametric part under the rectangular pipe chapter.
This new parametric will represent a electrical conduit ductbank that will vary in size depending on the number of conduits in the ductbank. For example a 2 x 3 ductbank would have 2 columns and 3 rows of a 3" conduit. So the width and height of the rectangualr duct bank would be calculated this configuration. I will have up to 12 rows and coluimns in a single ductbank, so I might have a 10x10, 3x12, 12x 1, etc.
I have a custom pipes catalog and within the AeccPartParamCfg.xml I have created 2 custom propertes named ROWS & COLUMNS.
My question is can this custom property be used to calculate the the height & width on the rectangular pipe within part builder? Once I draw my pipe I would like the ability to edit ROWS & COLUMNS within the Pipes Properties to change its size. is this possible? See image below.
View 3 Replies
View Related
Sep 4, 2013
When working with multiple building pads and configurations change rapidly. Is there a method to add a Block or Xref into a Civil3D Surface under Drawing Objects? If so, how could you do it.
I want to have a building block type 1 that I can update the block or xref then updates the surface rather than doing each one individually. The Block would have a FFE of 0.00 and then the stoops, etc would either be a 0.1 drop or so.
View 4 Replies
View Related
Jun 20, 2013
I have a Proposed Building Pad. Grading is 3:1 on 3 sides. Grading is 5:1 in the front of the building. How do I get Grading to fill in the area at the building corner between the 3:1 and the 5:1 grading? I thought infill would accomplish this but it seems to have no effect when I select the objects. I included a screen shot and the area at the left corner of the building.
View 4 Replies
View Related
Jan 2, 2014
I am working on a project where I need to bring in multiple building site files from Revit as .adsk files to one Civil 3D model. The first building always imports just fine. For any building after the first, I get the following message:
"The selected file contains a definition of a building site that is already in use."
"What would you like to do?"
"Update the definition of the existing building site (cancel the import and use the selected file to update the definition of the existing building site.)" - THIS OPTION REPLACES THE FIRST BUILDING WITH THE NEW BUILDING I HAVE SELECTED
"Browse to another file (display the file browse dialog to select a different file.)"
My team and I have tried every we can think of including the following (see attached):
Renaming the files Moving the files to different folders Importing each building site into a new file and copy and pasting into the model (this works until someone tries to import a building site, which will inevitably happen and ruin this work around)Double-checking all related settings.
View 2 Replies
View Related
Mar 17, 2013
I am using AutoCad C3D. I have drawn a building and now I am trying to position the building on a plot with uneven property lines using only “tie distances” from the spots on the property to specific spots of the building.
I do not know which C3D program functions (with just distances known) to get the building placed properly on the plot.
View 9 Replies
View Related
Jun 13, 2013
C3D 2014
when I created a Top surface, C3D showed me otherwise. I need a gap at an intersection. In the attached DWG the intersection corridor has been removed from view by isolate.
I used 2 seperate baselines to force the road corridor to have a gap at the intersection.
Looked OK .. except ..later .. when I created a Top surface, only the first baseline is used to create the surface, the second baseline is skipped : (
I obviously did not make a gap correctly. What is the correct way? Or.. is there no way .. must the designer create multiple seperate corridors when the road has gaps?
View 3 Replies
View Related
May 2, 2013
I have a very basic question about creating corridors. As you can see on the attachment, i created an assembly consisting of ditch and my own polyline subassembly and turned it into a corridor. The ditch part is drawn out correctly, but the other part (supposed to be a gravel road) has only sections in certain points.
View 4 Replies
View Related
Dec 29, 2013
I started playing around with 3d dwf's. I'd like to share my corridors in a 3d dwf viewer or something similar but when it opens in design review, everything is skewed/ jagged/garbled. The other problem is that it exports everything (assemblies, alignments, sections etc.) so it make viewing navigation difficult in the viewer for people that aren't CAD savvy to begin with. It would be ideal if you could select what you want to export similar to exporting a wmf file.
How do others share 3d models with non-cad people?
View 1 Replies
View Related
Mar 21, 2012
When i try to create a material list, i don't see my corridor surface - just the EG surface appear in the list.
View 2 Replies
View Related
Nov 18, 2013
We are trying to edit a small portion of an existing corridor by adding a generic daylighting subassembly. The add subassembly tool in the Corridor Section editor works, but we get an error because the new sub doesn't have a target surface specified. how to add a target for a sub that is added after the corridor was created?
Civil 3D 2012 & 2013 & 2014
Toshiba Qosmio X505-Q890
2 x i7 - Q740 quad core CPU's
8GB of RAM
60GB SSD + 500GB HDD
NVidia GeForce GTS 360M - driver 8.17.13.0697
Win 7 Home Premium
View 9 Replies
View Related
Feb 7, 2013
When creating an alignment from corridor feature (ditch invert level), the created alignment is not following the selected line (see image bellow). The alignment seams to be created from the first point of the feature line to the last point and ignores all the other points. The vertical alignment created at the same time seams to be correct.
View 1 Replies
View Related
May 16, 2012
I am trying desperately to create a corridor in C3D 2013.
I have the requisite Alignment, Profile and Assembly, yet when I create the corridor, either nothing appears, or it creates the corridor at incorrect elevations. I have the proper elevations in my alignment.
View 7 Replies
View Related
Mar 20, 2012
I had a grading plan all set, with a corridor involved. Then, I received a new survey that I didn't know was coming. I need to move all of my elements to different coordinates. I can move everything except the corridor.
View 2 Replies
View Related
Jun 13, 2012
How to get rid of this gap? Everything I have tried just causes overlaps.
View 1 Replies
View Related
Jan 11, 2013
I only get 2 choices when selecting corridor feature line to create profile - ETW_base, and ETW_sub. My Subassembly has 2 pavement sections, a base and subbase section. I need the top of pavement profile.
View 2 Replies
View Related
Nov 6, 2013
I have a corridor with intersection.The intersection isn't 90 degrees. Can I cut corridor with(for example) 45 degrees?
View 9 Replies
View Related