AutoCAD Architecture :: Change Multiple Door Swings At Once
Jul 19, 2013
I'd like to change multiple doors ( & multiple styles) so I can close them all. Is there a way ?
I think you can only change them in "properties" if they are all same style.
View 1 Replies
ADVERTISEMENT
Mar 5, 2012
ACA 2011:
I created a Dr & Wdw Assembly w/ 3 French doors w/ 3 Transoms above. It looks great. However, the door panels in Plan view are closed. Yet the in the properties dialog box it says they're each 90 degrees open. I can change the number, but the door remains closed. What needs to be tweaked?
View 2 Replies
View Related
Aug 14, 2013
In my xref drawing I changed the linetype of a swing to be hidden. After changing it in the xref and saving I go to my plot file and the swing is still continuous. Visretain is set to 1. The swing changes on all other drawing files except one.
View 2 Replies
View Related
Feb 28, 2012
I working on a deadline with little sleep, but I cannot believe it is this hard to get an overhead door to look right. All I want is a 1" thick frame, the same depth as the wall AND the door slab to be INSIDE the frame like a real overhead door.
The attached PDF shows the standard OH door on the left with the stupid door centered in the frame. The door on the right is one I created by inserting a cased opening in the wall, then manually drawing a rectangle and dashed line for the OH swing. All I am interested in is getting this right in plan at this point. Using Architecture 64 bit.
View 9 Replies
View Related
Feb 14, 2012
I have ACAD Arch 2012 and I am trying to associate my door tags with my door schedule and visa versa. I get as far as creating the Door Schedule with all the doors on it and quantified just the way you would want to see it; however, the "Mark" remains "A" for every door. I discovered that I can change the Mark on the extended properties of each door, but I believe there should be a better (and more linked) way to accomplish this. Since the program already recognizes how many doors there are of a specific style it should be able to put sequential "marks" to each door, for example "A", "B", "C", etc.
what's the difference between Door Tags - Project Based and regular Door Tags?
View 1 Replies
View Related
Apr 29, 2004
--Is there a way to do a door schedule by styles rather than individual door?
--To clarify: I want my door schedule to create a new door number only when one or more of the property sets, classifications, or door styles pertaining to a door are not defined by other doors in the schedule. This would facilitate giving the same door number to multiple doors that have matching schedule information, and cut down on my schedule size.
--how to do this. If I need to create custom tags, schedules, or formula properties.
View 9 Replies
View Related
Nov 27, 2012
Is there any way to change the msltscale variable to 1 and the scale to 1/4"=1'-0" in multiple drawings without opening each and doing it all manually?
View 9 Replies
View Related
Jul 4, 2012
I made a door tag, tagged all 128 doors and during a check set noticed that the text in the tag is the wrong font. I opened the tag and changed the font, saved and regenerated the drawing. The font in the current door tags did not change. To be sure I changed the correct tag I added a new tag and the font is correct. Why do the current tags not update? Do I need to do something? I do not want to go back and redo all 128 door tags.
View 2 Replies
View Related
May 26, 2011
In the attached image, the left is my 1st floor RCP, which looks the way I want. The right is my 2nd floor RCP, in which I cannot get the door jambs (orange lines) to turn off. Cut Planes are set identically in the two dwgs. I thought the Display Configuration settings were identical in the 2 dwgs, but clearly they're not.
View 4 Replies
View Related
Feb 20, 2011
Currently our door schedule populates when the doors are inserted into the drawing. I would like to know if I can set the schedule up so it populates when the door is tagged. Our doors are inserted into a base plan and that base plan is xrefed into various sheets.
The doors are tagged in one of these sheets and not the base plan. It takes too much time to stop and set up the schedule to schedule the doors across the xref for every project we do. I have read several articles but none of them explain how to schedule from the tag that I can see. I thought this was how the schedule was set up in a previous version.
View 3 Replies
View Related
Jul 1, 2012
I am trying to number my doors, and the door tag (AEC6_Door_Tag), won't let me create door numbers with 3 digits. I have never had this problem before. It keeps creating tags with 2 digits.
View 6 Replies
View Related
Oct 18, 2012
I have an assebly with the door going down to grade level and the flanking windows 30 inches up. I used a profile to create the assebly shape. In plan you cannot see the brick below though you can see it between the assemblies.
View 5 Replies
View Related
Aug 19, 2013
We do residential design, our doors and windows need to read 3068 and 3050 etc. I have tried everything but I cannot simply get it to work.....This is what I have done:
*Insterted a door tag from AA2014
*I exploded the tag twice and deleted the circle around the text
*Renamed the nested block and edited to include "OORSIZE"
*Went to style manager/the plan/Doc Objects/Door styles/definition/ changed it to read "STD Door Description"...
see attached file.
View 9 Replies
View Related
Feb 12, 2013
i have created a door schedule and it seems to be missing the most important part, the sizes! When I go into Style Manager and click on the door shcedule and try to add columns size does NOT come up as a choice. I have added size to the property sets of the doors. I have tried everything I can remember from older versions of Autocad and it just won't put in this bit of information.
View 6 Replies
View Related
Sep 9, 2011
Is there a way to disable the ability to Flip the swing orientation of a door so that a RH inserted door cannot be changed to a LH?
View 2 Replies
View Related
Jun 11, 2013
ACA 2012: Is it possible to add a column to my door and window schedules that automatically shows the area of the door/window(or area of Glazing) and then have a total area column at the bottom of the column?
View 3 Replies
View Related
Jun 10, 2012
We've created our own door tags. Now in ACA 2013 the doors that have sizes that end in zero (like 3'-0") are showing a zero, a decimal and three trailing zeros in the zero value.
View 2 Replies
View Related
Sep 1, 2011
how one would go about creating a garage door that slides around a cruved 90 degree track? I.E. has 5 VERTICAL divisions and slides around a curved track to rest flat against an adjacent wall?
View 1 Replies
View Related
Apr 11, 2012
I have created custom spaces and I have been able to build room with doors and then add a door tag that updates automatically with the info of the door. But for some reason, I am unable to assign the door to the space. I am not using project and I think that may be my problem. I feel as though I am almost there, but I can't assign the door to the space so that when I add a door tag it recognizes that the door is in a wall in a space and then gives me those numbers. If I click on the tag, I am able to anchor it to the space and then the room number appears in the tag, but I was hopnig to have it do it automatically. I have the door squiggle inside the space but I don't know how to attach it and also the space seems to have a number project based assigned to it, but that is not what I want since the drawing is not project based.
View 2 Replies
View Related
Feb 1, 2011
Is it possible to add an architrave to a door opening automatically.
I.e wall is 150mm thick and door is 1010mm wide and 2100 high. can the architrave go round the edge of the opening and adjust if the door shrinks to 910mm
View 1 Replies
View Related
Jan 10, 2012
I'm new to Architecture Desktop (especially 2012), I dabbled with it a little bit years ago.
I'm doing a floor plan and I want to change one door to a double door. I changed the style and it changed all the doors. So I did a search and saw something about doing a style override in the "Edit Object Display." So, I checked all the "Object Override" boxes in there. Buuut...when I right click on that door and do "Edit Door Style" it still changes ALL the doors in the drawing to double doors.
View 5 Replies
View Related
Feb 4, 2012
Is there any to get the single line display into the medium or medium low rep by object? I see the only place to get it is to use the High Detail rep by object. Normally in a high detail would you not want a double line for doors? and use a single line for concept in the medium low? I would like to see the ability to have the single door in all display reps by object
View 4 Replies
View Related
Jun 19, 2013
I'm new to the architecture package, but not AutoCAD. I just got training and this has stumped my instructor and me. We use half doors in our buildings and can't figure out how to design one. The door and frame that will finish @ 42" AFF.
View 3 Replies
View Related
Jul 23, 2011
All my layers are turned on, when in an existing drawing my schedules do not appear when I use the tool to create them. When I open a new drawing draw a wall and a couple doors, the schedule inserts when I use the annotate tool. I am only using a basic floor plan at the moment, no xrefs or anything else, simple walls and doors and inserted from the program. I did use tags for the doors and windows which worked fine.
View 4 Replies
View Related
Mar 6, 2011
I need to make the door schedule have the room name in it. I am using the project based door tag so it is already numbered like the room tag.
View 2 Replies
View Related
Oct 14, 2009
Like in a hospital. How do you do that? Treat them as seperate doors? Door and window assembly would be 2 doors in the schedule. Our schedules only schedule one leaf size.
View 8 Replies
View Related
Mar 7, 2011
Using ACAD Architecture 2011
Have a problem with door numbering and xref's.
Drawings are set up with similar insertion points at 0,0,0.
Basement and 1st floor in scope of project. Drawings are xrefed into one another but they are overlay NOT attached.
Smart room spaces, room names, doors and door tags have been inserted into both plans for each room.
In the individual xref drawings, the door tag number coinsides with the room number as it should.
An automated door schedule has been produced and it works well. All room numbers are correct.
When xrefing the 1st floor and basement floor into the same sheet file for a CD document, the door tags on the basement doors, B101.1, B102.1, etc. are taking on the numbers of the first floor area just above it, 137.1, 137.2, etc.. This only occurs in the sheet file not the drawing base files.
When I unload xrefs of both the 1st and Basement drawings in the sheet file....save...close the drawing....reopen....then reload the basement xref only....the tags on the doors in question cannot find the correct number of the room. (message "space not found is displayed")
Then, when I reload the the 1st floor in the same sheet drawing and reload the basement floor again, the door numbers on the basement plan take the 100 series room number from the space above.
The Room name and number tag does not change in the xref, only the door tag.
When I detach both files from the sheet and xref the basement file only....the doors show up correctly. Then when I insert the 1st floor, the door numbers get screwed up again.
This has happened on another project in this office but in that situation 2 different floor plans were NOT inserted into one sheet. In that matter, we had to detach the xref and then load again in order for the door numbers to come out corrent.
After the drawing was saved, closed, and then reopened the door number were again wrong and picking up the door numbers from above or below.
Is this a bug in ACAD 2011? Is there a toggle switch somewhere that will fix the issue?
Using blocks established and populated while in 2008 ACAD. Does this matter?
I move the xref in the sheet file so they don't align. I have move them 500' away from one another. This did not solve my problem.
View 6 Replies
View Related
May 3, 2012
I use ACA 2012 for residential design - I have a wall style, 2x4 stud w/ 1.5" airspace and 3.5" brick (modified from the stock styles) - but whenever I insert a window, it makes it as wide as the wall (9") when it should be only the depth of the stud wall (2x4 or 2x6) - How can I fix this?
View 7 Replies
View Related
Aug 16, 2012
Mostly I create door/window assemblies from an elevation sketch. I make sure that the DW tool on the tool palette has all the attributes I want for the new DW. Problem is that most times the attributes do not travel across to the new DW. I have a double hinged frameless door that I want as an override assignment.
And although the infill panel style has been defined in the DW style, when I use the infill panel override assignment, the double door style is not available from the drop down box. I have copied and assigned the DW to a new style, saved - closed - opened the drawing, but the double door style is still not available in the drop down box.
View 7 Replies
View Related
Sep 15, 2011
I am having a nagging problem related to window and door cleanups in walls. Certain walls seem to lose the opening for a window or door. Sometimes, disconnecting a wall from another at a T or L insection clears the problem, but when they meet again, the all openings in that wall disappear. It looks fine in plan view, but 3d aspects of the wall are affected. This problem is also inconsistant. Quite frustrating. I've a attached a series of jpegs that illustrate a current issue.
View 1 Replies
View Related
Jul 24, 2011
How to make aluminum frame glass door. How would you create the glass panel wall?
View 4 Replies
View Related